Clarke et al., 1939 - Google Patents

Overvoltages during power-system faults

Clarke et al., 1939

Document ID
7606115662292907845
Author
Clarke E
Crary S
Peterson H
Publication year
Publication venue
Electrical Engineering

External Links

Snippet

OVERVOLTAGES may be produced by lightning, switching surges, faults, both solid and arcing, and the overspeeding of machines due to loss of load. The effect of circuit and machine characteristics on the duration and magnitude of these overvoltages has received …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H3/00Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
    • H02H3/26Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents
    • H02H3/32Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors
    • H02H3/33Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors using summation current transformers
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/04Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions for transformers
    • H02H7/045Differential protection of transformers
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H3/00Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
    • H02H3/26Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents
    • H02H3/28Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at two spaced portions of a single system, e.g. at opposite ends of one line, at input and output of apparatus
    • H02H3/30Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at two spaced portions of a single system, e.g. at opposite ends of one line, at input and output of apparatus using pilot wires or other signalling channel
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/26Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/06Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions for dynamo-electric generators; for synchronous capacitors
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H9/00Emergency protective circuit arrangements for limiting excess current or voltage without disconnection
    • H02H9/08Emergency protective circuit arrangements for limiting excess current or voltage without disconnection limitation or suppression of earth fault currents, e.g. Petersen coil
    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01FMAGNETS; INDUCTANCES; TRANSFORMERS; SELECTION OF MATERIALS FOR THEIR MAGNETIC PROPERTIES
    • H01F27/00Details of transformers or inductances, in general
    • H01F27/28Coils; Windings; Conductive connections
    • H01F27/32Insulating of coils, windings, or parts thereof
    • H01F2027/329Insulation with semiconducting layer, e.g. to reduce corona effect
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H1/00Details of emergency protective circuit arrangements
    • H02H1/0007Details of emergency protective circuit arrangements concerning the detecting means
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H1/00Details of emergency protective circuit arrangements
    • H02H1/0038Details of emergency protective circuit arrangements concerning the connection of the detecting means, e.g. for reducing their number
    • H02H1/0053Means for storing the measured quantities during a predetermined time

Similar Documents

Publication Publication Date Title
CN108318762B (en) Method for judging power frequency ferromagnetic resonance of voltage transformer
Kameda et al. Setting method of specific parameters of a superconducting fault current limiter considering the operation of power system protection-resistance-type and rectifier-type SFCLs in overhead transmission systems
Clarke et al. Overvoltages during power-system faults
Nagpal et al. Damaging open-phase overvoltage disturbance on a shunt-compensated 500-kV line initiated by unintended trip
US10224145B2 (en) Earth surface potential and harmonic mitigating transformers
Borghetti et al. Transient recovery voltages in vacuum circuit breakers generated by the interruption of inrush currents of large motors
Kimbark et al. Fault surge versus switching surge a study of transient overvoltages caused by line-to-ground faults
EP0901706B1 (en) A method and a device for reducing third harmonic phenomena in a rotating electric alternating current machine
CN119134245B (en) A detuning device and method for suppressing ferromagnetic resonance in power system
da Costa et al. Impact evaluation of the neutral-grounding resistance on short-duration rms voltage variations
Conwell et al. The Petersen earth coil
Pillai et al. Grounding and ground fault protection of multiple generator installations on medium-voltage industrial and commercial systems-Part 2: Grounding Methods Working Group report
Hunter Some engineering features of Petersen coils and their application
Lambert et al. Long line single-phase switching transients and their effect on station equipment
Folliot et al. Neutral grounding reactor for medium voltage networks
Prusty et al. Predetermination of lateral length to prevent overvoltage problems due to open conductors in three-phase systems
CN115483665B (en) Low-frequency oscillation suppression wiring method and device for voltage transformer applied to power distribution network
Clerici et al. Dynamic overvoltages and ferroresonance found in switching surge studies for Iran 400 kV system
Hardaway et al. Test and operation of Petersen coil on 100-kv system of public service company of Colorado
Johnson et al. Switching of Extra-High-Voltage Circuits I-System Requirements for Circuit Breakers
Buono et al. Insulation Coordination Studies on the Future Italian 36 kV Network–Transient Overvoltages
Mortlock et al. Neutral earthing of three-phase systems, with particular reference to large power stations
Rioual et al. Energization of a no-load transformer for power restoration purposes: modeling and validation by on site tests
Johnson Grounding principles and practice III—Generator-neutral grounding devices
da Costa et al. Single-line-to-earth protection on noneffectively-earthed distribution systems through overvoltage-and undervoltage-based philosophies