Skip to main content
PURPOSE The aim of this study was to evaluate maxillary full-arch implant-supported fixed rehabilitations by identifying biologic complications, implant survival and success rates, and patient satisfaction with treatment. In addition, the... more
PURPOSE The aim of this study was to evaluate maxillary full-arch implant-supported fixed rehabilitations by identifying biologic complications, implant survival and success rates, and patient satisfaction with treatment. In addition, the study verified the influence of attendance at maintenance appointments on the occurrence of complications. MATERIALS AND METHODS Data were collected from clinical follow-up appointments. RESULTS The sample consisted of 52 patients (363 implants) with follow-up of 1 to 12 years (mean: 4.69). The main biologic complication was soft tissue recession (20.8%) at the implant level. Tissue hyperplasia was observed in eight patients (15.4%), and 17 (4.7%) implants had bone loss ≥ 2 mm. The peri-implantitis rate was 3.1% (11 implants). Implant survival and success rates were 97.8% and 93.4%, respectively. Rates of patient satisfaction with treatment were as follows: 21 (40.4%) completely satisfied, 28 (53.8%) satisfied with some complaint, and 3 (5.8%) expe...
To evaluate the effect of an additional hydrophobic resin coating (HE) on the resin-dentine microtensile bond strengths (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of three universal adhesives used in the... more
To evaluate the effect of an additional hydrophobic resin coating (HE) on the resin-dentine microtensile bond strengths (μTBS), nanoleakage (NL), and in situ degree of conversion (DC) of three universal adhesives used in the etch-and-rinse (ER) and the self-etch (SE) modes. Sixty caries-free extracted third molars were divided into 12 groups according to the combination of the factors adhesive (All-Bond Universal [ABU]; G-Bond Plus [GBP] and Scotchbond Universal [SBU]), adhesive strategy (ER and SE), and the use of HE (Heliobond; yes or no). After restorations were constructed, specimens were stored in water (37°C/24h) and sectioned into resin-dentine beams (0.8mm(2)) to be tested under tension (0.5mm/min). Selected beams from each tooth were used for DC quantification and for NL evaluation. Data from each adhesive were analyzed with two-way ANOVA and Tukey's test (α=0.05). ABU and GBP resulted in higher μTBS in the ER mode. The use of HE increased the μTBS of ABU and GBP only i...
To evaluate the dentine microtensile bond strength (μTBS), nanoleakage (NL), degree of conversion (DC) within the hybrid layer for etch-and-rinse and self-etch strategies of universal simplified adhesive systems. forty caries free... more
To evaluate the dentine microtensile bond strength (μTBS), nanoleakage (NL), degree of conversion (DC) within the hybrid layer for etch-and-rinse and self-etch strategies of universal simplified adhesive systems. forty caries free extracted third molars were divided into 8 groups for μTBS (n=5), according to the adhesive and etching strategy: Clearfil SE Bond [CSE] and Adper Single Bond 2 [SB], as controls; Peak Universal Adhesive System, self-etch [PkSe] and etch-and-rinse [PkEr]; Scotchbond Universal Adhesive, self-etch [ScSe] and etch-and-rinse [ScEr]; All Bond Universal, self-etch [AlSe] and etch-and-rinse [AlEr]. After restorations were constructed, specimens were stored in water (37°C/24h) and then resin-dentine sticks were prepared (0.8mm(2)). The sticks were tested under tension at 0.5mm/min. Some sticks from each tooth group were used for DC determination by micro-Raman spectroscopy or nanoleakage evaluation (NL). The pH for each solution was evaluated using a pH metre. Data were analyzed with one-way ANOVA and Tukey's test (α=0.05). For μTBS, only PkSe and PkEr were similar to the respective control groups (p>0.05). AlSe showed the lowest μTBS mean (p<0.05). For NL, ScEr, ScSe, AlSe, and AlEr showed the lowest NL similar to control groups (p<0.05). For DC, only ScSe showed lower DC than the other materials (p<0.05). Performance of universal adhesives was shown to be material-dependent. The results indicate that this new category of universal adhesives used on dentine as either etch-and-rinse or self-etch strategies were inferior as regards at least one of the properties evaluated (μTBS, NL and DC) in comparison with the…
Research Interests: