Evaluation of mean conversion coefficients from air-kerma to H*(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range

Gonzales et al., 2016

View PDF
Document ID
9684093295882410582
Author
Gonzales A
Santos J
Mariano L
Tomal A
Costa P
Publication year
Publication venue
Journal of radiological protection

External Links

Snippet

Abstract Ambient dose equivalent H*(10) is an operational quantity recommended by the IAEA to establish dose constraints in area monitoring for external radiation. The direct measurement of H*(10) is not common due to the complexity in the calibration procedures of …
Continue reading at repositorio.usp.br (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N23/00Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
    • G01N23/02Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by transmitting the radiation through the material
    • GPHYSICS
    • G21NUCLEAR PHYSICS; NUCLEAR ENGINEERING
    • G21KTECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
    • G21K1/00Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
    • G21K1/02Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators

Similar Documents

Publication Publication Date Title
Hill et al. Advances in kilovoltage x-ray beam dosimetry
Monzen et al. Estimation of the shielding ability of a tungsten functional paper for diagnostic x‐rays and gamma rays
Abuhaimed et al. An assessment of the efficiency of methods for measurement of the computed tomography dose index (CTDI) for cone beam (CBCT) dosimetry by Monte Carlo simulation
Zhao et al. An indirect transmission measurement-based spectrum estimation method for computed tomography
Butler et al. High spatial resolution dosimetric response maps for radiotherapy ionization chambers measured using kilovoltage synchrotron radiation
Wagner et al. Use of a liquid ionization chamber for stereotactic radiotherapy dosimetry
Apostolakopoulos et al. Response of TL and OSL passive personal dosimetry systems in poly-energetic and multi-directional photon radiation fields
Ginjaume et al. Effect of the radiation protective apron on the response of active and passive personal dosemeters used in interventional radiology and cardiology
Gonzales et al. Evaluation of mean conversion coefficients from air-kerma to H*(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range
Wood et al. Validation of a technique for estimating organ doses for kilovoltage cone-beam CT of the prostate using the PCXMC 2.0 patient dose calculator
Takegami et al. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment
Carnicer et al. Study of the responses and calibration procedures of neutron and gamma area and environmental detectors for use in proton therapy
Santos et al. Evaluation of conversion coefficients relating air-kerma to H*(10) using primary and transmitted x-ray spectra in the diagnostic radiology energy range
Künzel et al. X‐ray spectroscopy in mammography with a silicon PIN photodiode with application to the measurement of tube voltage: X‐ray spectroscopy in mammography with a silicon photodiode
Santos et al. Normalized glandular dose (DgN) coefficients from experimental mammographic x-ray spectra
Quintero-Quintero et al. Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures
Sutton et al. The influence of patient size on the overall uncertainty in radiographic dose audit
Moore et al. A practical method to calibrate and optimise automatic exposure control devices for computed radiography (CR) and digital radiography (DR) imaging systems using the signal-to-noise ratio (SNR) metric
Araki et al. Ionization chamber dosimetry based on 60Co absorbed dose to water calibration for diagnostic kilovoltage x-ray beams
Macedo et al. Virtual Laboratory of Ionizing Radiation Metrology: Validation by spectrometry
Kumar et al. Dosimetric response of variable-size cavities in photon-irradiated media and the behaviour of the Spencer–Attix cavity integral with increasing Δ
Rindhatayathon et al. Investigating the impact of new dosimetric quantities recommended by ICRU 95 on the OSLD individual monitoring system at OAP, Thailand
Malusek et al. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter
Muñoz et al. Dosimetry in a mammography phantom using TLD‐300 dosimeters
Santos et al. Application of a semi-empirical model for the evaluation of transmission properties of barite mortar