[go: up one dir, main page]

Haugh et al., 2008 - Google Patents

Flat field anomalies in an x-ray CCD camera measured using a Manson x-ray source

Haugh et al., 2008

View PDF
Document ID
4316416416655219242
Author
Haugh M
Schneider M
et al.
Publication year
Publication venue
Conference High Temperature Plasma Diagnostics

External Links

Snippet

The Static X-ray Imager (SXI) is a diagnostic used at the National Ignition Facility (NIF) to measure the position of the X-rays produced by lasers hitting a gold foil target. The intensity distribution taken by the SXI camera during a NIF shot is used to determine how accurately …
Continue reading at www.academia.edu (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/20Measuring radiation intensity with scintillation detectors
    • G01T1/2018Scintillation-photodiode combination
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J1/00Photometry, e.g. photographic exposure meter
    • G01J1/02Details
    • G01J1/04Optical or mechnical part supplementary adjustable parts
    • G01J1/0407Optical elements not provided otherwise, e.g. manifolds, windows, holograms, gratings
    • G01J1/0414Optical elements not provided otherwise, e.g. manifolds, windows, holograms, gratings using plane or convex mirrors, parallel phase plates, or plane beam-splitters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J1/00Photometry, e.g. photographic exposure meter
    • G01J1/42Photometry, e.g. photographic exposure meter using electric radiation detectors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01JMEASUREMENT OF INTENSITY, VELOCITY, SPECTRAL CONTENT, POLARISATION, PHASE OR PULSE CHARACTERISTICS OF INFRA-RED, VISIBLE OR ULTRA-VIOLET LIGHT; COLORIMETRY; RADIATION PYROMETRY
    • G01J5/00Radiation pyrometry
    • G01J2005/0048Calibrating; Correcting
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T7/00Details of radiation-measuring instruments

Similar Documents

Publication Publication Date Title
US11013479B2 (en) Semiconductor X-ray detector
US11063082B2 (en) Methods of making semiconductor X-ray detector
Donath et al. Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV
Haugh et al. Calibrating image plate sensitivity in the 700 to 5000 eV spectral energy range
US20170045632A1 (en) Method to calibrate a photon detector, absorption filter assembly and imaging apparatus
Veale et al. Cadmium zinc telluride pixel detectors for high-intensity x-ray imaging at free electron lasers
Vespucci et al. Robust energy calibration technique for photon counting spectral detectors
Haugh et al. Calibration of X-ray imaging devices for accurate intensity measurement
Staeck et al. Towards soft x-ray fluorescence measurements in the laboratory using a laser-produced plasma source and a complementary metal-oxide semiconductor detector
US20210405223A1 (en) Semiconductor X-Ray Detector
Ling et al. A correlogram method to examine the crosstalk of sCMOS sensors
Haugh et al. Flat field anomalies in an x-ray CCD camera measured using a Manson x-ray source
Tsigaridas et al. Characterisation of pixelated CdZnTe sensors using MAXIPIX
Haugh et al. Flat Field Anomalies in an X-ray CCD Camera Measured Using a Manson X-ray Source (HTPD 08 paper)
Haugh et al. Flat field anomalies in an x-ray charge coupled device camera measured using a Manson x-ray source
Liu et al. Research on a back-illuminated CMOS sensor for LUV imaging
Koch et al. Detective quantum efficiency of an x-ray image intensifier chain as a benchmark for amorphous silicon flat-panal detectors
Arora et al. Dispersion-less spectrograph for absolute measurement of multi keV X-ray flux from high intensity laser produced plasmas
Prest et al. Improved QE in CMOS image sensors with nano-black antireflection layer
Matheson et al. Testing and comparison of imaging detectors for electrons in the energy range 10–20 keV
Mikulec et al. A high resolution, high frame rate detector based on a microchannel plate readout with the Medipix2 counting CMOS pixel chip
Banyay et al. Line image sensors for spectroscopic applications in the extreme ultraviolet
Schioppa et al. Measurement of the energy response function of a silicon pixel detector readout by a Timepix chip using synchrotron radiation
Song et al. Easy way to evaluate CCDs for astronomical use
Haugh et al. Quantitative measurements of x-ray intensity