Koeppl et al., 2010 - Google Patents

New aspects for neutral grounding of generators considering intermittent faults

Koeppl et al., 2010

View PDF
Document ID
17470614939865279869
Author
Koeppl G
Braun D
Publication year
Publication venue
proceedings of the Congreso Internacional de Distribución Eléctrica, Buenos Aires, Argentina

External Links

Snippet

1-phase faults in generator stator windings are predominantly intermittent arcing faults, as may be deduced from MV cable tests. Simulations show that energy absorption in the fault resistance at intermittent faults is about 20 times higher than for a persistent" textbook" fault …
Continue reading at www.researchgate.net (PDF) (other versions)

Classifications

    • HELECTRICITY
    • H01BASIC ELECTRIC ELEMENTS
    • H01HELECTRIC SWITCHES; RELAYS; SELECTORS; EMERGENCY PROTECTIVE DEVICES
    • H01H33/00High-tension or heavy-current switches with arc-extinguishing or arc-preventing means
    • H01H33/02Details
    • H01H33/04Means for extinguishing or preventing arc between current-carrying parts
    • H01H33/12Auxiliary contacts on to which the arc is transferred from the main contacts
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H1/00Details of emergency protective circuit arrangements
    • H02H1/0007Details of emergency protective circuit arrangements concerning the detecting means
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H3/00Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection
    • H02H3/26Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents
    • H02H3/32Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors
    • H02H3/33Emergency protective circuit arrangements for automatic disconnection directly responsive to an undesired change from normal electric working condition with or without subsequent reconnection integrated protection responsive to difference between voltages or between currents; responsive to phase angle between voltages or between currents involving comparison of the voltage or current values at corresponding points in different conductors of a single system, e.g. of currents in go and return conductors using summation current transformers
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H9/00Emergency protective circuit arrangements for limiting excess current or voltage without disconnection
    • H02H9/04Emergency protective circuit arrangements for limiting excess current or voltage without disconnection responsive to excess voltage
    • HELECTRICITY
    • H02GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER
    • H02HEMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS
    • H02H7/00Emergency protective circuit arrangements specially adapted for specific types of electric machines or apparatus or for sectionalised protection of cable or line systems, and effecting automatic switching in the event of an undesired change from normal working conditions
    • H02H7/26Sectionalised protection of cable or line systems, e.g. for disconnecting a section on which a short-circuit, earth fault, or arc discharge has occured

Similar Documents

Publication Publication Date Title
Glinkowski et al. Voltage escalation and reignition behavior of vacuum generator circuit breakers during load shedding
Bak et al. Vacuum circuit breaker modelling for the assessment of transient recovery voltages: Application to various network configurations
US20030214302A1 (en) Synthetic making/breaking-capacity test circuit for high-voltage alternating-current circuit-breakers
Yang et al. Field experiments on overvoltage caused by 12-kV vacuum circuit breakers switching shunt reactors
Borghetti et al. Transient recovery voltages in vacuum circuit breakers generated by the interruption of inrush currents of large motors
Szewczyk et al. Impact of disconnector design on very fast transient overvoltages in gas-insulated UHV switchgear
Liljestrand et al. Vacuum circuit breaker and transformer interaction in a cable system
Koeppl et al. New aspects for neutral grounding of generators considering intermittent faults
Palazzo et al. New requirements for the application of generator circuit-breakers
Braun et al. Intermittent line-to-ground faults in generator stator windings and consequences on neutral grounding
Perkins et al. Vacuum switchgear application study with reference to switching surge protection
Rashkes et al. Very high frequency overvoltages at open air EHV substations during disconnect switch operations
Marukatat et al. Design and Construction of a Combination Wave Generator
Kumar et al. High Voltage Motor Current Switching tests: It’s Motive & Evaluation
Ueno et al. Monte-Carlo simulation of overvoltage generation in the inductive current interruption by vacuum interrupters
Parvizi et al. Sensitivity analysis of TRV in TCSC compensated transmission lines during fault clearing by line CB
Lee et al. Study on transient recovery voltage for testing of high-voltage circuit breakers
Challagondla et al. The study of very fast transient over voltages (VFTO) for the project of 400/220kV GIS substation with one and half circuit breaker configuration
Taylor et al. Single-phase short-circuit testing of vacuum interrupters for power systems with an effectively earthed neutral
Vollet et al. Vacuum circuit breaker model: application case to motors switching
Sabath et al. Analog Computer Study of Switching Surge Transients for a 500-ky System
Kauhaniemi et al. Switching overvoltages of shunt reactors when opening the circuit breaker
JP2666946B2 (en) Capacitor switching performance test equipment
Das Effects of medium voltage capacitor bank switching surges in an industrial distribution system
Meera et al. Switching and Power Frequency transients in EHV systems A review and Case Study