Saldarriaga Vargas et al., 2018 - Google Patents

The challenges in the estimation of the effective dose when wearing radioprotective garments

Saldarriaga Vargas et al., 2018

Document ID
629062659657342220
Author
Saldarriaga Vargas C
Struelens L
Vanhavere F
Publication year
Publication venue
Radiation Protection Dosimetry

External Links

Snippet

The performance of a single or double dosimetry (SD or DD) algorithm on estimating effective dose wearing radioprotective garments (E RPG) depends on the specific irradiation conditions. This study investigates the photon energies and angles of incidence for which …
Continue reading at academic.oup.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T7/00Details of radiation-measuring instruments
    • G01T7/005Details of radiation-measuring instruments calibration techniques
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques

Similar Documents

Publication Publication Date Title
Farah et al. A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
Sonawane et al. Estimation of skin entrance doses (SEDs) for common medical X-ray diagnostic examinations in India and proposed diagnostic reference levels (DRLs)
Principi et al. Influence of dosemeter position for the assessment of eye lens dose during interventional cardiology
Clerinx et al. Double-dosimetry algorithm for workers in interventional radiology
Sanchez et al. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters
Häusler et al. Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
Principi et al. Eye lens dose in interventional cardiology
Hu et al. Shielding effect of lead glasses on radiologists’ eye lens exposure in interventional procedures
Siiskonen et al. Monte Carlo simulations of occupational radiation doses in interventional radiology
Manninen et al. The applicability of radiophotoluminescence dosemeter (RPLD) for measuring medical radiation (MR) doses
Saldarriaga Vargas et al. The challenges in the estimation of the effective dose when wearing radioprotective garments
Omar et al. On the feasibility of utilizing active personal dosimeters worn on the chest to estimate occupational eye lens dose in x-ray angiography
Silva et al. Energy and angular dependence of radiophotoluminescent glass dosemeters for eye lens dosimetry
Ginjaume et al. Effect of the radiation protective apron on the response of active and passive personal dosemeters used in interventional radiology and cardiology
Bordy et al. Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
Behrens et al. Influence of the phantom shape (slab, cylinder or alderson) on the performance of an H p (3) eye dosemeter
Young Dose rates in nuclear medicine and the effectiveness of lead aprons: updating the department’s knowledge on old and new procedures
Božović et al. Occupational eye lens dose estimated using whole-body dosemeter in interventional cardiology and radiology: A Monte Carlo study
Künzel et al. X‐ray spectroscopy in mammography with a silicon PIN photodiode with application to the measurement of tube voltage: X‐ray spectroscopy in mammography with a silicon photodiode
Clairand et al. Intercomparison of active personal dosemeters in interventional radiology
Čemusová et al. Assessment of eye lens doses in interventional radiology: a simulation in laboratory conditions
Schultz et al. Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters
Huda et al. Evaluation of staff, patient and foetal radiation doses due to endoscopic retrograde cholangiopancreatography (ERCP) procedures in a pregnant patient
Gonzales et al. Evaluation of mean conversion coefficients from air-kerma to H*(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range
Quintero-Quintero et al. Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures