Mahato et al., 2017 - Google Patents
Quantification of intervertebral displacement with a novel MRI-based modeling technique: assessing measurement bias and reliability with a porcine spine modelMahato et al., 2017
- Document ID
- 8006501268326319661
- Author
- Mahato N
- Montuelle S
- Goubeaux C
- Cotton J
- Williams S
- Thomas J
- Clark B
- Publication year
- Publication venue
- Magnetic Resonance Imaging
External Links
Snippet
The purpose of this study was to develop a novel magnetic resonance imaging (MRI)-based modeling technique for measuring intervertebral displacements. Here, we present the measurement bias and reliability of the developmental work using a porcine spine model …
- 238000006073 displacement reaction 0 title abstract description 98
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/45—For evaluating or diagnosing the musculoskeletal system or teeth
- A61B5/4528—Joints
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/055—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves involving electronic or nuclear magnetic resonance, e.g. magnetic resonance imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/103—Detecting, measuring or recording devices for testing the shape, pattern, colour, size or movement of the body or parts thereof, for diagnostic purposes
- A61B5/11—Measuring movement of the entire body or parts thereof, e.g. head or hand tremor, mobility of a limb
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/30—Subject of image; Context of image processing
- G06T2207/30004—Biomedical image processing
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/70—Means for positioning the patient in relation to the detecting, measuring or recording means
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/52—Devices using data or image processing specially adapted for radiation diagnosis
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T7/00—Image analysis
- G06T7/0002—Inspection of images, e.g. flaw detection
- G06T7/0012—Biomedical image inspection
- G06T7/0014—Biomedical image inspection using an image reference approach
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Whittier et al. | Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography | |
Quijano et al. | Three-dimensional reconstruction of the lower limb from biplanar calibrated radiographs | |
Moro‐oka et al. | Can magnetic resonance imaging–derived bone models be used for accurate motion measurement with single‐plane three‐dimensional shape registration? | |
Schumann et al. | X-ray image calibration and its application to clinical orthopedics | |
Sharma et al. | Radiological method for measuring patellofemoral tracking and tibiofemoral kinematics before and after total knee replacement | |
Rebmann et al. | Precise 3D skeletal kinematics using fast phase contrast magnetic resonance imaging | |
WO2020044345A1 (en) | Correcting motion-related distortions in radiographic scans | |
Lin et al. | Comparisons of surface vs. volumetric model-based registration methods using single-plane vs. bi-plane fluoroscopy in measuring spinal kinematics | |
Anderst et al. | A technique to measure three-dimensional in vivo rotation of fused and adjacent lumbar vertebrae | |
Ackland et al. | Future trends in the use of X-ray fluoroscopy for the measurement and modelling of joint motion | |
Lin et al. | Intervertebral anticollision constraints improve out‐of‐plane translation accuracy of a single‐plane fluoroscopy‐to‐CT registration method for measuring spinal motion | |
Zhang et al. | Investigation of 3D glenohumeral displacements from 3D reconstruction using biplane X-ray images: accuracy and reproducibility of the technique and preliminary analysis in rotator cuff tear patients | |
Maier et al. | Rigid and non-rigid motion compensation in weight-bearing CBCT of the knee using simulated inertial measurements | |
Mahato et al. | Quantification of intervertebral displacement with a novel MRI-based modeling technique: assessing measurement bias and reliability with a porcine spine model | |
Jerbi et al. | 2-D–3-D frequency registration using a low-dose radiographic system for knee motion estimation | |
Moura et al. | A flexible approach for the calibration of biplanar radiography of the spine on conventional radiological systems | |
Mahato et al. | Development of a morphology-based modeling technique for tracking solid-body displacements: examining the reliability of a potential MRI-only approach for joint kinematics assessment | |
Koo et al. | A non-ionizing technique for three-dimensional measurement of the lumbar spine | |
US9743879B2 (en) | Kinematic analysis based on MRI bone marrow signals | |
Mahato et al. | Assessment of in vivo lumbar inter-vertebral motion: reliability of a novel dynamic weight-bearing magnetic resonance imaging technique using a side-bending task | |
Tuijthof et al. | Accuracy of a CT-based bone contour registration method to measure relative bone motions in the hindfoot | |
Berry et al. | An endplate-based joint coordinate system for measuring kinematics in normal and abnormally-shaped lumbar vertebrae | |
Olender et al. | Validation of an anatomical coordinate system for clinical evaluation of the knee joint in upright and closed MRI | |
JP4572294B2 (en) | Image processing program and image processing method | |
Choplin et al. | Skeletal Imaging |