Brain microdialysis is an analytical technique used for the dynamic monitoring of brain neurochem... more Brain microdialysis is an analytical technique used for the dynamic monitoring of brain neurochemistry in awake, freely moving animals. This technique requires the insertion of a small dialysis catheter, called a microdialysis probe, into a specific brain region, and its perfusion with an artificial extracellular fluid. The microdialysate samples, obtained from the probe outlet, can be analysed using high-performance liquid chromatography with electrochemical detection for the quantification of oxidizable molecules recovered from the extracellular space. In this chapter, we describe a protocol for performing a microdialysis setup and experiment in freely moving rats and mice. Furthermore, the high-performance liquid chromatographic determination of ascorbic acid, uric acid, catecholamines, indolamines and derivatives is described in detail.
A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is pres... more A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.
A novel dual channel in vitro apparatus, derived from a previously described design, has been cou... more A novel dual channel in vitro apparatus, derived from a previously described design, has been coupled with dopamine (DA) microsensors for the flow-through detection of DA secreted from PC12 cells. The device, including two independent microdialysis capillaries, was loaded with a solution containing PC12 cells while a constant phosphate-buffered saline (PBS) medium perfusion was carried out using a dual channel miniaturized peristaltic pump. One capillary was perfused with normal PBS, whereas extracellular calcium was removed from extracellular fluid of the second capillary. After a first period of stabilization and DA baseline recording, KCl (75 mM) was added to the perfusion fluid of both capillaries. In this manner, a simultaneous "treatment-control" experimental design was performed to detect K+-evoked calcium-dependent DA secretion. For this purpose, self-referencing DA microsensors were developed, and procedures for making, testing, and calibrating them are described in detail. The electronic circuitry was derived from previously published schematics and optimized for dual sensor constant potential amperometry applications. The microdialysis system was tested and validated in vitro under different experimental conditions, and DA secretion was confirmed by high-performance liquid chromatography with electrochemical detection (HPLC-EC). PC12 cell viability was quantified before and after each experiment. The proposed apparatus serves as a reliable model for studying the effects of different drugs on DA secretion through the direct comparison of extracellular DA increase in treatment-control experiments performed on the same initial PC12 cell population.
A new bidirectional telemetry system for amperometric sensor applications has been developed. A f... more A new bidirectional telemetry system for amperometric sensor applications has been developed. A fully automated peripheral unit (PU), constituted by a potentiostat, a two-channel I/V converter, a microcontroller unit (MCU) and a signal transmitter, was designed, constructed, and tested. A peripheral interface controller (PIC) MCU drives a digital-to-analog converter (DAC), which polarized the sensor, while the resulting anodic current is
Brain microdialysis is an analytical technique used for the dynamic monitoring of brain neurochem... more Brain microdialysis is an analytical technique used for the dynamic monitoring of brain neurochemistry in awake, freely moving animals. This technique requires the insertion of a small dialysis catheter, called a microdialysis probe, into a specific brain region, and its perfusion with an artificial extracellular fluid. The microdialysate samples, obtained from the probe outlet, can be analysed using high-performance liquid chromatography with electrochemical detection for the quantification of oxidizable molecules recovered from the extracellular space. In this chapter, we describe a protocol for performing a microdialysis setup and experiment in freely moving rats and mice. Furthermore, the high-performance liquid chromatographic determination of ascorbic acid, uric acid, catecholamines, indolamines and derivatives is described in detail.
A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is pres... more A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.
A novel dual channel in vitro apparatus, derived from a previously described design, has been cou... more A novel dual channel in vitro apparatus, derived from a previously described design, has been coupled with dopamine (DA) microsensors for the flow-through detection of DA secreted from PC12 cells. The device, including two independent microdialysis capillaries, was loaded with a solution containing PC12 cells while a constant phosphate-buffered saline (PBS) medium perfusion was carried out using a dual channel miniaturized peristaltic pump. One capillary was perfused with normal PBS, whereas extracellular calcium was removed from extracellular fluid of the second capillary. After a first period of stabilization and DA baseline recording, KCl (75 mM) was added to the perfusion fluid of both capillaries. In this manner, a simultaneous "treatment-control" experimental design was performed to detect K+-evoked calcium-dependent DA secretion. For this purpose, self-referencing DA microsensors were developed, and procedures for making, testing, and calibrating them are described in detail. The electronic circuitry was derived from previously published schematics and optimized for dual sensor constant potential amperometry applications. The microdialysis system was tested and validated in vitro under different experimental conditions, and DA secretion was confirmed by high-performance liquid chromatography with electrochemical detection (HPLC-EC). PC12 cell viability was quantified before and after each experiment. The proposed apparatus serves as a reliable model for studying the effects of different drugs on DA secretion through the direct comparison of extracellular DA increase in treatment-control experiments performed on the same initial PC12 cell population.
A new bidirectional telemetry system for amperometric sensor applications has been developed. A f... more A new bidirectional telemetry system for amperometric sensor applications has been developed. A fully automated peripheral unit (PU), constituted by a potentiostat, a two-channel I/V converter, a microcontroller unit (MCU) and a signal transmitter, was designed, constructed, and tested. A peripheral interface controller (PIC) MCU drives a digital-to-analog converter (DAC), which polarized the sensor, while the resulting anodic current is