Rasmussen et al., 2007 - Google Patents
Cooling Strategies for IT Wiring Closets and Small RoomsRasmussen et al., 2007
View PDF- Document ID
- 10773853507338730325
- Author
- Rasmussen N
- Standley B
- Publication year
- Publication venue
- American Power Conversion
External Links
Snippet
Cooling for IT wiring closets is rarely planned and typically only implemented after failures or overheating occur. Historically, no clear standard exists for specifying sufficient cooling to achieve predictable behavior within wiring closets. An appropriate specification for cooling …
- 238000001816 cooling 0 title abstract description 64
Classifications
-
- F—MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING ENGINES OR PUMPS
- F24—HEATING; RANGES; VENTILATING
- F24F—AIR-CONDITIONING, AIR-HUMIDIFICATION, VENTILATION, USE OF AIR CURRENTS FOR SCREENING
- F24F11/00—Control or safety systems or apparatus
- F24F11/0009—Electrical control or safety systems or apparatus
- F24F11/0086—Control systems or circuits characterised by other control features, e.g. display or monitoring devices
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
Similar Documents
Publication | Publication Date | Title |
---|---|---|
US7962769B1 (en) | Balancing of renewable power usage and workload performance between cooling system and electronic components | |
Cho et al. | Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions: Case study | |
KR102431708B1 (en) | Control device for air conditioning and control method therefor | |
EP1488305B1 (en) | Improvements in cooling of a data centre | |
US9476657B1 (en) | Controlling data center cooling systems | |
CA2831972C (en) | Manufactured data center | |
US9563216B1 (en) | Managing power between data center loads | |
Allerhand et al. | Energy and thermal comfort performance evaluation of PCM ceiling panels for cooling a renovated office room | |
Chicherin | Amount of heat available from a prosumer of a 5th generation district heating and cooling (5GDHC) system: Case study of a data center | |
Todorovic et al. | Data centre's energy efficiency optimization and greening—case study methodology and R&D needs | |
Lin et al. | Data center temperature rise during a cooling system outage | |
Bhatia | HVAC cooling systems for data centers | |
Rasmussen et al. | Cooling Strategies for IT Wiring Closets and Small Rooms | |
Schmidt et al. | Evolution of Data Center Environmental Guidelines. | |
Patterson et al. | The state of datacenter cooling | |
Niemann | Hot aisle vs. cold aisle containment | |
CN207113094U (en) | A kind of heat dissipation system for computer room and data center | |
Zavrel et al. | Simulation of a data center cooling system in an emergency situation | |
Anderson | Improving data center efficiency | |
Romadhon et al. | Optimization of cooling systems in data centre by computational fluid dynamics model and simulation | |
Sisk et al. | Energy efficient cooling strategies for telecom | |
WO2018197887A1 (en) | Energy management system | |
Sullivan et al. | Reducing bypass airflow is essential for eliminating computer room hot spots | |
Hu et al. | Research on the Green Development of the HVAC Industry | |
Kinoshita et al. | Optimization of operational conditions for air-conditioning systems with aisle capping method |