Clarke et al., 1939 - Google Patents
Overvoltages during power-system faultsClarke et al., 1939
- Document ID
- 7606115662292907845
- Author
- Clarke E
- Crary S
- Peterson H
- Publication year
- Publication venue
- Electrical Engineering
External Links
Snippet
OVERVOLTAGES may be produced by lightning, switching surges, faults, both solid and arcing, and the overspeeding of machines due to loss of load. The effect of circuit and machine characteristics on the duration and magnitude of these overvoltages has received …
- 230000000694 effects 0 abstract description 27
Classifications
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H3/00—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
- H02H3/26—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents
- H02H3/32—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors
- H02H3/33—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors using summation current transformers
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H7/00—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
- H02H7/04—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions for transformers
- H02H7/045—Differential protection of transformers
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H3/00—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
- H02H3/26—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents
- H02H3/28—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at two spaced portions of a single system, e.g. at opposite ends of one line, at input and output of apparatus
- H02H3/30—Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at two spaced portions of a single system, e.g. at opposite ends of one line, at input and output of apparatus using pilot wires or other signalling channel
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H7/00—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
- H02H7/26—Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H7/00—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
- H02H7/06—Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions for dynamo-electric generators; for synchronous capacitors
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H9/00—Emergency protective circuit arrangements for limiting excess current or voltage without disconnection
- H02H9/08—Emergency protective circuit arrangements for limiting excess current or voltage without disconnection limitation or suppression of earth fault currents, e.g. Petersen coil
-
- H—ELECTRICITY
- H01—BASIC ELECTRIC ELEMENTS
- H01F—MAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
- H01F27/00—Details of transformers or inductances, in general
- H01F27/28—Coils; Windings; Conductive connections
- H01F27/32—Insulating of coils, windings, or parts thereof
- H01F2027/329—Insulation with semiconducting layer, e.g. to reduce corona effect
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H1/00—Details of emergency protective circuit arrangements
- H02H1/0007—Details of emergency protective circuit arrangements concerning the detecting means
-
- H—ELECTRICITY
- H02—GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
- H02H—EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
- H02H1/00—Details of emergency protective circuit arrangements
- H02H1/0038—Details of emergency protective circuit arrangements concerning the connection of the detecting means, e.g. for reducing their number
- H02H1/0053—Means for storing the measured quantities during a predetermined time
Similar Documents
Publication | Publication Date | Title |
---|---|---|
CN108318762B (en) | Method for judging power frequency ferromagnetic resonance of voltage transformer | |
Kameda et al. | Setting method of specific parameters of a superconducting fault current limiter considering the operation of power system protection-resistance-type and rectifier-type SFCLs in overhead transmission systems | |
Clarke et al. | Overvoltages during power-system faults | |
Nagpal et al. | Damaging open-phase overvoltage disturbance on a shunt-compensated 500-kV line initiated by unintended trip | |
US10224145B2 (en) | Earth surface potential and harmonic mitigating transformers | |
Borghetti et al. | Transient recovery voltages in vacuum circuit breakers generated by the interruption of inrush currents of large motors | |
Kimbark et al. | Fault surge versus switching surge a study of transient overvoltages caused by line-to-ground faults | |
EP0901706B1 (en) | A method and a device for reducing third harmonic phenomena in a rotating electric alternating current machine | |
CN119134245B (en) | A detuning device and method for suppressing ferromagnetic resonance in power system | |
da Costa et al. | Impact evaluation of the neutral-grounding resistance on short-duration rms voltage variations | |
Conwell et al. | The Petersen earth coil | |
Pillai et al. | Grounding and ground fault protection of multiple generator installations on medium-voltage industrial and commercial systems-Part 2: Grounding Methods Working Group report | |
Hunter | Some engineering features of Petersen coils and their application | |
Lambert et al. | Long line single-phase switching transients and their effect on station equipment | |
Folliot et al. | Neutral grounding reactor for medium voltage networks | |
Prusty et al. | Predetermination of lateral length to prevent overvoltage problems due to open conductors in three-phase systems | |
CN115483665B (en) | Low-frequency oscillation suppression wiring method and device for voltage transformer applied to power distribution network | |
Clerici et al. | Dynamic overvoltages and ferroresonance found in switching surge studies for Iran 400 kV system | |
Hardaway et al. | Test and operation of Petersen coil on 100-kv system of public service company of Colorado | |
Johnson et al. | Switching of Extra-High-Voltage Circuits I-System Requirements for Circuit Breakers | |
Buono et al. | Insulation Coordination Studies on the Future Italian 36 kV Network–Transient Overvoltages | |
Mortlock et al. | Neutral earthing of three-phase systems, with particular reference to large power stations | |
Rioual et al. | Energization of a no-load transformer for power restoration purposes: modeling and validation by on site tests | |
Johnson | Grounding principles and practice III—Generator-neutral grounding devices | |
da Costa et al. | Single-line-to-earth protection on noneffectively-earthed distribution systems through overvoltage-and undervoltage-based philosophies |