Minniti et al., 2011 - Google Patents
Comparison of the air kerma standards for 137Cs and 60Co gamma-ray beams between the IAEA and the NISTMinniti et al., 2011
View PDF- Document ID
- 3154493480502137223
- Author
- Minniti R
- Czap L
- Publication year
- Publication venue
- Metrologia
External Links
Snippet
A comparison of the air kerma standards for 137 Cs and 60 Co gamma ray beams was performed between the NIST and the IAEA. Two reference class ionization chambers owned by the IAEA were used as part of this comparison and were calibrated at each facility. The …
- 230000005251 gamma ray 0 title abstract description 17
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/10—Luminescent dosimeters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/169—Exploration, location of contaminated surface areas in situ measurement, e.g. floor contamination monitor
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/185—Measuring radiation intensity with ionisation chamber arrangements
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1075—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
- A61N2005/1076—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Bassinet et al. | Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones | |
Shortt et al. | A comparison of absorbed dose standards for high-energy x-rays | |
Büermann et al. | Air-kerma cavity standards | |
CN107992699A (en) | A kind of emulation detection method of dose of radiation suffered by eye lens | |
Medin | Implementation of water calorimetry in a 180 MeV scanned pulsed proton beam including an experimental determination of kQ for a Farmer chamber | |
Minniti et al. | Comparison of the air kerma standards for 137Cs and 60Co gamma-ray beams between the IAEA and the NIST | |
Allisy-Roberts et al. | Comparison of the standards for air kerma of the NMIJ and the BIPM for 60Co γ rays | |
Picard et al. | Key comparison BIPM. RI (I)-K6 of the standards for absorbed dose to water of the LNE–LNHB, france and the BIPM in accelerator photon beams | |
Leitner et al. | International comparisons of air kerma standards in 137Cs gamma radiation | |
Neves et al. | Development and Characterization of a New Cylindrical Ionization Chamber for Dosimetry of $^{60}{\rm Co} $ Beams | |
Kessler et al. | Key comparison BIPM. RI (I)-K1 of the air-kerma standards of the BEV, Austria and the BIPM in 60 Co gamma radiation | |
Kessler et al. | Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays | |
Moon et al. | Reference dosimetry and calibration of glass dosimeters for Cs-137 gamma-rays | |
Minniti et al. | Calibration of a 137Cs γ-ray beam irradiator using large size chambers | |
Kessler et al. | Key comparison BIPM. RI (I)-K4 of the absorbed dose to water standards of the BEV, Austria and the BIPM in 60Co gamma radiation | |
Stancu et al. | Absorbed dose to water measurements in high energy electron beams using different plane parallel chambers | |
Kessler et al. | Comparisons of the radiation protection standards for air kerma of the NIST and the BIPM for 60Co and 137Cs gamma radiation | |
Kessler et al. | Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60 Co gamma radiation | |
Picard et al. | Key comparison BIPM. RI (I)-K6 of the standards for absorbed dose to water at 10 g cm–2 of the NIM, China and the BIPM in accelerator photon beams | |
Kessler et al. | Key comparison BIPM. RI (I)-K5 of the air kerma standards of the NIM, China, and the BIPM in 137Cs gamma radiation | |
Burns et al. | Key comparison BIPM. RI (I)-K3 of the air-kerma standards of the ARPANSA, Australia, and the BIPM in medium-energy x-rays | |
Allisy-Roberts et al. | Comparison of the standards of air kerma of the LNE-LNHB and the BIPM for {sup 60} Co gamma radiation | |
Kessler et al. | Comparison BIPM. RI (I)-K6 of the standards for absorbed dose to water of the LNE-LNHB, France and the BIPM in accelerator photon beams | |
Stark et al. | The determination of fluence to dose equivalent conversion factors for Americium-Beryllium and Californium Sources from microdosimetric measurements | |
Scarlat et al. | On the absorbed dose determination method in high energy photon beams |