Numerical and experimental study of air containment systems in legacy data centers focusing on thermal performance and air leakageCho et al., 2021
View HTML- Document ID
- 16939732417678641085
- Author
- Cho J
- Park C
- Choi W
- Publication year
- Publication venue
- Case Studies in Thermal Engineering
External Links
Snippet
With the increasing awareness of data center cooling and its impact on energy costs, hot- aisle containment (HAC) and cold-aisle containment (CAC) are considered vital techniques for IT environment control. Common data center cooling problems, which include air bypass …
- 238000001816 cooling 0 abstract description 82
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F17/00—Digital computing or data processing equipment or methods, specially adapted for specific functions
- G06F17/50—Computer-aided design
- G06F17/5009—Computer-aided design using simulation
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/80—Thermal analysis and optimization
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F2217/00—Indexing scheme relating to computer aided design [CAD]
- G06F2217/78—Power analysis and optimization
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Cho et al. | Numerical and experimental study of air containment systems in legacy data centers focusing on thermal performance and air leakage | |
| Nada et al. | Numerical investigation and parametric study for thermal and energy management enhancements in data centers' buildings | |
| US8639482B2 (en) | Methods and systems for managing facility power and cooling | |
| US7881910B2 (en) | Methods and systems for managing facility power and cooling | |
| EP1877950B1 (en) | Methods and systems for managing facility power and cooling | |
| Tradat et al. | An experimental and numerical investigation of novel solution for energy management enhancement in data centers using underfloor plenum porous obstructions | |
| Nada et al. | Experimental investigations of thermal managements solutions in data centers buildings for different arrangements of cold aisles containments | |
| Fulpagare et al. | Experimental analysis of airflow uniformity and energy consumption in data centers | |
| US20190008072A1 (en) | Methods and systems for managing facility power and cooling | |
| Nada et al. | Experimental study of solving thermal heterogeneity problem of data center servers | |
| Jin et al. | The study of servers’ arrangement and air distribution strategy under partial load in data centers | |
| Alissa et al. | Innovative approaches of experimentally guided CFD modeling for data centers | |
| Chu et al. | Experimental investigation on thermal management for small container data center | |
| Song | Studying the fan-assisted cooling using the Taguchi approach in open and closed data centers | |
| Sheth et al. | Numerical study of thermal management of data centre using porous medium approach | |
| Gao et al. | Comparative analysis of different in row cooler management configurations in a hybrid cooling data center | |
| Nemati et al. | Steady-state and transient comparison of cold and hot aisle containment and chimney | |
| US20130275097A1 (en) | Air flow estimation | |
| Song | Numerical investigation for performance indices and categorical designs of a fan-assisted data center cooling system | |
| Saiyad et al. | Comparison of detached eddy simulation and standard k—ε RANS model for rack-level airflow analysis inside a data center | |
| Zhang et al. | Optimization on jet‐induced ventilation to enhance the uniformity of airflow distribution in data center | |
| Singh et al. | Retrofitting HVAC systems for enhanced energy performance and resilience in university data center room | |
| Song et al. | Numerical investigation of inter-zonal boundary conditions for data center thermal analysis | |
| Peng et al. | Research on cooling performance of a built-in cooling equipment for server rack | |
| Feng et al. | Investigating thermal performance and energy efficiency in under-floor air distribution data centers: A case study |