Effects of the induction-gap parameters on the signal in a double-GEM detectorGuedes et al., 2003
View PDF- Document ID
- 1608978868024644102
- Author
- Guedes G
- Breskin A
- Chechik R
- Mörmann D
- Publication year
- Publication venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
External Links
Snippet
A study of a dual-GEM detector coupled to a strip readout anode is described. The effects of the induction electric field and GEM-to-anode gap are presented, for an operation in atmospheric pressure Ar/CO2 (70/30) and Ar/CH4 (95/5). Visible gain and anode signal …
- 230000000694 effects 0 title abstract description 13
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2921—Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras
- G01T1/2935—Static instruments for imaging the distribution of radioactivity in one or two dimensions; Radio-isotope cameras using ionisation detectors
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
- G01T1/241—Electrode arrangements, e.g. continuous or parallel strips or the like
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/185—Measuring radiation intensity with ionisation chamber arrangements
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Chechik et al. | Thick GEM-like multipliers—a simple solution for large area UV-RICH detectors | |
Patra et al. | Measurement of basic characteristics and gain uniformity of a triple GEM detector | |
CA2908043C (en) | Tissue equivalent proportional counter | |
Guedes et al. | Two-dimensional GEM imaging detector with delay-line readout | |
Maia et al. | Advances in the micro-hole & strip plate gaseous detector | |
Tudisco et al. | A new large area monolithic silicon telescope | |
Wang et al. | Readout for a large area neutron sensitive microchannel plate detector | |
Chechik et al. | First results on the GEM operated at low gas pressures | |
Guedes et al. | Effects of the induction-gap parameters on the signal in a double-GEM detector | |
Sarvestani et al. | Study and application of hole structures as gas gain devices for two dimensional high rate X-ray detectors | |
Buzulutskov et al. | Further studies of the GEM photomultiplier | |
Büttner et al. | Progress with the gas electron multiplier | |
Liu et al. | A study of thinner-THGEM, with some applications | |
Ezeribe et al. | Demonstration of ThGEM-multiwire hybrid charge readout for directional dark matter searches | |
Diepold et al. | Improved x-ray detection and particle identification with avalanche photodiodes | |
Garty et al. | Single photoelectron detection with a low-pressure gas electron multiplier coupled to a CsI photocathode | |
Cornelius et al. | Ion beam induced charge characterisation of a silicon microdosimeter using a heavy ion microprobe | |
Leidner et al. | Energy calibration of the GEMPix in the energy range of 6 keV to 2 MeV | |
Fernandes et al. | Excess noise factor in large area avalanche photodiodes for different temperatures | |
Fang et al. | Remark on a promising subtraction readout for pixelated CZT detectors | |
Qiu et al. | New trapezoid-shaped Frisch-grid ionization chamber for low-energy particle measurements | |
Cortesi et al. | Development of a cold-neutron imaging detector based on thick gaseous electron multiplier | |
Bougamont et al. | A large tracking detector for low-energy ions | |
Russo et al. | Characterization of 600-μm-thick SI-GaAs detectors for medical imaging | |
Bachmann et al. | Optimisation of the gas electron multiplier for high rate applications |