Development of an MRI-compatible needle driver for in-bore prostate biopsy

Li et al., 2015

View PDF
Document ID
7561868382527974541
Author
Li M
Gonenc B
Kim K
Shang W
Iordachita I
Publication year
Publication venue
2015 International Conference on Advanced Robotics (ICAR)

External Links

Snippet

Minimally invasive percutaneous approaches routinely employ insertion of needles into soft tissue for diagnostic or therapeutic purposes. Lack of targeting accuracy while inserting needles can significantly mitigate the effectiveness of these methods. Robot-assisted needle …
Continue reading at pmc.ncbi.nlm.nih.gov (PDF) (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B17/34Trocars; Puncturing needles
    • A61B17/3403Needle locating or guiding means
    • A61B2017/3405Needle locating or guiding means using mechanical guide means
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B8/00Diagnosis using ultrasonic, sonic or infrasonic waves
    • A61B8/44Constructional features of the ultrasonic, sonic or infrasonic diagnostic device
    • A61B8/4444Constructional features of the ultrasonic, sonic or infrasonic diagnostic device related to the probe
    • A61B8/4461Features of the scanning mechanism, e.g. for moving the transducer within the housing of the probe
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B2017/00017Electrical control of surgical instruments
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B2017/00831Material properties
    • A61B2017/00902Material properties transparent or translucent
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B2017/00681Aspects not otherwise provided for
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B17/00234Surgical instruments, devices or methods, e.g. tourniquets for minimally invasive surgery
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61MDEVICES FOR INTRODUCING MEDIA INTO, OR ONTO, THE BODY; DEVICES FOR TRANSDUCING BODY MEDIA OR FOR TAKING MEDIA FROM THE BODY; DEVICES FOR PRODUCING OR ENDING SLEEP OR STUPOR
    • A61M25/00Catheters; Hollow probes
    • A61M25/01Introducing, guiding, advancing, emplacing or holding catheters
    • A61M25/0105Steering means as part of the catheter or advancing means; Markers for positioning
    • A61M25/0133Tip steering devices
    • A61M25/0136Handles therefor
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B1/00Instruments for performing medical examinations of the interior of cavities or tubes of the body by visual or photographical inspection, e.g. endoscopes; Illuminating arrangements therefor
    • A61B1/005Flexible endoscopes
    • A61B1/0051Flexible endoscopes with controlled bending of insertion part

Similar Documents

Publication Publication Date Title
US20240090881A1 (en) Apparatus and methods for mri-compatible haptic interface
US11751956B2 (en) Automated insertion device
Su et al. A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study
Monfaredi et al. MRI robots for needle-based interventions: systems and technology
Kulkarni et al. Review of robotic needle guide systems for percutaneous intervention
Fischer et al. MRI-compatible pneumatic robot for transperineal prostate needle placement
Fichtinger et al. Transrectal prostate biopsy inside closed MRI scanner with remote actuation, under real-time image guidance
Nycz et al. Mechanical validation of an MRI compatible stereotactic neurosurgery robot in preparation for pre-clinical trials
Taillant et al. CT and MR compatible light puncture robot: Architectural design and first experiments
Song et al. Design evaluation of a double ring RCM mechanism for robotic needle guidance in MRI-guided liver interventions
Mozer et al. Robotic image-guided needle interventions of the prostate
Patel et al. An integrated robotic system for MRI-guided neuroablation: Preclinical evaluation
Zemiti et al. LPR: A CT and MR-compatible puncture robot to enhance accuracy and safety of image-guided interventions
Dai et al. Image‐guided robots for low dose rate prostate brachytherapy: perspectives on safety in design and use
Musa et al. Minimally invasive intracerebral hemorrhage evacuation: a review
Matsui et al. Robotic systems in interventional oncology: a narrative review of the current status
Li et al. Development of an MRI-compatible needle driver for in-bore prostate biopsy
Patel et al. Robotic system for MRI-guided shoulder arthrography: Accuracy evaluation
Lafreniere et al. Design of an MRI-compatible robot for image-guided needle insertion procedures using active tendon-driven needles
Goldenberg et al. Robot-assisted MRI-guided prostatic interventions
Cole et al. Design of a robotic system for MRI-guided deep brain stimulation electrode placement
Fischer et al. Design of a robot for transperineal prostate needle placement in MRI scanner
Fischer et al. Pneumatically operated MRI-compatible needle placement robot for prostate interventions
Su et al. Haptic system design for MRI-guided needle based prostate brachytherapy
Kim et al. Development of a two DOF needle driver for CT-guided needle insertion-type interventional robotic system