Busse et al., 2010 - Google Patents
Flexible add‐on solution for MR image‐guided interventions in a closed‐bore scanner environmentBusse et al., 2010
- Document ID
- 11902452547429831328
- Author
- Busse H
- Garnov N
- Thörmer G
- Zajonz D
- Gründer W
- Kahn T
- Moche M
- Publication year
- Publication venue
- Magnetic resonance in medicine
External Links
Snippet
MRI is of great clinical utility for the guidance of various diagnostic and therapeutic procedures. In a standard closed‐bore scanner, the simplest approach is to manipulate the instrument outside the bore and move the patient into the bore for reference and control …
- 230000004807 localization 0 abstract description 27
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/44—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
- G01R33/48—NMR imaging systems
- G01R33/54—Signal processing systems, e.g. using pulse sequences, Generation or control of pulse sequences ; Operator Console
- G01R33/56—Image enhancement or correction, e.g. subtraction or averaging techniques, e.g. improvement of signal-to-noise ratio and resolution
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/38—Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/055—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves involving electronic or nuclear magnetic resonance, e.g. magnetic resonance imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B17/34—Trocars; Puncturing needles
- A61B17/3403—Needle locating or guiding means
- A61B2017/3405—Needle locating or guiding means using mechanical guide means
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B17/00—Surgical instruments, devices or methods, e.g. tourniquets
- A61B2017/00831—Material properties
- A61B2017/00902—Material properties transparent or translucent
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B8/00—Diagnosis using ultrasonic, sonic or infrasonic waves
Similar Documents
Publication | Publication Date | Title |
---|---|---|
Kondziolka et al. | A comparison between magnetic resonance imaging and computed tomography for stereotactic coordinate determination | |
Lefranc et al. | The impact of the reference imaging modality, registration method and intraoperative flat-panel computed tomography on the accuracy of the ROSA® stereotactic robot | |
Tokuda et al. | In-bore setup and software for 3T MRI-guided transperineal prostate biopsy | |
Rothgang et al. | Rapid freehand MR‐guided percutaneous needle interventions: an image‐based approach to improve workflow and feasibility | |
Pagoulatos et al. | Interactive 3D registration of ultrasound and magnetic resonance images based on a magnetic position sensor | |
Fischbach et al. | MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients | |
De Oliveira et al. | Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation | |
JPH03267054A (en) | Stationary lobotomy aid | |
Moche et al. | Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients | |
Mert et al. | Advanced cranial navigation | |
Elayaperumal et al. | Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle | |
Busse et al. | Techniques for interventional MRI guidance in closed-bore systems | |
Busse et al. | Flexible add‐on solution for MR image‐guided interventions in a closed‐bore scanner environment | |
Song et al. | Biopsy needle artifact localization in MRI-guided robotic transrectal prostate intervention | |
Reichert et al. | GantryMate: a modular MR-compatible assistance system for MR-guided needle interventions | |
Yamada et al. | Magnetic resonance and ultrasound image‐guided navigation system using a needle manipulator | |
Vahala et al. | Registration in interventional procedures with optical navigator | |
Garnov et al. | Suitability of miniature inductively coupled RF coils as MR‐visible markers for clinical purposes | |
Busse et al. | Method for automatic localization of MR‐visible markers using morphological image processing and conventional pulse sequences: Feasibility for image‐guided procedures | |
Shokrollahi et al. | Ultrasonic motor-induced geometric distortions in magnetic resonance images | |
Pan et al. | Integration and evaluation of a gradient-based needle navigation system for percutaneous MR-guided interventions | |
Friebe et al. | In-room ultrasound fusion combined with fully compatible 3D-printed holding arm–rethinking interventional MRI | |
Seimenis et al. | An approach for preoperative planning and performance of MR-guided interventions demonstrated with a manual manipulator in a 1.5 T MRI scanner | |
Watanabe et al. | Evaluation of errors influencing accuracy in image-guided neurosurgery | |
Viard et al. | Needle positioning in interventional MRI procedure: real time optical localisation and accordance with the roadmap |