Huang, 2021 - Google Patents
Monte Carlo evaluation of a LYSO‐based Compton camera using two origin ensemble algorithms with resolution recoveryHuang, 2021
- Document ID
- 10554443838708649033
- Author
- Huang H
- Publication year
- Publication venue
- Medical Physics
External Links
Snippet
Purpose Due to the lack of depth‐of‐interaction information, a Compton camera made of lutetium‐yttrium orthosilicate (LYSO) crystals suffers from poor spatial resolution, which may lead to an unreliable range verification in proton therapy. The aim of this study is to evaluate …
- 238000011084 recovery 0 title abstract description 13
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Penfold et al. | Total variation superiorization schemes in proton computed tomography image reconstruction | |
| US9207193B2 (en) | Systems and methodologies for proton computed tomography | |
| Yao et al. | Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy | |
| Andreyev et al. | Resolution recovery for Compton camera using origin ensemble algorithm | |
| Mackin et al. | The effects of Doppler broadening and detector resolution on the performance of three‐stage Compton cameras | |
| Muñoz et al. | A spectral reconstruction algorithm for two-plane Compton cameras | |
| Kohlhase et al. | Capability of MLEM and OE to detect range shifts with a Compton camera in particle therapy | |
| Jan et al. | Use of a LYSO‐based Compton camera for prompt gamma range verification in proton therapy | |
| Hilaire et al. | Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation | |
| Yao et al. | Dose reconstruction with Compton camera during proton therapy via subset-driven origin ensemble and double evolutionary algorithm | |
| Kim et al. | Background reduction in PET by double Compton scattering of quantum entangled annihilation photons | |
| Li et al. | Simultaneous reduction of radiation dose and scatter for CBCT by using collimators | |
| Wang et al. | Monte Carlo‐based adaptive EPID dose kernel accounting for different field size responses of imagers | |
| Hu et al. | Characterizing a novel scintillating glass for application to megavoltage cone‐beam computed tomography | |
| Rault et al. | Fast simulation of yttrium‐90 bremsstrahlung photons with GATE | |
| Huang | Monte Carlo evaluation of a LYSO‐based Compton camera using two origin ensemble algorithms with resolution recovery | |
| Chen et al. | TomoTherapy MLC verification using exit detector data | |
| Song et al. | Development and evaluation of a model‐based downscatter compensation method for quantitative I‐131 SPECT | |
| Yoon et al. | GPU‐based prompt gamma ray imaging from boron neutron capture therapy | |
| Sun et al. | Evaluation of the feasibility and quantitative accuracy of a generalized scatter 2D PET reconstruction method | |
| Wei et al. | Evaluation of quantitative, efficient image reconstruction for VersaPET, a compact PET system | |
| Blake et al. | A high DQE water‐equivalent EPID employing an array of plastic‐scintillating fibers for simultaneous imaging and dosimetry in radiotherapy | |
| Kozani et al. | J-PET application as a Compton camera for proton beam range verification: a preliminary study | |
| De Beenhouwer et al. | Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET | |
| Kangasmaa et al. | Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation |