Khabaz et al., 2020 - Google Patents

Assessment of Kerma coefficients for OSL dosimeters by analytical and Monte Carlo approaches

Khabaz et al., 2020

Document ID
5843054621504791434
Author
Khabaz R
Vega-Carrillo H
Publication year
Publication venue
Radiation Physics and Chemistry

External Links

Snippet

In optically stimulated luminescent dosimeters (OSLD), the intensity of luminescent is a function of the dose of radiation absorbed and then it may be utilized as the basis of a radiation dosimetry method. For photons in the energy range from 1 keV to 20 MeV, the …
Continue reading at www.sciencedirect.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/169Exploration, location of contaminated surface areas in situ measurement, e.g. floor contamination monitor
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/167Measuring radioactive content of objects, e.g. contamination
    • GPHYSICS
    • G21NUCLEAR PHYSICS; NUCLEAR ENGINEERING
    • G21FPROTECTION AGAINST X-RADIATION, GAMMA RADIATION, CORPUSCULAR RADIATION OR PARTICLE BOMBARDMENT; TREATING RADIOACTIVELY CONTAMINATED MATERIAL; DECONTAMINATION ARRANGEMENTS THEREFOR
    • G21F1/00Shielding characterised by the composition of the materials
    • G21F1/02Selection of uniform shielding materials
    • G21F1/06Ceramics; Glasses; Refractories
    • GPHYSICS
    • G21NUCLEAR PHYSICS; NUCLEAR ENGINEERING
    • G21FPROTECTION AGAINST X-RADIATION, GAMMA RADIATION, CORPUSCULAR RADIATION OR PARTICLE BOMBARDMENT; TREATING RADIOACTIVELY CONTAMINATED MATERIAL; DECONTAMINATION ARRANGEMENTS THEREFOR
    • G21F1/00Shielding characterised by the composition of the materials
    • G21F1/02Selection of uniform shielding materials
    • G21F1/10Organic substances; Dispersions in organic carriers
    • GPHYSICS
    • G21NUCLEAR PHYSICS; NUCLEAR ENGINEERING
    • G21KTECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
    • G21K1/00Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating

Similar Documents

Publication Publication Date Title
Olko Advantages and disadvantages of luminescence dosimetry
Hill et al. Advances in kilovoltage x-ray beam dosimetry
McAlister Gamma ray attenuation properties of common shielding materials
Williamson et al. Plastic scintillator response to low-energy photons
Scarboro et al. Characterisation of energy response of Al2O3: C optically stimulated luminescent dosemeters (OSLDs) using cavity theory
Khabaz et al. Assessment of Kerma coefficients for OSL dosimeters by analytical and Monte Carlo approaches
Hopkins et al. Linear attenuation coefficient and buildup factor of MCP-96 alloy for dose accuracy, beam collimation, and radiation protection
Domenech Shielding
Takegami et al. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment
Wakabayashi et al. Applicability of self-activation of an NaI scintillator for measurement of photo-neutrons around a high-energy X-ray radiotherapy machine
Van Hoey et al. Evaluation of different types of lithium fluoride thermoluminescent detectors for ring dosimetry in nuclear medicine
Marashdeh et al. Dosimetric evaluation of Rhizophora spp. binderless particleboard phantom for diagnostic X-ray energy
Tochitani et al. Response control of RPLGD for gamma-ray dose measurement using lead filters for BNCT
Khabaz Assessment of flux and energy buildup factors in shielding of some gamma sources used for industrial radiography
Kulkarni et al. Studies on new neutron-sensitive dosimeters using an optically stimulated luminescence technique
Amgarou et al. Monte Carlo simulation of the NaI (Tl) detector response to measure gold activated foils
Kumar et al. An experimental study of the relative response of plastic scintillators to photons and beta particles
Coudin et al. Lithium borate TLD for determining the backscatter factors for low‐energy x rays: Comparison with chamber‐based and Monte Carlo derived values
Zhou et al. Angular distribution of neutron production by proton and carbon-ion therapeutic beams
Le et al. Evaluation of gamma contribution in a neutron calibration field of Am− Be241 source
Lin et al. Evaluation of stray neutron distribution in medical cyclotron vault room by neutron activation analysis approach
Chopra et al. Principle, mechanism, and models of radiation dosimetry
Cruz et al. Energy and angular dependence of the small-type OSL dosimeter in nuclear medicine regions using Monte Carlo simulation
VinayKumar et al. Coherent scattering cross sections of some lanthanides for 241Am and 137Cs gamma rays at low momentum transfer
Tajudin et al. Doped Plastic Scintillator Properties for Soft Tissue Dosimetry