Carl et al., 2014 - Google Patents
Characterization and mitigation of cooling fan installation penalties in 1U enterprise class serversCarl et al., 2014
- Document ID
- 12661656605932160667
- Author
- Carl R
- Lawless P
- Decker J
- Publication year
- Publication venue
- 2014 Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)
External Links
Snippet
Almost all enterprise class 1U servers utilize active air cooling to maintain component temperatures. Despite a trend toward more efficient server components, the use of active cooling is still prevalent. Since the fans are a significant contributor to the power draw as …
- 238000009434 installation 0 title abstract description 28
Classifications
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/18—Packaging or power distribution
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F17/00—Digital computing or data processing equipment or methods, specially adapted for specific functions
- G06F17/50—Computer-aided design
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| US8248783B2 (en) | Heat dissipation system | |
| Ashrafi et al. | Delay of rotating stall in compressors using plasma actuators | |
| US8848363B2 (en) | Heat dissipation system | |
| CN102841660A (en) | Computer cooling system | |
| US20140036439A1 (en) | Electronic device | |
| CN104915320A (en) | GPU (Graphic Processing Unit) server | |
| CN106561074A (en) | Server cabinet assembly and temperature control method | |
| Huang et al. | Performance analysis and optimized design of backward-curved airfoil centrifugal blowers | |
| US8880225B2 (en) | Data center cooling control | |
| Hu et al. | Separation control by slot jet in a critically loaded compressor cascade | |
| Corsini et al. | Numerical assessment of fan-ducting coupling for gas turbine ventilation systems | |
| Altafi et al. | Entropy generation rate analysis of turbocharger radial flow compressor in range from surge to choke | |
| CN102841663A (en) | Computer radiating system | |
| Carl et al. | Characterization and mitigation of cooling fan installation penalties in 1U enterprise class servers | |
| Moghadam et al. | Numerical analysis of the acoustic field of a ducted axial fan at varying tip clearances | |
| Beitelmal | Numerical investigation of data center raised-floor plenum | |
| CN102541154A (en) | Rack type server | |
| Chu et al. | Impact of overhead air supply layout on the thermal performance of a container data center | |
| Zhang et al. | Flow and noise characteristics of centrifugal fan under different stall conditions | |
| Ghenaiet | Turbomachinery performance degradation due to erosion effect | |
| Park et al. | Aerodynamic Characteristics of a Cooling Fan in a Low-voltage Electric Motor | |
| Khalili et al. | Impact of Fans Location on the Cooling Efficiency of IT Servers | |
| US20140187141A1 (en) | Heat dissipation apparatus for expansion base | |
| Mariam et al. | Thermal design considerations of air-cooled high powered telecommunication cabinets | |
| Narimani et al. | Evaluation of cooling air distribution system at Amirkabir University’s high-speed data processing center |