[go: up one dir, main page]

Huang, 2021 - Google Patents

Monte Carlo evaluation of a LYSO‐based Compton camera using two origin ensemble algorithms with resolution recovery

Huang, 2021

Document ID
10554443838708649033
Author
Huang H
Publication year
Publication venue
Medical Physics

External Links

Snippet

Purpose Due to the lack of depth‐of‐interaction information, a Compton camera made of lutetium‐yttrium orthosilicate (LYSO) crystals suffers from poor spatial resolution, which may lead to an unreliable range verification in proton therapy. The aim of this study is to evaluate …
Continue reading at aapm.onlinelibrary.wiley.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • G01T1/2985In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/16Measuring radiation intensity
    • G01T1/161Application in the field of nuclear medicine, e.g. in vivo counting
    • G01T1/164Scintigraphy
    • G01T1/1641Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/02Dosimeters
    • G01T1/026Semiconductor dose-rate meters
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/103Treatment planning systems

Similar Documents

Publication Publication Date Title
Penfold et al. Total variation superiorization schemes in proton computed tomography image reconstruction
US9207193B2 (en) Systems and methodologies for proton computed tomography
Yao et al. Compton-based prompt gamma imaging using ordered origin ensemble algorithm with resolution recovery in proton therapy
Andreyev et al. Resolution recovery for Compton camera using origin ensemble algorithm
Mackin et al. The effects of Doppler broadening and detector resolution on the performance of three‐stage Compton cameras
Muñoz et al. A spectral reconstruction algorithm for two-plane Compton cameras
Kohlhase et al. Capability of MLEM and OE to detect range shifts with a Compton camera in particle therapy
Jan et al. Use of a LYSO‐based Compton camera for prompt gamma range verification in proton therapy
Hilaire et al. Proton therapy monitoring by Compton imaging: influence of the large energy spectrum of the prompt-γ radiation
Yao et al. Dose reconstruction with Compton camera during proton therapy via subset-driven origin ensemble and double evolutionary algorithm
Kim et al. Background reduction in PET by double Compton scattering of quantum entangled annihilation photons
Li et al. Simultaneous reduction of radiation dose and scatter for CBCT by using collimators
Wang et al. Monte Carlo‐based adaptive EPID dose kernel accounting for different field size responses of imagers
Hu et al. Characterizing a novel scintillating glass for application to megavoltage cone‐beam computed tomography
Rault et al. Fast simulation of yttrium‐90 bremsstrahlung photons with GATE
Huang Monte Carlo evaluation of a LYSO‐based Compton camera using two origin ensemble algorithms with resolution recovery
Chen et al. TomoTherapy MLC verification using exit detector data
Song et al. Development and evaluation of a model‐based downscatter compensation method for quantitative I‐131 SPECT
Yoon et al. GPU‐based prompt gamma ray imaging from boron neutron capture therapy
Sun et al. Evaluation of the feasibility and quantitative accuracy of a generalized scatter 2D PET reconstruction method
Wei et al. Evaluation of quantitative, efficient image reconstruction for VersaPET, a compact PET system
Blake et al. A high DQE water‐equivalent EPID employing an array of plastic‐scintillating fibers for simultaneous imaging and dosimetry in radiotherapy
Kozani et al. J-PET application as a Compton camera for proton beam range verification: a preliminary study
De Beenhouwer et al. Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET
Kangasmaa et al. Evaluation of quantitative 123I and 131I SPECT with Monte Carlo-based down-scatter compensation