Electronic Supplementary Material (ESI) for Nanoscale.
This journal is © The Royal Society of Chemistry 2018
Supplementary Information
Bottom-up Meets Top-down: Tailored Raspberry-like Fe3O4-Pt
Nanocrystal Superlattices
Fen Qiu,a † René H. J. Vervuurt,b † Marcel A. Verheijen,b,c Edmond W. Zaia,a,d Erin B. Creel,a,d
Youngsang Kim,a Jeffrey J. Urban,*a Ageeth A. Bol*b
Table of contents
1. Experimental Section
1.1. Synthesis of Fe3O4
1.2. Self-assembly of Fe3O4 superlattices
1.3. Atomic Layer Deposition
1.4. TEM
1.5. STEM
1.6. X-ray Photoelectron Spectroscopy
1.7. Fabrication of Electrode
1.8. Photocurrent measurement
1.9. IPCE measurement
1. Experimental Section
1.1. Synthesis of Fe3O4: Fe3O4 NPs were synthesized under argon atmosphere using standard
Schlenk line techniques according to the literature method.[1]
1.2. Self-assembly of Fe3O4 superlattices: a solution of Fe3O4 NPs was drop-cast onto the
surface of diethylene glycol (DEG) in a Teflon well swiftly, and covered with glass to ensure a
slow evaporation of solvent form a film. Silicon monoxide TEM grids were used here for
transferring the fluid supported film upon drying of the NP solvent for the studies in this report.
1.3. Atomic Layer Deposition: Pt was deposited on the Fe3O4 super lattices by ALD, in a
home-built ALD reactor equipped with an inductively coupled plasma (ICP) source.[2] The base
pressure of the system was ~10-6 mbar. Before ALD the Fe3O4 particles were cleaned by a 3
min O2 plasma exposure (0.01 mbar, 100W), to remove any remaining oleylamine and oleic acid
ligands form the Fe3O4 super lattice synthesis process. Due to carbon build up on the samples
as a result of air exposure, it is difficult to confirm the removal of these ligands with any ex-situ
technique, for example, XPS. It should be noted that without O2 pre-treatment no uniform Pt
particle growth on the Fe3O4 was obtained, which is an indirect proof that some, if not all carbon
has been removed. Additionally, without O2 pre-treatment a low contrast (low-atomic number)
shell could sometimes be observed around the particles in TEM, possibly indicating the
remnants of the ligand molecules, shown in Figure S7 in SI After plasma treatment this shell
was no longer observed and the Pt growth was uniform across the sample.
The Pt ALD process consisted of a 4 s MeCpPtMe3 precursor dose and a 5 s O2 gas reaction
step, separated by pump steps. The table temperature was set to 300 °C, while the reactor walls
were kept at 100 °C. The effective sample temperature during deposition was approximately 120
°C, as determined by in-situ spectroscopic ellipsometry (SE) using a Si reference sample. The O2
pressure during the reaction step was 0.01 mbar. The relatively low pressure during Pt deposition
results in a poor thermal contact between the substrates used and the table heater. The effective
sample temperature is therefore much lower than 300 °C and closer 120 °C, as determined by insitu spectroscopic ellipsometry (SE) using a Si reference sample. The low sample temperature
prevents Pt growth on the SiO2 substrates, making the selective deposition of Pt on Fe3O4
possible.[3] This is because the thermal energy is insufficient to dissociate O2 and remove the
MeCpPtMe3 precursor ligands in the O2 half cycle on SiO2.[4] Pt growth does occur on the Fe3O4
particles, most likely due to its catalytic properties, such as its ability to dissociate H2O.[5] For some
of the experiments the Pt ALD deposition was interrupted by a 3 min O2 Plasma exposure (0.01
mbar, 100W) to remove surface carbon that accumulated on the Pt and Fe3O4 during growth.
1.4. Transmission electron microscope (TEM): TEM images were acquired on an CM200
operated at 200 keV.
1.5. Scanning transmission electron microscope (STEM): After Pt ALD the samples were
analyzed by a JEOL ARM 200 probe corrected STEM, operated at 200 kV. The images were
acquired in high angle annular dark field (HAADF) mode. The Pt particle size was determined by
analyzing several (minimum of 3 per sample) HAAFD STEM images using the Image J software
package.
1.6. X-ray Photoelectron Spectroscopy: X-ray Photoelectron Spectroscopy (XPS) was used to
investigate the electronic structure of the Pt-Fe3O4 composite nanoparticle system. Specifically,
the Pt 4f and Fe 2p core levels were probed. A PHI 5400 X-ray Photoelectron Spectroscopy (XPS)
System with a conventional Mg Kα source operated at 350 W was used for this purpose. Pass
energy of 20 eV was used for narrow scan spectra, corresponding to an energy resolution of ~700
meV. All peak positions were referenced to the C 1s of 284.5 eV.
1.7. Fabrication of Electrode: A circular glass substrate (19 mm diameter and 0.5 mm thick,
ProSciTech) was cleaned using solvents (acetone and isopropyl alcohol) followed by ultrapure
water (Milli-Q) then air plasma (for 3 min). The air plasma cleaning enhances the adhesion of
metals on the glass. Ag and Ti was deposited using an e-beam evaporator through a shadow
mask having a dumbbell-like shape, where Ti (3 nm thick) is used to promote the adhesion of Ag
thin film (100 nm thick) to the glass. Subsequently, on top of Ag thin film, TiO2 film (80 nm thick)
was deposited using an e-beam evaporator except the contact area. The substrate temperature
kept 350˚C while depositing TiO2.
1.8. Photocurrent measurement: We have built a highly sensitive photocurrent measurement
setup for the electrochemical cell system using the lock-in technique. A sample immersed in a
glass electrochemical cell with a quartz window is illuminated by a light source (Xe lamp, ~ 850
mW/cm2) through a condenser lens (transmission: 350 nm – 700 nm) and a chopper. The light
chopping (3 Hz) is synchronized with a lock-in amplifier (SRS 850) to lock-in the square wave of
modulated photocurrent generated by the chopped light. The lock-in amplifier is also linked with
a potentiostat (BioLogic SP-200). The lock-in amplifier generates the r.m.s. amplitude of the first
harmonic of the signal, which is the photocurrent. In this manner, we can measure the amplitude
of photocurrent while sweeping the potential applied to the working electrode. The condenser lens
that blocks IR wavelengths and the light chopping in a short period rule out any heating effect on
the surface of our samples.
1.9. IPCE measurements: Incident to photon-to-current efficiency (IPCE) is a potentialdependent measurement of how efficiently photons of a given wavelength are converted to charge
transfer in an electrochemical cell (three electrode configuration). A highly-sensitive IPCE setup
was built incorporating the lock-in technique with a potentiostat (Biologic SP-200) and a
monochromator (Oriel Cornerstone 130). A visible wavelength of light from a Xe lamp is selected
by a monochromator and illuminates the photoelectrode surface through a chopper. The on and
off pattern of illumination created by the chopper generates a 3 Hz square wave signal which is
fed into the lock-in amplifier for enhanced signal-to-noise ratio. The photocurrent of a Si
photodiode is measured as a reference for photon density. IPCE was measured for each sample
type at visible wavelengths in 10 nm increments for a series of chronoamperometric scans at
various potentials. Figure S5 shows IPCE results measured in Ar-saturated 1M NaOH at 0.4 V vs
Ag/AgCl.
Figure S1 TEM and FFT of Fe3O4 NP Superlattices
Figure S2 Scanning transmission electron microscopy (STEM) of Fe3O4 NP Superlattices
formed by drop casting
Figure S3 High angle annular dark field (HAADF) high resolution scanning transmission electron
microscopy (HR-STEM) images of NPs after 10, 30, 50, 100, 200 and 500 Pt ALD cycles
respectively.
Figure S4 Chronoamperometry with chopped-light illumination (3 Hz). Current was recorded at a
constant potential 0.2 V vs. Ag/AgCl with in Ar-satuated 1 M NaOH
Figure S5 IPCE of Ag-TiO2-Pt and Ag-TiO2-Fe3O4-Pt with 250 cycles and 500 cycles of ALD
Figure S6 Durability Test of Dark and Light Current Density of Ag-TiO2-Fe3O4-Pt Composites for
1000 Seconds (The inset is the photocurrent)
Figure S7 High angle annular dark field (HAADF) high resolution scanning transmission electron
microscopy (HR-STEM) images of NPs 500 Pt ALD cycles. In this case the O2 plasma treatment
was insufficient to fully clean the samples. A low contrast (low atomic number) shell can be
observed around the Fe3O4 particles.
References
[1]
[2]
[3]
[4]
[5]
J. Park, K. J. An, Y. S. Hwang, J. G. Park, H. J. Noh, J. Y. Kim, J. H. Park, N. M. Hwang,
T. Hyeon, Nature Materials 2004, 3, 891-895.
H. C. M. Knoops, A. J. M. Mackus, M. E. Donders, M. C. M. van de Sanden, P. H. L.
Notten, W. M. M. Kessels, Electrochemical and Solid State Letters 2009, 12, G34-G36.
A. J. M. Mackus, S. A. F. Dielissen, J. J. L. Mulders, W. M. M. Kessels, Nanoscale 2012,
4, 4477-4480.
A. J. M. Mackus, N. Leick, L. Baker, W. M. M. Kessels, Chem Mater 2012, 24, 17521761.
N. Mulakaluri, R. Pentcheva, M. Scheffler, J Phys Chem C 2010, 114, 11148-11156.