Cardiovascular toxicity as a result of radiological imagingSweni et al., 2015
- Document ID
- 11986694330636819393
- Author
- Sweni S
- Meenakshisundaram R
- Thirumalaikolundusubramanian P
- Publication year
- Publication venue
- Heart and Toxins
External Links
Snippet
The increasing use of medical imaging in cardiology practice, especially with increasing utilization of nuclear cardiology, mandates the importance of awareness of cardiac toxicity from radiological imaging. Radiation can be ionizing from X-ray or computed tomography …
- 238000003384 imaging method 0 title abstract description 32
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
- A61B6/481—Diagnostic techniques involving the use of contrast agents
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/504—Clinical applications involving diagnosis of blood vessels, e.g. by angiography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
- A61B6/507—Clinical applications involving determination of haemodynamic parameters, e.g. perfusion CT
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K49/00—Preparations for testing in vivo
- A61K49/04—X-ray contrast preparations
- A61K49/0409—Physical forms of mixtures of two different X-ray contrast-enhancing agents, containing at least one X-ray contrast-enhancing agent which is not a halogenated organic compound
- A61K49/0414—Particles, beads, capsules or spheres
- A61K49/0423—Nanoparticles, nanobeads, nanospheres, nanocapsules, i.e. having a size or diameter smaller than 1 micrometer
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K49/00—Preparations for testing in vivo
- A61K49/04—X-ray contrast preparations
- A61K49/0433—X-ray contrast preparations containing an organic halogenated X-ray contrast-enhancing agent
- A61K49/0447—Physical forms of mixtures of two different X-ray contrast-enhancing agents, containing at least one X-ray contrast-enhancing agent which is a halogenated organic compound
- A61K49/0457—Semi-solid forms, ointments, gels, hydrogels
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
- A61B8/48—Diagnostic techniques
- A61B8/481—Diagnostic techniques involving the use of contrast agent, e.g. micro-bubbles introduced into the bloodstream
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N1/00—Electrotherapy; Circuits therefor
- A61N1/18—Applying electric currents by contact electrodes
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K49/00—Preparations for testing in vivo
- A61K49/06—Nuclear magnetic resonance [NMR] contrast preparations; Magnetic resonance imaging [MRI] contrast preparations
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/44—Constructional features of the device for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K31/00—Medicinal preparations containing organic active ingredients
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K51/00—Preparations containing radioactive substances for use in therapy or testing in vivo
- A61K51/12—Preparations containing radioactive substances for use in therapy or testing in vivo characterised by a special physical form, e.g. emulsion, microcapsules, liposomes, characterized by a special physical form, e.g. emulsions, dispersions, microcapsules
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61K—PREPARATIONS FOR MEDICAL, DENTAL, OR TOILET PURPOSES
- A61K41/00—Medicinal preparations obtained by treating materials with wave energy or particle radiation; Therapies using these preparations
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| JP6791915B2 (en) | System and computer program products | |
| Cousins et al. | ICRP publication 120: radiological protection in cardiology | |
| Chida et al. | Relationship between fluoroscopic time, dose–area product, body weight, and maximum radiation skin dose in cardiac interventional procedures | |
| Li et al. | Impact of myocardial contrast echocardiography on vascular permeability: comparison of three different contrast agents | |
| Miller et al. | Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats | |
| Dix et al. | Comparison of intravenous coronary angiography using synchrotron radiation with selective coronary angiography | |
| Powell Jr et al. | Detection of edema associated with myocardial ischemia by computerized tomography in isolated, arrested canine hearts. | |
| DE102008034020A1 (en) | Contrast agent enhanced radiotherapy with high performance tubes | |
| Badea et al. | Contrast enhanced ultrasonography (CEUS) in the characterization of tumor microcirculation. Validation of the procedure in the animal experimental model. | |
| Sweni et al. | Cardiovascular toxicity as a result of radiological imaging | |
| Lieber et al. | Functional angiography | |
| Rumberger et al. | Ultrafast cardiac CT scanning | |
| Mohn et al. | Saline bolus for negative contrast perfusion imaging in magnetic particle imaging | |
| Tu et al. | Quantitative dosimetric assessment for effect of gold nanoparticles as contrast media on radiotherapy planning | |
| Fye | Coronary arteriography--it took a long time! | |
| Su et al. | Real-time myocardial contrast echocardiography in rat: infusion versus bolus administration | |
| Mahmood et al. | Combined rest thallium-201/stress technetium-99m-tetrofosmin SPECT: Feasibility and diagnostic accuracy of a 90-minute protocol | |
| Lumia et al. | MDCT evaluation of the cardiac venous system | |
| Nishizawa et al. | Blood flow of human soft tissue sarcomas measured by thallium-201 scanning: prediction of tumor response to radiation | |
| Lipton et al. | Computed tomography for patient management in coronary artery disease | |
| RU2772636C1 (en) | Method for examining patients with suspected inflammation in the wall of the ascending aorta with aneurysmal dilation | |
| Botvinick | Breast attenuation artifacts in Tl-201 scintigraphy | |
| Kuon et al. | ECG-gated coronary angiography enables submillisievert imaging in invasive cardiology | |
| Manninen et al. | Implantation of CRT pacemaker during pregnancy: estimated fetal radiation dose | |
| van Rongen | International workshop “effects of static magnetic fields relevant to human health”: Rapporteurs report: dosimetry and volunteer studies |