An automated system for the measurement of alanine/EPR dosimeters

Sharpe et al., 2000

View PDF
Document ID
17143035436481099156
Author
Sharpe P
Sephton J
Publication year
Publication venue
Applied Radiation and Isotopes

External Links

Snippet

NPL for several years has offered mailed reference dosimetry services based on alanine/EPR dosimeters, both at industrial and therapy dose levels. Compared to other methods of reference dosimetry, operator involvement in alanine/EPR has been found to be …
Continue reading at eprintspublications.npl.co.uk (PDF) (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/17Circuit arrangements not adapted to a particular type of detector
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N30/00Investigating or analysing materials by separation into components using adsorption, absorption or similar phenomena or using ion-exchange, e.g. chromatography or field flow fractionation
    • G01N30/02Column chromatography
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N1/00Sampling; Preparing specimens for investigation
    • G01N1/28Preparing specimens for investigation including physical details of (bio-)chemical methods covered elsewhere, e.g. G01N33/50, C12Q
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T7/00Details of radiation-measuring instruments
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N23/00Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons
    • G01N23/20Investigating or analysing materials by the use of wave or particle radiation not covered by G01N21/00 or G01N22/00, e.g. X-rays or neutrons by using diffraction of the radiation, e.g. for investigating crystal structure; by using reflection of the radiation
    • G01N23/20008Constructional details; Accessories
    • G01N23/20025Sample holders or supports

Similar Documents

Publication Publication Date Title
Bradshaw et al. The use of alanine as a solid dosimeter
Sharpe et al. An automated system for the measurement of alanine/EPR dosimeters
FOLKARD, B. VOJNOVIC, KM PRISE, AG BOWEY, RJ LOCKE, G. SCHETTINO and BD MICHAEL A charged-particle microbeam: I. Development of an experimental system for targeting cells individually with counted particles
Anton Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt
Sibbens et al. Preparation of radioactive sources for radionuclide metrology
CN108535761A (en) A kind of rotary α, β surface contamination analyzer calibration and calibrating installation
CN107884803B (en) Heat-releasing light irradiator
Becker Environmental monitoring with TLD
Ward et al. Study of Some of the Parameters Affecting Knudsen Effusion. I. Experimental Tests of the Validity of the Cosine Law as a Function of Cell and Sample Geometrics and Materials
Gerardi et al. A microcollimated ion beam facility for investigations of the effects of low-dose radiation
CN213182049U (en) Gamma spectrometer shielding chamber structure
Massoni et al. A pneumatic sample changer for gamma-ray spectroscopy
Chen et al. Preparation of thin alpha sources by electrospraying for efficiency calibration purposes
Ravindra et al. Development of plastic scintillator based primary standard for activity measurements and its performance evaluation
Joseph et al. An automated LS (β)-NaI (Tl)(γ) coincidence system as absolute standard for radioactivity measurements
Lee et al. International Proficiency Test for Radioactivity by Gamma Spectroscopy Evaluation of Results
Zhao et al. Characteristic and performance of a simple thoron chamber
Mackey et al. Use of neutron beams for chemical analysis at NIST
Van Ammel et al. Qualification of a precision pattern dispenser
Jansholt et al. Design and validation of a radiochromatogram scanner with analog and digital output
Shortt et al. The Response of LiF TLDs to 137Cs and 60Co gamma-Rays
Cantone et al. Chromium in human serum determined by proton activation
CN107297024A (en) A kind of betaapplicator surface absorber dose rate calibrating installation and method
Hoede et al. Accuracy and precision of instrumental neutron activation analysis based on gamma-spectrometry with a planar intrinsic Ge detector
Gunn et al. High Precision Irradiation Techniques for NTD Silicon at the University of Missouri Research Reactor