David et al., 2010 - Google Patents
Evaluation of the luminescence efficiency of YAG: Ce powder scintillating screens for use in digital mammography detectorsDavid et al., 2010
- Document ID
- 407726522257334127
- Author
- David S
- Michail C
- Roussou M
- Nirgianaki E
- Toutountzis A
- Valais I
- Fountos G
- Liaparinos P
- Kandarakis I
- Panayiotakis G
- Publication year
- Publication venue
- IEEE Transactions on Nuclear Science
External Links
Snippet
In the present study scintillating screens prepared from Y 3 Al 5 O 12: Ce (YAG: Ce) powder phosphor were evaluated for use in digital mammography. YAG: Ce has never previously been used in X-ray medical imaging, however since it emits green light (ie peak at 550 nm) …
- 238000009607 mammography 0 title abstract description 23
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2018—Scintillation-photodiode combination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2006—Measuring radiation intensity with scintillation detectors using a combination of a scintillator and photodetector which measures the means radiation intensity
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/202—Measuring radiation intensity with scintillation detectors the detector being a crystal
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
Similar Documents
Publication | Publication Date | Title |
---|---|---|
JP5450920B2 (en) | Image forming assembly and inspection method thereof | |
Seferis et al. | Light emission efficiency and imaging performance of Lu2O3: Eu nanophosphor under X-ray radiography conditions: Comparison with Gd2O2S: Eu | |
Valais et al. | Luminescence efficiency of Gd/sub 2/SiO/sub 5: Ce scintillator under X-ray excitation | |
Kalyvas et al. | Studying the luminescence efficiency of Lu2O3: Eu nanophosphor material for digital X-ray imaging applications | |
David et al. | Evaluation of Gd2O2S: Pr granular phosphor properties for X-ray mammography imaging | |
Kandarakis et al. | X-ray luminescence of ZnSCdS: Au, Cu phosphor using X-ray beams for medical applications | |
Michail et al. | A comparative investigation of Lu2SiO5: Ce and Gd2O2S: Eu powder scintillators for use in x-ray mammography detectors | |
Valais et al. | Luminescence Properties of $({\rm Lu},{\rm Y}) _ {2}{\rm SiO} _ {5}:{\rm Ce} $ and ${\rm Gd} _ {2}{\rm SiO} _ {5}:{\rm Ce} $ Single Crystal Scintillators Under X-Ray Excitation for Use in Medical Imaging Systems | |
Liu et al. | flat‐panel versus computed radiography for chest imaging applications: image quality metrics measurement | |
Kandarakis et al. | On the response of Y3Al5O12: Ce (YAG: Ce) powder scintillating screens to medical imaging X-rays | |
Kandarakis et al. | Experimental and theoretical assessment of the performance of Gd2O2S: Tb and La2O2S: Tb phosphors and Gd2O2S: Tb–La2O2S: Tb mixtures for X-ray imaging | |
Kandarakis et al. | Evaluation of ZnS: Cu phosphor as X-ray to light converter under mammographic conditions | |
Cavouras et al. | An experimental method to determine the effective luminescence efficiency of scintillator-photodetector combinations used in X-ray medical imaging systems. | |
Michail et al. | Light Emission Efficiency of ${\rm Gd} _ {2}{\rm O} _ {2}{\rm S}\!\!\!:\!\!\!{\rm Eu} $(GOS: Eu) Powder Screens Under X-Ray Mammography Conditions | |
Farman et al. | Effects of scintillator on the detective quantum efficiency (DQE) of a digital imaging system | |
Kandarakis et al. | Role of the activator in the performance of scintillators used in X-ray imaging | |
Cavouras et al. | Light emission efficiency and imaging performance of Y3Al5O12: Ce (YAG: Ce) powder screens under diagnostic radiology conditions | |
Michail et al. | Imaging performance and light emission efficiency of Lu2 SiO5: Ce (LSO: Ce) powder scintillator under X-ray mammographic conditions | |
Martini et al. | Imaging performance of a CaWO4/CMOS sensor | |
David et al. | Evaluation of the luminescence efficiency of YAG: Ce powder scintillating screens for use in digital mammography detectors | |
Cavouras et al. | Measurement of the (Gd, La) 2O2S: Tb phosphor efficiency for x-ray imaging applications | |
Cavouras et al. | Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors | |
Kandarakis et al. | Measurement of the X-ray luminescence and spectral compatibility of the CdPO3CI: Mn phosphor | |
David et al. | Investigation of Luminescence Properties of Lu $ _ {2} $ SiO $ _ {5} $: Ce (LSO) Powder Scintillator in the X-Ray Radiography Energy Range | |
Δαυίδ et al. | Luminescence efficiency of fast yttrium aluminum garnet phosphor screens for use in digital breast tomosynthesis |