Shang et al., 2013 - Google Patents
Teleoperation system with hybrid pneumatic-piezoelectric actuation for MRI-guided needle insertion with haptic feedbackShang et al., 2013
View PDF- Document ID
- 18104404221914097014
- Author
- Shang W
- Su H
- Li G
- Fischer G
- Publication year
- Publication venue
- 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems
External Links
Snippet
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with …
- 238000003780 insertion 0 title abstract description 25
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B2017/00017—Electrical control of surgical instruments
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/0059—Detecting, measuring or recording for diagnostic purposes; Identification of persons using light, e.g. diagnosis by transillumination, diascopy, fluorescence
- A61B5/0062—Arrangements for scanning
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B17/34—Trocars; Puncturing needles
- A61B17/3403—Needle locating or guiding means
- A61B2017/3405—Needle locating or guiding means using mechanical guide means
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
- A61B8/42—Details of probe positioning or probe attachment to the patient
- A61B8/4209—Details of probe positioning or probe attachment to the patient by using holders, e.g. positioning frames
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/45—For evaluating or diagnosing the musculoskeletal system or teeth
- A61B5/4528—Joints
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Shang et al. | Teleoperation system with hybrid pneumatic-piezoelectric actuation for MRI-guided needle insertion with haptic feedback | |
| Su et al. | An MRI-guided telesurgery system using a Fabry-Perot interferometry force sensor and a pneumatic haptic device | |
| US20210093304A1 (en) | Apparatus and methods for mri-compatible haptic interface | |
| Su et al. | Piezoelectrically actuated robotic system for MRI-guided prostate percutaneous therapy | |
| Stoianovici et al. | MRI-safe robot for endorectal prostate biopsy | |
| Eslami et al. | In‐bore prostate transperineal interventions with an MRI‐guided parallel manipulator: system development and preliminary evaluation | |
| Kulkarni et al. | Review of robotic needle guide systems for percutaneous intervention | |
| Elhawary et al. | The case for MR‐compatible robotics: a review of the state of the art | |
| Larson et al. | Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast | |
| Seifabadi et al. | Robotic system for MRI-guided prostate biopsy: feasibility of teleoperated needle insertion and ex vivo phantom study | |
| Goldenberg et al. | Robotic system for closed-bore MRI-guided prostatic interventions | |
| Nycz et al. | Mechanical validation of an MRI compatible stereotactic neurosurgery robot in preparation for pre-clinical trials | |
| Farooq et al. | A decade of MRI compatible robots: Systematic review | |
| US20090259122A1 (en) | Device and method for mri-guided breast interventions | |
| Patel et al. | Body-mounted robot for image-guided percutaneous interventions: mechanical design and preliminary accuracy evaluation | |
| Liang et al. | Magnetic resonance imaging-guided needle insertion robots: A review of systems for liver and kidney interventions | |
| Goldenberg et al. | Robot-assisted MRI-guided prostatic interventions | |
| Seifabadi et al. | Toward teleoperated needle steering under continuous MRI guidance for prostate percutaneous interventions | |
| Chen et al. | Closed loop control of an MR-conditional robot with wireless tracking coil feedback | |
| Su et al. | Sensors, actuators, and robots for MRI-guided surgery and interventions | |
| Hao et al. | High-field MRI-compatible needle placement robot for prostate interventions | |
| Li et al. | Development of an MRI-compatible needle driver for in-bore prostate biopsy | |
| Iranpanah et al. | A pneumatically actuated target stabilization device for MRI-guided breast biopsy | |
| Su et al. | Haptic system design for MRI-guided needle based prostate brachytherapy | |
| Su et al. | A networked modular hardware and software system for MRI-guided robotic prostate interventions |