Fouad et al., 1989 - Google Patents
An in vitro comparison of five root canal length measuring instrumentsFouad et al., 1989
- Document ID
- 566534615192616250
- Author
- Fouad A
- Krell K
- Publication year
- Publication venue
- Journal of endodontics
External Links
Snippet
Several new root canal length measuring instruments (RCLMI) have recently been introduced claiming superiority over older systems. The purpose of this study was to compare five models of these instruments with respect to their accuracy under a given set of …
- 210000004262 Dental Pulp Cavity 0 title abstract description 8
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/45—For evaluating or diagnosing the musculoskeletal system or teeth
- A61B5/4538—Evaluating a particular part of the muscoloskeletal system or a particular medical condition
- A61B5/4542—Evaluating the mouth, e.g. the jaw
- A61B5/4547—Evaluating teeth
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C19/00—Dental auxiliary appliances
- A61C19/04—Measuring instruments specially adapted for dentistry
- A61C19/05—Measuring instruments specially adapted for dentistry for determining occlusion
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/053—Measuring electrical impedance or conductance of a portion of the body
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01N—INVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
- G01N33/00—Investigating or analysing materials by specific methods not covered by the preceding groups
- G01N33/48—Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
- G01N33/483—Physical analysis of biological material
- G01N33/487—Physical analysis of biological material of liquid biological material
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61C—DENTISTRY; APPARATUS OR METHODS FOR ORAL OR DENTAL HYGIENE
- A61C5/00—Filling or capping teeth
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Fouad et al. | An in vitro comparison of five root canal length measuring instruments | |
Fouad et al. | A clinical evaluation of five electronic root canal length measuring instruments | |
Haffner et al. | Accuracy of electronic apex locators in comparison to actual length—an in vivo study | |
Allison et al. | The influence of master cone adaptation on the quality of the apical seal | |
Ibarrola et al. | Effect of preflaring on Root ZX apex locators | |
Ebrahim et al. | The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex locator in enlarged root canals: an in vitro study | |
McDonald et al. | An evaluation of the apex locator Endocater | |
Tinaz et al. | A simple model to demonstrate the electronic apex locator. | |
EP2496173B1 (en) | Device for the detection of non-cavitated early dental caries lesions | |
Meredith et al. | Electrical impedance measurements of root canal length | |
AU2012246764B2 (en) | A Device and Method for Detecting a Harmonic Response Characteristic of Secondary Dental Caries Diagnosis | |
US6520775B2 (en) | Fixture and method for training and use of apical position locator | |
Nekoofar et al. | The accuracy of the Neosono Ultima EZ apex locator using files of different alloys: an in vitro study | |
Suchde et al. | Electronic ohmmeter: an electronic device for the determination of the root canal length | |
Kuştarci et al. | In vitro comparison of working length determination using three different electronic apex locators | |
US4102047A (en) | Dental teaching device | |
Kovačević et al. | Influence of the concentration of ions and foramen diameter on the accuracy of electronic root canal length measurement—An experimental study | |
Nahmias et al. | Expanded use of the electronic canal length measuring devices | |
Felippe et al. | In vitro evaluation of an audiometric device in locating the apical foramen of teeth | |
Kaufman et al. | The efficiency and reliability of the Dentometer for detecting root canal length | |
Scholander et al. | Simple calibrator for Warburg respirometers | |
Ushiyama et al. | A clinical evaluation of the voltage gradient method of measuring the root canal length | |
Karthik | Pradeep. S, Dhanraj Ganapathy. A Comparative Evaluation Of Efficacy Of Apex Locators Vs Radiovisiograph In Determining The Working Length Of Single Rooted Teeth-An In-Vitro Study | |
Joshua Moshonov et al. | In vivo evaluation of Apex NRG, a new apex locator, and its comparison with Root ZX | |
SU904659A1 (en) | Odontodiagnosis method |