Characterization and mitigation of cooling fan installation penalties in 1U enterprise class servers

Carl et al., 2014

Document ID
12661656605932160667
Author
Carl R
Lawless P
Decker J
Publication year
Publication venue
2014 Semiconductor Thermal Measurement and Management Symposium (SEMI-THERM)

External Links

Snippet

Almost all enterprise class 1U servers utilize active air cooling to maintain component temperatures. Despite a trend toward more efficient server components, the use of active cooling is still prevalent. Since the fans are a significant contributor to the power draw as …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/16Constructional details or arrangements
    • G06F1/20Cooling means
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/16Constructional details or arrangements
    • G06F1/18Packaging or power distribution
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F17/00Digital computing or data processing equipment or methods, specially adapted for specific functions
    • G06F17/50Computer-aided design

Similar Documents

Publication Publication Date Title
US8248783B2 (en) Heat dissipation system
Ashrafi et al. Delay of rotating stall in compressors using plasma actuators
US8848363B2 (en) Heat dissipation system
CN102841660A (en) Computer cooling system
US20140036439A1 (en) Electronic device
CN104915320A (en) GPU (Graphic Processing Unit) server
CN106561074A (en) Server cabinet assembly and temperature control method
Huang et al. Performance analysis and optimized design of backward-curved airfoil centrifugal blowers
US8880225B2 (en) Data center cooling control
Hu et al. Separation control by slot jet in a critically loaded compressor cascade
Corsini et al. Numerical assessment of fan-ducting coupling for gas turbine ventilation systems
Altafi et al. Entropy generation rate analysis of turbocharger radial flow compressor in range from surge to choke
CN102841663A (en) Computer radiating system
Carl et al. Characterization and mitigation of cooling fan installation penalties in 1U enterprise class servers
Moghadam et al. Numerical analysis of the acoustic field of a ducted axial fan at varying tip clearances
Beitelmal Numerical investigation of data center raised-floor plenum
CN102541154A (en) Rack type server
Chu et al. Impact of overhead air supply layout on the thermal performance of a container data center
Zhang et al. Flow and noise characteristics of centrifugal fan under different stall conditions
Ghenaiet Turbomachinery performance degradation due to erosion effect
Park et al. Aerodynamic Characteristics of a Cooling Fan in a Low-voltage Electric Motor
Khalili et al. Impact of Fans Location on the Cooling Efficiency of IT Servers
US20140187141A1 (en) Heat dissipation apparatus for expansion base
Mariam et al. Thermal design considerations of air-cooled high powered telecommunication cabinets
Narimani et al. Evaluation of cooling air distribution system at Amirkabir University’s high-speed data processing center