Feasibility of isodose‐shaped scintillation detectors for the measurement of gamma knife output factors

Kim et al., 2022

Document ID
16377773534886626168
Author
Kim T
Yang H
Jeong J
Schaarschmidt T
Kim Y
Chung H
Publication year
Publication venue
Medical Physics

External Links

Snippet

Purpose Scintillation detectors were 3D printed based on a gamma knife (GK) dose distribution to calculate the volume averaging effect. The collimator output factors were measured using isodose‐shaped scintillators (ISSs) and compared with those of a micro …
Continue reading at aapm.onlinelibrary.wiley.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • G01T1/1648Ancillary equipment for scintillation cameras, e.g. reference markers, devices for removing motion artifacts, calibration devices
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/169Exploration, location of contaminated surface areas in situ measurement, e.g. floor contamination monitor
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/10Luminescent dosimeters
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/1048Monitoring, verifying, controlling systems and methods
    • A61N5/1075Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
    • A61N2005/1076Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T7/00Details of radiation-measuring instruments
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T5/00Recording of movements or tracks of particles; Processing or analysis of such tracks

Similar Documents

Publication Publication Date Title
Watanabe et al. Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications
Kron et al. Dosimetry of ionising radiation in modern radiation oncology
Underwood et al. Application of the Exradin W1 scintillator to determine Ediode 60017 and microDiamond 60019 correction factors for relative dosimetry within small MV and FFF fields
Schellhammer et al. experimental verification of magnetic field‐induced beam deflection and Bragg peak displacement for MR‐integrated proton therapy
Anderson et al. Microdosimetric measurements of a clinical proton beam with micrometer‐sized solid‐state detector
Mancosu et al. Evaluation of a synthetic single‐crystal diamond detector for relative dosimetry on the Leksell Gamma Knife Perfexion radiosurgery system
Knežević et al. Comparison of response of passive dosimetry systems in scanning proton radiotherapy—a study using paediatric anthropomorphic phantoms
Hermida‐López Calculation of dose distributions for 12 106Ru/106Rh ophthalmic applicator models with the PENELOPE Monte Carlo code
Kim et al. Feasibility of isodose‐shaped scintillation detectors for the measurement of gamma knife output factors
McDonald et al. Calibration of the Gamma Knife Perfexion using TG‐21 and the solid water Leksell dosimetry phantom
Chung et al. Development of a PMMA phantom as a practical alternative for quality control of gamma knife® dosimetry
Verbeek et al. Single pencil beam benchmark of a module for Monte Carlo simulation of proton transport in the PENELOPE code
Moradi et al. Dose mapping inside a gamma irradiator measured with doped silica fibre dosimetry and Monte Carlo simulation
Johnstone et al. Characterization of a plastic scintillating detector for the small animal radiation research platform (SARRP)
Rossi et al. Monte Carlo and experimental high dose rate 192Ir brachytherapy dosimetry with microDiamond detectors
Barrett et al. Monte Carlo calculated correction factors for the PTW microDiamond detector in the Gamma Knife‐Model C
Mares et al. Neutron radiation dose measurements in a scanning proton therapy room: can parents remain near their children during treatment?
Teke et al. Monte Carlo validation of the TrueBeam 10XFFF phase–space files for applications in lung SABR
Fan et al. Determination of output factors for stereotactic radiosurgery beams
Costa et al. A comprehensive Monte Carlo study of CT dose metrics proposed by the AAPM Reports 111 and 200
Kim et al. A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor
Episkopakis et al. Relative profile measurements in 1.5 T MR-linacs: investigation of central axis deviations
Girardi et al. Small field correction factors determination for several active detectors using a Monte Carlo method in the Elekta Axesse linac equipped with circular cones
Hršak et al. Correction of measured Gamma-Knife output factors for angular dependence of diode detectors and PinPoint ionization chamber
Zhang Monte Carlo simulation of mixed neutron-gamma radiation fields and dosimetry devices