[go: up one dir, main page]

Ertürk et al., 2017 - Google Patents

The effect of 2 different surgical methods on intracompartmental pressure value in tibial shaft fracture: An experimental study in a rabbit model

Ertürk et al., 2017

View HTML
Document ID
8644576098739741064
Author
Ertürk C
Altay M
Altay N
Öztürk Ä
Baykara Ä
Sert C
Işıkan U
Publication year
Publication venue
Turkish Journal of Trauma and Emergency Surgery

External Links

Snippet

BACKGROUND: Intracompartmental pressure (ICP) monitoring is a widely used modality, particularly after intramedullary nailing of tibial shaft fractures. It was hypothesized that ICP value in fracture fixed with Ilizarov circular fixator (ICF) might be lower than in fracture fixed …
Continue reading at jag.journalagent.com (HTML) (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B17/56Surgical instruments or methods for treatment of bones or joints; Devices specially adapted therefor
    • A61B17/58Surgical instruments or methods for treatment of bones or joints; Devices specially adapted therefor for osteosynthesis, e.g. bone plates, screws, setting implements or the like
    • A61B17/68Internal fixation devices, including fasteners and spinal fixators, even if a part thereof projects from the skin
    • A61B17/74Devices for the head or neck or trochanter of the femur
    • A61B17/742Devices for the head or neck or trochanter of the femur having one or more longitudinal elements oriented along or parallel to the axis of the neck
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B17/00Surgical instruments, devices or methods, e.g. tourniquets
    • A61B17/56Surgical instruments or methods for treatment of bones or joints; Devices specially adapted therefor
    • A61B17/58Surgical instruments or methods for treatment of bones or joints; Devices specially adapted therefor for osteosynthesis, e.g. bone plates, screws, setting implements or the like
    • A61B17/68Internal fixation devices, including fasteners and spinal fixators, even if a part thereof projects from the skin
    • A61B17/80Cortical plates, i.e. bone plates; Instruments for holding or positioning cortical plates, or for compressing bones attached to cortical plates
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/48Other medical applications

Similar Documents

Publication Publication Date Title
Wolf et al. Effects of high-frequency, low-magnitude mechanical stimulus on bone healing
Gormeli et al. Comparison of femur intertrochanteric fracture fixation with hemiarthroplasty and proximal femoral nail systems
Bales et al. The effects of surgical delay on the outcome of pediatric supracondylar humeral fractures
Kashid et al. Comparative study between proximal femoral nail and proximal femoral nail antirotation in management of unstable trochanteric fractures
Könning et al. A comparison between fixation methods of femoral diaphyseal fractures in cats–a retrospective study
Ertürk et al. The effect of 2 different surgical methods on intracompartmental pressure value in tibial shaft fracture: An experimental study in a rabbit model
Shaha et al. Redefining optimal nail to medullary canal diameter ratio in stainless steel flexible intramedullary nailing of pediatric femur fractures
Uzer et al. Comparison of two types of proximal femoral hails in the treatment of intertrochanteric femur fractures
Schemitsch et al. Function plateaus by one year in patients with surgically treated displaced midshaft clavicle fractures
Ward et al. Injury to the superior gluteal artery during intramedullary fixation of an atypical subtrochanteric stress fracture: a case report
Ertürk et al. Tibia cisim kırıklarında iki farklı cerrahi yöntemin kompartman basıncı üzerine etkisi: Tavşan modelinde deneysel bir çalışma
Küçükdurmaz et al. A newly designed intramedullary nail with distal interlocking system for tibia fractures in adults-the clinical results
Challis et al. Cyclic pneumatic soft-tissue compression accelerates the union of distal radial osteotomies in an ovine model
Kim et al. Subcapital femoral neck fracture after treatment of an intertrochanteric fracture with proximal femoral intramedullary nail
Günay et al. Which modality is the best choice in distal radius fractures treated with two different Kirschner wire fixation and immobilization techniques?
Sönmez et al. Minimal invasive fixation of distal tibial fractures does not result in rotational malalignment: A report of 24 cases with CT imaging
RU155662U1 (en) COMPRESSING SCREW
Peng et al. Did you notice the tibial nutrient artery when applying external fixation?
Chandra et al. A study on internal fixation of compound fractures of tibia using interlocking nail without reaming
Ishak et al. The effect of cannulated hip screw size in the treatment of femoral neck fracture
Guo et al. Letter regarding article by li AB et al.: intramedullary and extramedullary fixations for the treatment of unstable femoral intertrochanteric fractures: a meta-analysis of prospective randomized controlled trials
Andalib et al. Comparison of the results of fixation of reverse-oblique intertrochanteric and short-segment subtrochanteric fractures using dynamic hip screw (DHS) and dynamic condylar screw (DCS)
Wilson et al. Polyether Ether Ketone (PEEK) Carbon Fiber Composites May Improve Healing of Fractures Stabilized with Intramedullary Nails
Vaidyanathan et al. Evaluation of a Novel Immediate Graded Weight-bearing Protocol and its Effect on the Formation of Fracture Callus in Femoral Shaft Fractures Fixed with Intramedullary Interlocking Nails: A Prospective Interventional Cohort Study
Ertürk et al. The use of Ender nail in intertrochanteric fractures supported with external fixation