Ebert et al., 2001 - Google Patents
3D image guidance in radiotherapy: a feasibility studyEbert et al., 2001
- Document ID
- 5475226015010987707
- Author
- Ebert M
- Groh B
- Partridge M
- Hesse B
- Bortfeld T
- Publication year
- Publication venue
- Medical Imaging 2001: Image Processing
External Links
Snippet
Currently, one major research field in radiotheraphy is focused on patient setup verification and on detection of organ motion and deformation. A phantom study is performed to demonstrate the feasibility of image guidance in radiotherapy. Patient setup errors are …
- 238000001959 radiotherapy 0 title abstract description 29
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
- A61N2005/1061—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam using an x-ray imaging system having a separate imaging source
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1064—Monitoring, verifying, controlling systems and methods for adjusting radiation treatment in response to monitoring
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
- A61B6/583—Calibration using calibration phantoms
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/44—Constructional features of the device for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/42—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
- A61B6/4291—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis the detector being combined with a grid or grating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/006—Inverse problem, transformation from projection-space into object-space, e.g. transform methods, back-projection, algebraic methods
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Ford et al. | Cone‐beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: Potential for verification of radiotherapy of lung cancer | |
Jaffray et al. | Flat-panel cone-beam computed tomography for image-guided radiation therapy | |
Sykes et al. | A feasibility study for image guided radiotherapy using low dose, high speed, cone beam X-ray volumetric imaging | |
Jaffray et al. | A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets | |
Murphy et al. | The management of imaging dose during image‐guided radiotherapy: report of the AAPM Task Group 75 | |
US7453976B1 (en) | Computerized tomography image reconstruction | |
US7532705B2 (en) | Systems and methods for localizing a target for radiotherapy based on digital tomosynthesis | |
Lu et al. | Four‐dimensional cone beam CT with adaptive gantry rotation and adaptive data sampling | |
US6842502B2 (en) | Cone beam computed tomography with a flat panel imager | |
Yin et al. | A technique for on‐board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification | |
Jaffray et al. | Performance of a volumetric CT scanner based upon a flat-panel imager | |
Brunner et al. | Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy | |
Vinogradskiy et al. | Verification of four‐dimensional photon dose calculations | |
Ali et al. | Evaluation of the effects of sagging shifts on isocenter accuracy and image quality of cone‐beam CT from kV on‐board imagers | |
Harris et al. | Impact of a novel multilayer imager on metal artifacts in MV-CBCT | |
Chang et al. | Panoramic cone beam computed tomography | |
Ebert et al. | 3D image guidance in radiotherapy: a feasibility study | |
Speidel et al. | Feasibility of low‐dose single‐view 3D fiducial tracking concurrent with external beam delivery | |
Mueller et al. | Cone-beam computed tomography (CT) for a megavoltage linear accelerator (LINAC) using an electronic portal imaging device (EPID) and the algebraic reconstruction technique (ART) | |
Schreiner et al. | Metal artifact suppression in megavoltage computed tomography | |
Ploquin et al. | Phantom evaluation of a commercially available three modality image guided radiation therapy system | |
Zhang et al. | Minimizing image noise in on‐board CT reconstruction using both kilovoltage and megavoltage beam projections | |
Zhu et al. | A patient set-up protocol based on partially blocked cone-beam CT | |
Lee et al. | Preliminary study of integrated C-arm CT/SPECT imaging system for online adaptive 3D brachytherapy using Monte Carlo simulation | |
Harris | A Novel Megavoltage Multilayer Imager Improves Clinical Beam’s-Eye-View Performance |