Dennerlein et al., 2012 - Google Patents
Geometric jitter compensation in cone-beam CT through registration of directly and indirectly filtered projectionsDennerlein et al., 2012
- Document ID
- 8011910111878531280
- Author
- Dennerlein F
- Jerebko A
- Publication year
- Publication venue
- 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)
External Links
Snippet
We present an iterative method for reducing the blurring and roughness artifacts in cone- beam CT reconstructions that are caused by unknown geometric jitter. Geometric uncertainties are estimated by registering directly and indirectly filtered projections. We …
- 230000003247 decreasing 0 abstract description 6
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/006—Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10104—Positron emission tomography [PET]
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
- G06T2211/424—Iterative
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
- G06T2211/416—Exact reconstruction
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/507—Clinical applications involving determination of haemodynamic parameters, e.g. perfusion CT
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/52—Devices using data or image processing specially adapted for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
Similar Documents
Publication | Publication Date | Title |
---|---|---|
EP2410491B1 (en) | System and method for reconstruction of X-ray images | |
US8879814B2 (en) | Method and apparatus for reducing motion related imaging artifacts using consistency values | |
Abella et al. | Software architecture for multi-bed FDK-based reconstruction in X-ray CT scanners | |
KR101473538B1 (en) | Extracting patient motion vectors from marker positions in x-ray images | |
Sun et al. | An iterative projection‐based motion estimation and compensation scheme for head x‐ray CT | |
Choi et al. | Fiducial marker‐based correction for involuntary motion in weight‐bearing C‐arm CT scanning of knees. Part I. Numerical model‐based optimization | |
Yu et al. | Data consistency based translational motion artifact reduction in fan-beam CT | |
AU2019271915A1 (en) | Method and system for motion correction in CT imaging | |
US20110082368A1 (en) | Reconstruction of dynamical cardiac spect for measuring tracer uptake and redistribution | |
WO2018040126A1 (en) | Tomosynthesis image reconstruction method and system | |
US9592021B2 (en) | X-ray CT device, and method | |
Niebler et al. | Projection‐based improvement of 3D reconstructions from motion‐impaired dental cone beam CT data | |
US10039512B2 (en) | Image quality in computed tomography using redundant information in production data sets | |
Dennerlein et al. | Geometric jitter compensation in cone-beam CT through registration of directly and indirectly filtered projections | |
Faber et al. | Motion correction of pet brain images through deconvolution: I. theoretical development and analysis in software simulations | |
Van Den Heuvel et al. | Attenuation correction of PET activation studies in the presenceof task-related motion | |
Manhart et al. | Fast dynamic reconstruction algorithm with joint bilateral filtering for perfusion C-arm CT | |
US20100254585A1 (en) | Overexposure correction for large volume reconstruction in computed tomography apparatus | |
CN102764135B (en) | Heart axial movement correcting method for myocardium SPECT (single photon emission computed tomography) perfusion imaging | |
Rausch et al. | Kinect‐Based Correction of Overexposure Artifacts in Knee Imaging with C‐Arm CT Systems | |
US20230148983A1 (en) | Suppression of motion artifacts in computed tomography imaging | |
CN113229840B (en) | Oral CBCT (cone beam computed tomography) shot image motion compensation reconstruction method | |
Bhowmik et al. | Mitigating motion artifacts in FDK based 3D cone-beam brain imaging system using markers | |
Lamare et al. | Incorporation of elastic transformations in list-mode based reconstruction for respiratory motion correction in PET | |
Syben et al. | Self-Calibration and Simultaneous Motion Estimation for C-Arm CT Using Fiducial |