Beam focal spot intrafraction motion and gantry angle dependence: a study of Varian linac focal spot alignment

Slama et al., 2019

Document ID
6934135969812030588
Author
Slama L
Riis H
Sabet M
Barnes M
Ebert M
Chan S
Rowshanfarzad P
Publication year
Publication venue
Physica Medica

External Links

Snippet

The characteristics of the focal spot of the linear accelerator (linac) play a role in determining the resulting dose distribution within the patient, and hence probability of treatment success. A direct measurement of focal spot position is not recommended by AAPM Task Group 142 …
Continue reading at www.sciencedirect.com (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1064Monitoring, verifying, controlling systems and methods for adjusting radiation treatment in response to monitoring
    • A61N5/1065Beam adjustment
    • A61N5/1067Beam adjustment in real time, i.e. during treatment
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1075Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
    • A61N2005/1076Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1049Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
    • A61N2005/1061Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam using an x-ray imaging system having a separate imaging source
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1049Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
    • A61N2005/1056Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam by projecting a visible image of the treatment field
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N2005/1085X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy characterised by the type of particles applied to the patient
    • A61N2005/1087Ions; Protons
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1077Beam delivery systems
    • A61N5/1081Rotating beam systems with a specific mechanical construction, e.g. gantries
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/103Treatment planning systems
    • A61N5/1037Treatment planning systems taking into account the movement of the target, e.g. 4D-image based planning
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1042X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy with spatial modulation of the radiation beam within the treatment head
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N2005/1092Details
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/01Devices for producing movement of radiation source during therapy
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/54Control of devices for radiation diagnosis

Similar Documents

Publication Publication Date Title
US12233285B2 (en) Systems, methods, and devices for radiation beam asymmetry measurements using electronic portal imaging devices
US12194315B2 (en) Systems, methods, and devices for radiation beam alignment and radiation beam measurements using electronic portal imaging devices
US20230241417A1 (en) Radiation based treatment beam position calibration and verification
Chang et al. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines
Clivio et al. Evaluation of the machine performance check application for TrueBeam Linac
GB2520674A (en) Radiotherapy beam alignment
Slama et al. Beam focal spot intrafraction motion and gantry angle dependence: a study of Varian linac focal spot alignment
Woods et al. Technical Report: TG‐142 compliant and comprehensive quality assurance tests for respiratory gating
Nyflot et al. Improved accuracy for noncoplanar radiotherapy: an EPID‐based method for submillimeter alignment of linear accelerator table rotation with MV isocenter
KR101872226B1 (en) Calibration unit, apparatus for radiotherapy and calibration method thereof
Chojnowski et al. A novel method to determine linac mechanical isocenter position and size and examples of specific QA applications
Hardcastle et al. Results of patient specific quality assurance for patients undergoing stereotactic ablative radiotherapy for lung lesions
Mastella et al. Validation of a pretreatment delivery quality assurance method for the CyberKnife Synchrony system
Wegener et al. Implementing corrections of isocentric shifts for the stereotactic irradiation of cerebral targets: Clinical validation
Pantelis et al. Use of radiochromic films in commissioning and quality assurance of CyberKnife®
Zhang et al. Validation of a 2D dose verification systemfor intensity-modulated arc therapy
Kemikler et al. Beam characteristics of megavoltage beams at low monitor unit settings
Park et al. Mechanical quality assurance using light field for linear accelerators with camera calibration
Pantelis et al. Quality Control
Liang et al. Small field commissioning and verification for the uRT-TPOIS radiotherapy treatment planning system
Fontenla IMRT treatment plans: dosimetry measurements and monitor units validation
Rhein et al. 3D Quality Assurance Systems
Mhatre et al. EP-1532: Reliability of the Machine Performance Check application for TrueBeam STx Linac
Baker et al. Investigation of Beam Central Axis Position Offsets Using an Automatic Analysis Tool with an EPID Panel
Malka Electrons and protons beams produced by compact lasers: a new tool for medicine