Hoshi et al., 2020 - Google Patents
Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Plant—1: Laboratory study on the dosemeter position and the shielding effect of full face mask …Hoshi et al., 2020
- Document ID
- 15634256945955945845
- Author
- Hoshi K
- Yoshitomi H
- Aoki K
- Tanimura Y
- Tsujimura N
- Yokoyama S
- Publication year
- Publication venue
- Radiation Measurements
External Links
Snippet
We conducted an eye lens dosimetry study on workers, engaged in recovery and decommissioning operations at Fukushima Daiichi Nuclear Power Station. To investigate the optimal positioning of eye lens dosemeters and the shielding effect of full face mask …
- 230000000694 effects 0 title abstract description 14
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/10—Luminescent dosimeters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/06—Glass dosimeters using colour change; including plastic dosimeters
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N2005/1092—Details
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
-
- G—PHYSICS
- G21—NUCLEAR PHYSICS; NUCLEAR ENGINEERING
- G21F—PROTECTION AGAINST X-RADIATION, GAMMA RADIATION, CORPUSCULAR RADIATION OR PARTICLE BOMBARDMENT; TREATING RADIOACTIVELY CONTAMINATED MATERIAL; DECONTAMINATION ARRANGEMENTS THEREFOR
- G21F1/00—Shielding characterised by the composition of the materials
- G21F1/02—Selection of uniform shielding materials
- G21F1/06—Ceramics; Glasses; Refractories
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Soares et al. | Dosimetry of beta‐ray ophthalmic applicators: comparison of different measurement methods | |
Vynckier et al. | Supplement to the code of practice for clinical proton dosimetry | |
Palmer et al. | Verification of high dose rate brachytherapy dose distributions with EBT3 Gafchromic film quality control techniques | |
Scarboro et al. | Energy response of optically stimulated luminescent dosimeters for non-reference measurement locations in a 6 MV photon beam | |
EP3286581B1 (en) | Personal dosimeter comprising at least two ionizing radiation detectors | |
Marre et al. | Comparison of p‐type commercial electron diodes for in vivo dosimetry | |
Pappas et al. | On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning | |
Hanson et al. | Physical aspects of quality assurance in radiation therapy | |
Yogo et al. | Practical use of a plastic scintillator for quality assurance of electron beam therapy | |
Delbaere et al. | On the conversion from dose-to-medium to dose-to-water in heterogeneous phantoms with Acuros XB and Monte Carlo calculations | |
Hoshi et al. | Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Plant—1: Laboratory study on the dosemeter position and the shielding effect of full face mask respirators | |
Sayeg et al. | A new method for characterizing beta‐ray ophthalmic applicator sources | |
Mazonakis et al. | Peripheral dose measurements for 6 and photon beams on a linear accelerator with multileaf collimator | |
Szermerski et al. | Dose rate constants for the quantity Hp (3) for frequently used radionuclides in nuclear medicine | |
Santos et al. | Evaluation of conversion coefficients relating air-kerma to H*(10) using primary and transmitted x-ray spectra in the diagnostic radiology energy range | |
Hertel et al. | Neutron dose coefficients for the lens of the eye | |
CN207675952U (en) | A kind of novel electronic type personnel dosimeter for photon radiation field | |
Höfel et al. | Suitability of superficial electron paramagnetic resonance dosimetry for in vivo measurement and verification of cumulative total doses during IMRT: a proof of principle | |
Lu et al. | Calculation of conversion coefficients using Chinese adult reference phantoms for air submersion and ground contamination | |
Tsujimura et al. | Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Plant—2: field study using humanoid phantoms | |
Choi et al. | Application of MOSkin detector for in vivo dosimetry on total skin electron therapy (TSET) | |
Hansen et al. | A convex windowless extrapolation chamber to measure surface dose rate from 106Ru/106Rh episcleral plaques | |
Yokoyama et al. | Radiation exposure to the lens of the eye for Japanese nuclear power plant workers | |
Shiraishi et al. | Dose estimation by ESR on tooth enamel from two workers exposed to radiation due to the JCO accident | |
Darafsheh | On energy dependency, spectral properties, and orientation dependency of EBT3, EBT-XD, MD-V3, and HD-V2 radiochromic films |