Recent Progress in Wireless Sensors for Wearable Electronics
<p>Components in wireless, wearable sensor systems and their representative applications.</p> "> Figure 2
<p>Wireless power supply technologies for wearable sensors. (<b>a</b>) Expanded view of the magnetic field in tissue multilayers, revealing propagating waves that converge on the coil (linear scale) (Reproduced with permission [<a href="#B24-sensors-19-04353" class="html-bibr">24</a>]). (<b>b</b>) Theoretical, numerically simulated, and measured power received by a 2-mm diameter coil as a function of distance when coupling 500 mW into the tissue (Reproduced with permission [<a href="#B24-sensors-19-04353" class="html-bibr">24</a>]). (<b>c</b>) Circuit diagram of wireless power receiver with voltage amplifier (Reproduced with permission [<a href="#B25-sensors-19-04353" class="html-bibr">25</a>]. Copyright 2015, John Wiley and Sons). (<b>d</b>) Resonant cavity powers a wireless device in a mouse on the surface of the cavity (Reproduced with permission [<a href="#B26-sensors-19-04353" class="html-bibr">26</a>]. Copyright 2015, Springer Nature). (<b>e</b>) Calculated light power density across the width of the behavioral area above the resonant cavity (Reproduced with permission [<a href="#B26-sensors-19-04353" class="html-bibr">26</a>]. Copyright 2015, Springer Nature). (<b>f</b>) Photograph of dual-antenna system configured for full-body readout on a mattress, with inset of a subject lying on top of a ~5-cm-thick pad that covers the antennas. Subject: 27 years of age, male, 90 kg (Reproduced with permission [<a href="#B27-sensors-19-04353" class="html-bibr">27</a>]. Copyright 2018, American Association for the Advancement of Science). (<b>g</b>) Block diagram of the electrical working principles. LDO, low-dropout regulator; µC, microcontroller (Reproduced with permission [<a href="#B28-sensors-19-04353" class="html-bibr">28</a>]. Copyright 2018, Springer Nature). (<b>h</b>) The optical output intensity of a regulated implant at 3 and 9 cm height in a single primary antenna (power 8 W in a 30 cm × 30 cm cage). a.u., arbitrary units (Reproduced with permission [<a href="#B28-sensors-19-04353" class="html-bibr">28</a>]. Copyright 2018, Springer Nature). (<b>i</b>) Electricity generation mechanism of the contact-separation TENG (Reproduced with permission [<a href="#B29-sensors-19-04353" class="html-bibr">29</a>]. Copyright 2019, Elsevier).</p> "> Figure 3
<p>Physical sensors with wireless functions. (<b>a</b>) Top: photograph of AgNW/PI temperature sensor is attached to the skin near biceps. Bottom: temperature recorded by the temperature sensor and IR thermometer during biceps workout (Reproduced with permission [<a href="#B87-sensors-19-04353" class="html-bibr">87</a>]. Copyright 2019, American Chemical Society). (<b>b</b>) Illustration of a collection of thin, conformable skin-mounted sensors distributed across the body, with continuous, wireless transmission of temperature and pressure data in a time-multiplexed fashion. Inset: Top-view photograph of a representative sensor (Reproduced with permission [<a href="#B27-sensors-19-04353" class="html-bibr">27</a>]. Copyright 2018, The American Association for the Advancement of Science). (<b>c</b>) Exploded view schematic illustration of the device structure (Reproduced with permission [<a href="#B27-sensors-19-04353" class="html-bibr">27</a>]. Copyright 2018, The American Association for the Advancement of Science). (<b>d</b>) Post-operative monitoring of arterial pulsations after surgery (Reproduced with permission [<a href="#B44-sensors-19-04353" class="html-bibr">44</a>]. Copyright 2019, Springer Nature). (<b>e</b>) Sensing concept. The arterial pulsation results in a change in vessel diameter that is measured by the capacitive pulse sensor mounted around the artery. The change in capacitance results in a shift of the resonance frequency of the RLC circuit. This shift is measured wirelessly through the skin using an external reader coil (Reproduced with permission [<a href="#B44-sensors-19-04353" class="html-bibr">44</a>]. Copyright 2019, Springer Nature). (<b>f</b>) Schematic diagram of triboelectric nanogenerator (top). Schematic diagram of the working principle of self-powered ultrasensitive pulse sensor (bottom) (Reproduced with permission [<a href="#B88-sensors-19-04353" class="html-bibr">88</a>]. Copyright 2017, John Wiley and Sons). (<b>g</b>) Top: The optical image of bee wings on the pulse sensor, with the output performance driven by the bee wings (frequency, ≈ 200 Hz) display on the oscilloscope in real time. Bottom: The output voltage of the pulse sensor with the extremely high frequency of 10 kHz (Reproduced with permission [<a href="#B88-sensors-19-04353" class="html-bibr">88</a>]. Copyright 2017, John Wiley and Sons).</p> "> Figure 4
<p>Chemical sensors with wireless functions. (<b>a</b>) Reagent layer of the chemically modified printed Prussian-Blue carbon working electrode containing uricase for SUA biosensor (Reproduced with permission [<a href="#B112-sensors-19-04353" class="html-bibr">112</a>]. Copyright 2015, Elsevier). (<b>b</b>) Real-time continuous monitoring according to the glucose concentrations (inset, calibration curves of the glucose sensor) (Reproduced under the terms of the CC BY-NC license [<a href="#B3-sensors-19-04353" class="html-bibr">3</a>]. Copyright 2018, the authors, The American Association for the Advancement of Science). (<b>c</b>) Potentiometric performance of the pH sensor (Reproduced with permission [<a href="#B115-sensors-19-04353" class="html-bibr">115</a>]. Copyright 2018, Elsevier). (<b>d</b>) schematic of the sensing element and wireless readout. A magnified illustration is binding of pathogenic bacteria by peptides self-assembled on the graphene nanotransducer (Reproduced with permission [<a href="#B116-sensors-19-04353" class="html-bibr">116</a>]. Copyright 2012, Springer Nature). (<b>e</b>) Schematic of broad-side coupled split-ring resonators with an interlayer of silk film or responsive hydrogel. Interlayers swell and absorb surrounding solvent (changing thickness and dielectric constant) and result in a change in resonant frequency and amplitude of the sensor. Inset: Trilayer sensor adhered to a human subject’s tooth for in vivo monitoring of ingested fluids (Reproduced with permission [<a href="#B18-sensors-19-04353" class="html-bibr">18</a>]. Copyright 2018, John Wiley and Sons). (<b>f</b>) Thin interlayer (≈ 1.2 µm) response on Subject 1 to various liquids. Changes to frequency and magnitude are seen in each case (Reproduced with permission [<a href="#B18-sensors-19-04353" class="html-bibr">18</a>]. Copyright 2018, John Wiley and Sons). (<b>g</b>) Schematic illustration of the transparent, flexible alcohol sensor integrated with a wireless antenna (Reproduced with permission [<a href="#B71-sensors-19-04353" class="html-bibr">71</a>]. Copyright 2018, Elsevier). (<b>h</b>) The experimental results (reflection value, S11) of the wireless sensor before and after exposure to the ethanol vapor of 95, 238, 476, 952 ppb (Reproduced with permission [<a href="#B71-sensors-19-04353" class="html-bibr">71</a>]. Copyright 2018, Elsevier). (<b>i</b>) Photograph of an NFC tag modified with printed PTS-PAni (Reproduced with permission [<a href="#B117-sensors-19-04353" class="html-bibr">117</a>]. Copyright 2018, American Chemical Society). (<b>j</b>) The circuit of the modified NFC tag. The amine gas released from spoiled meat dedopes PTS-PAni and increases the resistance of the device and thus switches the readability of the NFC tag (Reproduced with permission [<a href="#B117-sensors-19-04353" class="html-bibr">117</a>]. Copyright 2018, American Chemical Society).</p> "> Figure 5
<p>Electrophysiological sensors with wireless functions. (<b>a</b>) Schematic overview of bioelectronic recording. Upon firing of APs, electrically active neurons inject charges into extracellular media with the corresponding extracellular potential and local field potential. The resultant potential V<sub>e</sub> within electrolytic tissue media applied on the electrolyte-electrode interface is transmitted via electronic interconnects and recorded as the output signal, V<sub>rec</sub> (Reproduced under the terms of CC BY-NC license [<a href="#B129-sensors-19-04353" class="html-bibr">129</a>]. Copyrights 2019, Royal Society of Chemistry). (<b>b</b>) Equivalent circuit diagram of the interface (Randles circuit) between the sensing electrodes and the biological system. (<b>c</b>) Optical image of 300 nm dry, thin-film electrode laminated on artificial skin. The right side of the image shows the bare artificial skin, while the left side shows the laminated sensor (Reproduced with permission [<a href="#B130-sensors-19-04353" class="html-bibr">130</a>]. Copyright 2018, John Wiley and Sons). (<b>d</b>) A series of ECG spikes measured with 300 nm thin film (top, red), and wet adhesive Ag/AgCl gel (bottom, blue) sensors (Reproduced with permission [<a href="#B130-sensors-19-04353" class="html-bibr">130</a>]. Copyright 2018, John Wiley and Sons). (<b>e</b>) Multimodal sensing suit composed of EMG and ECG sensors with wireless transmission module for long-term continuous monitoring of physiological activities (Reproduced with permission [<a href="#B131-sensors-19-04353" class="html-bibr">131</a>]. Copyright 2019, American Chemical Society). (<b>f</b>) Schematic illustration of wireless, battery-free modules for recording ECG data. The ionic liquid in the microfluidic channel contains blue dye for visualization purposes (Reproduced under the terms of CC BY license [<a href="#B132-sensors-19-04353" class="html-bibr">132</a>]. Copyright 2019, the authors, American Association for the Advancement of Science). (<b>g</b>) neonatal intensive care unit setting with a binodal (chest and foot) deployment of skin-like wireless devices designed to provide the same functionality and measurement fidelity (Reproduced under the terms of CC BY license [<a href="#B132-sensors-19-04353" class="html-bibr">132</a>]. Copyright 2019, the authors, American Association for the Advancement of Science). (<b>h</b>) Top: ECG signals acquired simultaneously from an ECG sensor (blue) and a gold standard (red), with detected peaks (green). Bottom: Respiration rate extracted from oscillations of the amplitudes of peaks extracted from the ECG waveforms (Reproduced under the terms of CC BY license [<a href="#B132-sensors-19-04353" class="html-bibr">132</a>]. Copyright 2019, the authors, American Association for the Advancement of Science).</p> "> Figure 6
<p>Electronic skins. (<b>a</b>) Overview of the system with sensors wirelessly communicating values to the display (Reproduced with permission [<a href="#B137-sensors-19-04353" class="html-bibr">137</a>]. Copyright 2018, Springer Nature). (<b>b</b>) Self-cleanable, transparent, and attachable ionic communicators were attached on the fingers and connected with wires to a controller board. A different order of a binary system was assigned to each finger, and the letters were pre-coded in the microcontroller (Reproduced with permission [<a href="#B138-sensors-19-04353" class="html-bibr">138</a>] Copyright 2018, Springer Nature). (<b>c</b>) Block diagram of the communicator based on STAICs. STAICs were connected to a controller board which contains an RC low-pass filter, a microcontroller, and a Wi-Fi module (Reproduced with permission [<a href="#B138-sensors-19-04353" class="html-bibr">138</a>] Copyright 2018, Springer Nature). (<b>d</b>) Top: A photo of the assembled ECG e-tattoo. Photos of a wireless e-tattoo with LED worn on the skin powered by a wireless NFC reader concealed beneath the white paper: compressed. Bottom: A picture of the battery-free ECG e-tattoo applied at the lower rib cage of a male subject (Reproduced with permission [<a href="#B53-sensors-19-04353" class="html-bibr">53</a>]. Copyright 2019, John Wiley and Sons). (<b>e</b>) Schematic illustrating the exploded view of the complete hybrid battery-free system. PI, polyimide; S.R., sweat rate (Reproduced under the terms of the CC BY-NC license [<a href="#B139-sensors-19-04353" class="html-bibr">139</a>]. Copyright 2019, the authors, published by The American Association for the Advancement of Science). (<b>f</b>) A phone interface that illustrates wireless communication and image acquisition (Reproduced under the terms of the CC BY-NC license [<a href="#B139-sensors-19-04353" class="html-bibr">139</a>]. Copyright 2019, the authors, published by The American Association for the Advancement of Science).</p> "> Figure 7
<p>Smart contact lenses. (<b>a</b>) The contact lens sensor with sensing elements embedded in a silicone rubber contact lens (Reproduced with permission [<a href="#B140-sensors-19-04353" class="html-bibr">140</a>]. Copyright 2014, Elsevier). (<b>b</b>) The inductance of the coil as a linear function of the average coil diameter (Reproduced with permission [<a href="#B140-sensors-19-04353" class="html-bibr">140</a>]. Copyright 2014, Elsevier). (<b>c</b>) A photograph of the contact lens sensor. Scale bar, 1 cm. (Inset: a close-up image of the antenna on the contact lens (Reproduced under the terms of the CC BY license [<a href="#B45-sensors-19-04353" class="html-bibr">45</a>]. Copyright 2017, Springer Nature). (<b>d</b>) Schematic of the wearable contact lens sensor, integrating the glucose sensor and intraocular pressure sensor (Reproduced under the terms of the CC BY license [<a href="#B45-sensors-19-04353" class="html-bibr">45</a>]. Copyright 2017, Springer Nature). (<b>e</b>) Photographs of the sensor transferred onto the contact lens worn by a bovine eyeball (Left). Wireless recording of the reflection coefficients at different pressures (Right) (Reproduced under the terms of the CC BY license [<a href="#B45-sensors-19-04353" class="html-bibr">45</a>]. Copyright 2017, Springer Nature). (<b>f</b>) Photograph of the fabricated soft, smart contact lens (Reproduced under the terms of the CC BY-NC license [<a href="#B3-sensors-19-04353" class="html-bibr">3</a>]. Copyright 2018, the authors, American Association for the Advancement of Science). (<b>g</b>) Photographs of the in vivo test on a live rabbit using the soft, smart contact lens. Left: Turn-on state of the LED in the soft, smart contact lens mounted on the rabbit’s eye. Middle: Injection of tear fluids with a glucose concentration of 0.9 mM. Right: Turn-off state of the LED after detecting the increased glucose concentration (Reproduced under the terms of the CC BY-NC license [<a href="#B3-sensors-19-04353" class="html-bibr">3</a>]. Copyright 2018, the authors, American Association for the Advancement of Science).</p> "> Figure 8
<p>Neural interfaces (<b>a−g</b>) and physiological monitoring devices (<b>h−j</b>). (<b>a</b>) Implanted flexible ECoG electrode. A photo of the flexible electrode array placed on the left hemisphere of the brain of a Sprague-Dawley rat (Reproduced under the terms of CC BY license [<a href="#B141-sensors-19-04353" class="html-bibr">141</a>]. Copyrights 2017, the authors, Springer Nature). (<b>b</b>) Mappings of ECoG signal amplitudes from a rat brain under normal state and epilepsy state. The red area has the highest amplitude, i.e. most active under epilepsy (Reproduced under the terms of CC BY license [<a href="#B141-sensors-19-04353" class="html-bibr">141</a>]. Copyrights 2017, the authors, Springer Nature). (<b>c</b>) Schematic illustration of distributed wireless ECoG recording systems with intra-skin communication (ISCOM) (Reproduced under the terms of CC BY license [<a href="#B171-sensors-19-04353" class="html-bibr">171</a>]. Copyright 2018, MDPI AG. e) Reproduced under the terms of CC BY-NC license [<a href="#B144-sensors-19-04353" class="html-bibr">144</a>]. Copyright 2018, the authors, American Association for the Advancement of Science). (<b>d</b>) Schematic illustration of a wireless ECoG sensor (Reproduced under the terms of CC BY license [<a href="#B171-sensors-19-04353" class="html-bibr">171</a>]. Copyright 2018, MDPI AG. e) Reproduced under the terms of CC BY-NC license [<a href="#B144-sensors-19-04353" class="html-bibr">144</a>]. Copyright 2018, the authors, American Association for the Advancement of Science). (<b>e</b>) Top: Device schematic of the 32-channel Au/PEDOT: PSS nanomesh MEA. Bottom: Microscope image of a Au/PEDOT: PSS bilayer-nanomesh microelectrode (left) and a SEM image of a zoomed-in region of the microelectrode (right). (<b>f</b>) Monkey with a wireless system performing a task using pure brain control (Reproduced with permission [<a href="#B145-sensors-19-04353" class="html-bibr">145</a>]. Copyright 2014, Springer Nature). (<b>g</b>) first three principal components of neural activity for six different behaviors in a monkey. Principal-component analysis data were used for support vector machine classification (Reproduced with permission [<a href="#B145-sensors-19-04353" class="html-bibr">145</a>]. Copyright 2014, Springer Nature). (<b>h</b>) Integrated wireless, battery-free oximeters in operation mode with illuminating LEDs (Reproduced under the terms of CC BY-NC license [<a href="#B15-sensors-19-04353" class="html-bibr">15</a>]. Copyrights 2019, the authors, American Association for the Advancement of Science). (<b>i</b>) Photograph of an integrated sensing patch and a block diagram of the wireless readout circuit (Reproduced under the terms of CC BY license [<a href="#B146-sensors-19-04353" class="html-bibr">146</a>]. Copyright 2016, Springer Nature). (<b>j</b>) The platform consists of an optoelectronic stimulation and sensing (OESS) module and a low-modulus, stretchable strain gauge (SG) with integrated LEDs that wraps around the bladder to monitor changes in its volume and to provide optogenetic stimulation to the neurons that innervate the bladder (Reproduced with permission [<a href="#B147-sensors-19-04353" class="html-bibr">147</a>], Copyright 2019, Springer Nature).</p> "> Figure 9
<p>Retinal prostheses. <span class="html-italic">(</span><b>a</b>) Schematic illustration of a neural prosthesis system with an external camera and internal electrode arrays (Argus II System) (Reproduced under the terms of CC BY-NC-ND license []. Copyright 2016, American Academy of Ophthalmology). (<b>b</b>) Schematic illustration of a fully-internal neural prosthesis system (Alpha-IMS system). PD: photodetector (Reproduced with permission [<a href="#B179-sensors-19-04353" class="html-bibr">179</a>]. Copyright 2014, Oxford University Press). (<b>c</b>) Motivation for a 3D subretinal prosthesis. Degenerated RCS retinas exhibit near-complete loss of photoreceptors at P120, which are replaced by debris (≈ 30 <span class="html-italic">μ</span>m thick), separating the inner nuclear layer (INL) from RPE. Such separation between the subretinal electrodes and target neurons in INL reduces stimulation efficacy (i). Pillar electrodes (30 µm tall) can bypass debris and more effectively deliver electric field to the target cells (ii) (Reproduced with permission [<a href="#B152-sensors-19-04353" class="html-bibr">152</a>]. Copyright 2014, IOP Publishing). (<b>d</b>) Fabricated liquid crystal polymer-based retinal prosthesis with three-dimensionally integrated circuit (Reproduced with permission [<a href="#B148-sensors-19-04353" class="html-bibr">148</a>]. Copyright 2015, IEEE). (<b>e</b>) The retinal prosthesis after one year of implantation showing well recovered ocular tissues (left) and showing no adverse effect such as retinal inflammation by optical coherence tomography (right) (Reproduced with permission [<a href="#B148-sensors-19-04353" class="html-bibr">148</a>]. Copyright 2015, IEEE). (<b>f</b>) The optical camera image of the phototransistor array with a truncated icosahedron design on a planar substrate. Inset shows a schematic illustration of the device structure (Reproduced under the terms of CC BY license [<a href="#B149-sensors-19-04353" class="html-bibr">149</a>]. Copyright 2017, Springer Nature). (<b>g</b>) Photograph of lens-shaped retinal prostheses. Four anchoring wings with holes are present for attaching the prosthesis with retinal tacks (Reproduced under the terms of CC BY license [<a href="#B182-sensors-19-04353" class="html-bibr">182</a>]. Copyright 2018, Springer Nature). (<b>h</b>) Representative single-sweep recording from a retinal ganglion cell over PDMS–photovoltaic interface upon 10-ms illumination at 1081.7 µW mm<sup>−</sup><sup>2</sup>. The red dotted line is the threshold set for spike detection. The green bar represents the light pulse. The blue insert shows a magnification of the period around the light pulse. The asterisk indicates the over-threshold spike detected, while the gray arrows are the on-set and off-set stimulation artifacts (Reproduced under the terms of CC BY license [<a href="#B182-sensors-19-04353" class="html-bibr">182</a>]. Copyright 2018, Springer Nature).</p> ">
Abstract
:1. Introduction
2. Wireless Technologies for Sensors Systems
2.1. Wireless Power Supply
2.1.1. Wireless Power Transfer
2.1.2. Energy Harvesting
2.2. Wireless Data Communication
2.2.1. Radiofrequency Identification (RFID)
2.2.2. Bluetooth
2.2.3. Near-Field Communication (NFC)
2.2.4. Zigbee
2.2.5. Resonant Antenna
2.2.6. Optical Communication
3. Recent Developments of Wireless Sensors
3.1. Physical Sensors
3.1.1. Temperature Sensors
3.1.2. Tactile Pressure Sensors
3.1.3. Optical Sensors
3.2. Chemical Sensors
3.2.1. Amperometric Sensors
3.2.2. Potentiometric Sensors
3.2.3. Radiofrequency-Based Sensors
3.3. Electrophysiological Sensors
4. Applications of Wireless Sensors
4.1. Electronic Skins
4.2. Smart Contact Lenses
4.3. Neural Interfaces
4.4. Physiological Monitoring Devices
4.5. Retinal Prostheses
5. Prospects
6. Conclusions
Author Contributions
Funding
Acknowledgments
Conflicts of Interest
References
- Bariya, M.; Nyein, H.Y.Y.; Javey, A. Wearable sweat sensors. Nat. Electron. 2018, 1, 160–171. [Google Scholar] [CrossRef]
- Gao, W.; Emaminejad, S.; Nyein, H.Y.Y.; Challa, S.; Chen, K.; Peck, A.; Fahad, H.M.; Ota, H.; Shiraki, H.; Kiriya, D.; et al. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature 2016, 529, 509–514. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Park, J.; Kim, J.; Kim, S.-Y.; Cheong, W.H.; Jang, J.; Park, Y.-G.; Na, K.; Kim, Y.-T.; Heo, J.H.; Lee, C.Y.; et al. Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays. Sci. Adv. 2018, 4, eaap9841. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Li, C.; Cong, S.; Tian, Z.; Song, Y.; Yu, L.; Lu, C.; Shao, Y.; Li, J.; Zou, G.; Rümmeli, M.H.; et al. Flexible perovskite solar cell-driven photo-rechargeable lithium-ion capacitor for self-powered wearable strain sensors. Nano Energy 2019, 60, 247–256. [Google Scholar] [CrossRef]
- Barrett, P.M.; Komatireddy, R.; Haaser, S.; Topol, S.; Sheard, J.; Encinas, J.; Fought, A.J.; Topol, E.J. Comparison of 24-hour Holter Monitoring with 14-day Novel Adhesive Patch Electrocardiographic Monitoring. Am. J. Med. 2014, 127, 95. [Google Scholar] [CrossRef] [PubMed]
- Tison, G.H.; Sanchez, J.M.; Ballinger, B.; Singh, A.; Olgin, J.E.; Pletcher, M.J.; Vittinghoff, E.; Lee, E.S.; Fan, S.M.; Gladstone, R.A.; et al. Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch. JAMA Cardiol. 2018, 3, 409–416. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Côté-Allard, U.; Gagnon-Turcotte, G.; Laviolette, F.; Gosselin, B. A Low-Cost, Wireless, 3-D-Printed Custom Armband for sEMG Hand Gesture Recognition. Sensors 2019, 19, 2811. [Google Scholar] [CrossRef]
- Chen, D.; Pei, Q. Electronic Muscles and Skins: A Review of Soft Sensors and Actuators. Chem. Rev. 2017, 117, 11239–11268. [Google Scholar] [CrossRef] [PubMed]
- Ledesma, H.A.; Li, X.; Carvalho-de-Souza, J.L.; Wei, W.; Bezanilla, F.; Tian, B. An atlas of nano-enabled neural interfaces. Nat. Nanotechnol. 2019, 14, 645–657. [Google Scholar] [CrossRef]
- Yetisen, A.K.; Martinez-Hurtado, J.L.; Ünal, B.; Khademhosseini, A.; Butt, H. Wearables in Medicine. Adv. Mat. 2018, 30, 1706910. [Google Scholar] [CrossRef]
- Kim, K.; Park, Y.-G.; Hyun, B.G.; Choi, M.; Park, J.-U. Recent Advances in Transparent Electronics with Stretchable Forms. Adv. Mater. 2019, 31, 1804690. [Google Scholar] [CrossRef] [PubMed]
- An, B.W.; Gwak, E.-J.; Kim, K.; Kim, Y.-C.; Jang, J.; Kim, J.-Y.; Park, J.-U. Stretchable, Transparent Electrodes as Wearable Heaters Using Nanotrough Networks of Metallic Glasses with Superior Mechanical Properties and Thermal Stability. Nano Lett. 2016, 16, 471–478. [Google Scholar] [CrossRef] [PubMed]
- Choi, T.Y.; Hwang, B.-U.; Kim, B.-Y.; Trung, T.Q.; Nam, Y.H.; Kim, D.-N.; Eom, K.; Lee, N.-E. Stretchable, Transparent, and Stretch-Unresponsive Capacitive Touch Sensor Array with Selectively Patterned Silver Nanowires/Reduced Graphene Oxide Electrodes. ACS Appl. Mater. Interfaces 2017, 9, 18022–18030. [Google Scholar] [CrossRef]
- Park, Y.-G.; An, H.S.; Kim, J.-Y.; Park, J.-U. High-resolution, reconfigurable printing of liquid metals with three-dimensional structures. Sci. Adv. 2019, 5, eaaw2844. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Zhang, H.; Gutruf, P.; Meacham, K.; Montana, M.C.; Zhao, X.; Chiarelli, A.M.; Vázquez-Guardado, A.; Norris, A.; Lu, L.; Guo, Q.; et al. Wireless, battery-free optoelectronic systems as subdermal implants for local tissue oximetry. Sci. Adv. 2019, 5, eaaw0873. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Shin, K.-Y.; Lee, J.S.; Jang, J. Highly sensitive, wearable and wireless pressure sensor using free-standing ZnO nanoneedle/PVDF hybrid thin film for heart rate monitoring. Nano Energy 2016, 22, 95–104. [Google Scholar] [CrossRef]
- Cheong, W.H.; Oh, B.; Kim, S.-H.; Jang, J.; Ji, S.; Lee, S.; Cheon, J.; Yoo, S.; Lee, S.-Y.; Park, J.-U. Platform for wireless pressure sensing with built-in battery and instant visualization. Nano Energy 2019, 62, 230–238. [Google Scholar] [CrossRef]
- Tseng, P.; Napier, B.; Garbarini, L.; Kaplan, D.L.; Omenetto, F.G. Functional, RF-Trilayer Sensors for Tooth-Mounted, Wireless Monitoring of the Oral Cavity and Food Consumption. Adv. Mat. 2018, 30, 1703257. [Google Scholar] [CrossRef]
- Nie, B.; Huang, R.; Yao, T.; Zhang, Y.; Miao, Y.; Liu, C.; Liu, J.; Chen, X. Textile-Based Wireless Pressure Sensor Array for Human-Interactive Sensing. Adv. Funct. Mater. 2019, 29, 1808786. [Google Scholar] [CrossRef]
- Karalis, A.; Joannopoulos, J.D.; Soljačić, M. Efficient wireless non-radiative mid-range energy transfer. Ann. Phys. 2008, 323, 34–48. [Google Scholar] [CrossRef] [Green Version]
- Bocan, K.N.; Sejdić, E. Adaptive Transcutaneous Power Transfer to Implantable Devices: A State of the Art Review. Sensors 2016, 16, 393. [Google Scholar] [CrossRef] [PubMed]
- Ng, D.C.; Bai, S.; Yang, J.; Tran, N.; Skafidas, E. Wireless technologies for closed-loop retinal prostheses. J. Neural Eng. 2009, 6, 065004. [Google Scholar] [CrossRef] [PubMed]
- Xue, N.; Lee, J.; Foland, S.; Chang, S.P. Biocompatible polymeric wireless pressure sensor for intraocular pressure sensing application. In Proceedings of the 2011 IEEE SENSORS, Limerick, Ireland, 28−31 October 2011; pp. 1748–1751. [Google Scholar]
- Ho, J.S.; Yeh, A.J.; Neofytou, E.; Kim, S.; Tanabe, Y.; Patlolla, B.; Beygui, R.E.; Poon, A.S.Y. Wireless power transfer to deep-tissue microimplants. PNAS 2014, 111, 7974–7979. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kim, D.; Kim, D.; Lee, H.; Jeong, Y.R.; Lee, S.-J.; Yang, G.; Kim, H.; Lee, G.; Jeon, S.; Zi, G.; et al. Body-Attachable and Stretchable Multisensors Integrated with Wirelessly Rechargeable Energy Storage Devices. Adv. Mater. 2016, 28, 748–756. [Google Scholar] [CrossRef] [PubMed]
- Montgomery, K.L.; Yeh, A.J.; Ho, J.S.; Tsao, V.; Mohan Iyer, S.; Grosenick, L.; Ferenczi, E.A.; Tanabe, Y.; Deisseroth, K.; Delp, S.L.; et al. Wirelessly powered, fully internal optogenetics for brain, spinal and peripheral circuits in mice. Nature Methods 2015, 12, 969–974. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Han, S.; Kim, J.; Won, S.M.; Ma, Y.; Kang, D.; Xie, Z.; Lee, K.-T.; Chung, H.U.; Banks, A.; Min, S.; et al. Battery-free, wireless sensors for full-body pressure and temperature mapping. Sci. Transl. Med. 2018, 10, eaan4950. [Google Scholar] [CrossRef]
- Gutruf, P.; Krishnamurthi, V.; Vázquez-Guardado, A.; Xie, Z.; Banks, A.; Su, C.-J.; Xu, Y.; Haney, C.R.; Waters, E.A.; Kandela, I.; et al. Fully implantable optoelectronic systems for battery-free, multimodal operation in neuroscience research. Nat. Electron. 2018, 1, 652–660. [Google Scholar] [CrossRef]
- Qiu, H.-J.; Song, W.-Z.; Wang, X.-X.; Zhang, J.; Fan, Z.; Yu, M.; Ramakrishna, S.; Long, Y.-Z. A calibration-free self-powered sensor for vital sign monitoring and finger tap communication based on wearable triboelectric nanogenerator. Nano Energy 2019, 58, 536–542. [Google Scholar] [CrossRef]
- Jawad, A.M.; Nordin, R.; Gharghan, S.K.; Jawad, H.M.; Ismail, M. Opportunities and Challenges for Near-Field Wireless Power Transfer: A Review. Energies 2017, 10, 1022. [Google Scholar] [CrossRef]
- Moore, J.; Castellanos, S.; Xu, S.; Wood, B.; Ren, H.; Tse, Z.T.H. Applications of Wireless Power Transfer in Medicine: State-of-the-Art Reviews. Ann. Biomed. Eng. 2019, 47, 22–38. [Google Scholar] [CrossRef]
- Jeong, C.K.; Lee, J.; Han, S.; Ryu, J.; Hwang, G.-T.; Park, D.Y.; Park, J.H.; Lee, S.S.; Byun, M.; Ko, S.H.; et al. A Hyper-Stretchable Elastic-Composite Energy Harvester. Adv. Mater. 2015, 27, 2866–2875. [Google Scholar] [CrossRef] [PubMed]
- Lee, S.; Hinchet, R.; Lee, Y.; Yang, Y.; Lin, Z.-H.; Ardila, G.; Montès, L.; Mouis, M.; Wang, Z.L. Ultrathin Nanogenerators as Self-Powered/Active Skin Sensors for Tracking Eye Ball Motion. Adv. Funct. Mater. 2014, 24, 1163–1168. [Google Scholar] [CrossRef]
- Dondi, D.; Bertacchini, A.; Brunelli, D.; Larcher, L.; Benini, L. Modeling and Optimization of a Solar Energy Harvester System for Self-Powered Wireless Sensor Networks. IEEE Trans. Ind. Electron. 2008, 55, 2759–2766. [Google Scholar] [CrossRef]
- Tran, T.V.; Chung, W. High-Efficient Energy Harvester With Flexible Solar Panel for a Wearable Sensor Device. IEEE Sens. J. 2016, 16, 9021–9028. [Google Scholar] [CrossRef]
- Srbinovska, M.; Gavrovski, C.; Dimcev, V.; Krkoleva, A.; Borozan, V. Environmental parameters monitoring in precision agriculture using wireless sensor networks. J. Clean. Prod. 2015, 88, 297–307. [Google Scholar] [CrossRef]
- Leonov, V.; Gyselinckx, B.; Hoof, C.V.; Torfs, T.; Yazicioglu, R.F.; Vullers, R.J.M.; Fiorini, P. Wearable self-powered wireless devices with thermoelectric energy scavengers. In Proceedings of the 2nd European Conference Exhibition on Integration Issues of Miniaturized Systems—MOMS, MOEMS, ICS and Electronic Components, Barcelona, Spain, 9–10 April 2008; pp. 1–8. [Google Scholar]
- Rao, J.; Chen, Z.; Zhao, D.; Yin, Y.; Wang, X.; Yi, F. Recent Progress in Self-Powered Skin Sensors. Sensors 2019, 19, 2763. [Google Scholar] [CrossRef] [PubMed]
- Wen, Z.; Yang, Y.; Sun, N.; Li, G.; Liu, Y.; Chen, C.; Shi, J.; Xie, L.; Jiang, H.; Bao, D.; et al. A Wrinkled PEDOT:PSS Film Based Stretchable and Transparent Triboelectric Nanogenerator for Wearable Energy Harvesters and Active Motion Sensors. Adv. Funct. Mater. 2018, 28, 1803684. [Google Scholar] [CrossRef]
- Yu, J.; Hou, X.; Cui, M.; Zhang, S.; He, J.; Geng, W.; Mu, J.; Chou, X. Highly skin-conformal wearable tactile sensor based on piezoelectric-enhanced triboelectric nanogenerator. Nano Energy 2019, 64, 103923. [Google Scholar] [CrossRef]
- An, B.W.; Shin, J.H.; Kim, S.-Y.; Kim, J.; Ji, S.; Park, J.; Lee, Y.; Jang, J.; Park, Y.-G.; Cho, E.; et al. Smart Sensor Systems for Wearable Electronic Devices. Polymers 2017, 9, 303. [Google Scholar] [CrossRef]
- Kou, H.; Zhang, L.; Tan, Q.; Liu, G.; Dong, H.; Zhang, W.; Xiong, J. Wireless wide-range pressure sensor based on graphene/PDMS sponge for tactile monitoring. Sci. Rep. 2019, 9, 1–7. [Google Scholar] [CrossRef]
- Park, J.; Kim, J.; Kim, K.; Kim, S.-Y.; Cheong, W.H.; Park, K.; Song, J.H.; Namgoong, G.; Kim, J.J.; Heo, J.; et al. Wearable, wireless gas sensors using highly stretchable and transparent structures of nanowires and graphene. Nanoscale 2016, 8, 10591–10597. [Google Scholar] [CrossRef] [PubMed]
- Boutry, C.M.; Beker, L.; Kaizawa, Y.; Vassos, C.; Tran, H.; Hinckley, A.C.; Pfattner, R.; Niu, S.; Li, J.; Claverie, J.; et al. Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow. Nat. Biomed. Eng. 2019, 3, 47–57. [Google Scholar] [CrossRef] [PubMed]
- Kim, J.; Kim, M.; Lee, M.-S.; Kim, K.; Ji, S.; Kim, Y.-T.; Park, J.; Na, K.; Bae, K.-H.; Kyun Kim, H.; et al. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics. Nat. Commun. 2017, 8, 14997. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kim, J.; Lee, M.-S.; Jeon, S.; Kim, M.; Kim, S.; Kim, K.; Bien, F.; Hong, S.Y.; Park, J.-U. Highly Transparent and Stretchable Field-Effect Transistor Sensors Using Graphene–Nanowire Hybrid Nanostructures. Adv. Mater. 2015, 27, 3292–3297. [Google Scholar] [CrossRef]
- Na, K.; Ma, H.; Park, J.; Yeo, J.; Park, J.; Bien, F. Graphene-Based Wireless Environmental Gas Sensor on PET Substrate. IEEE Sens. J. 2016, 16, 5003–5009. [Google Scholar] [CrossRef]
- Khan, Y.; Garg, M.; Gui, Q.; Schadt, M.; Gaikwad, A.; Han, D.; Yamamoto, N.A.D.; Hart, P.; Welte, R.; Wilson, W.; et al. Flexible Hybrid Electronics: Direct Interfacing of Soft and Hard Electronics for Wearable Health Monitoring. Adv. Funct. Mater. 2016, 26, 8764–8775. [Google Scholar] [CrossRef]
- Huang, Z.; Hao, Y.; Li, Y.; Hu, H.; Wang, C.; Nomoto, A.; Pan, T.; Gu, Y.; Chen, Y.; Zhang, T.; et al. Three-dimensional integrated stretchable electronics. Nat. Electron. 2018, 1, 473–480. [Google Scholar] [CrossRef]
- Jang, J.; Hyun, B.G.; Ji, S.; Cho, E.; An, B.W.; Cheong, W.H.; Park, J.-U. Rapid production of large-area, transparent and stretchable electrodes using metal nanofibers as wirelessly operated wearable heaters. NPG Asia Mater. 2017, 9, e432. [Google Scholar] [CrossRef]
- Gil, B.; Anastasova, S.; Yang, G.Z. A Smart Wireless Ear-Worn Device for Cardiovascular and Sweat Parameter Monitoring During Physical Exercise: Design and Performance Results. Sensors 2019, 19, 1616. [Google Scholar] [CrossRef]
- Gargiulo, G.; Bifulco, P.; Cesarelli, M.; Ruffo, M.; Romano, M.; Calvo, R.A.; Jin, C.; van Schaik, A. An ultra-high input impedance ECG amplifier for long-term monitoring of athletes. Med. Devices 2010, 3, 1–9. [Google Scholar] [CrossRef] [Green Version]
- Jeong, H.; Wang, L.; Ha, T.; Mitbander, R.; Yang, X.; Dai, Z.; Qiao, S.; Shen, L.; Sun, N.; Lu, N. Modular and Reconfigurable Wireless E-Tattoos for Personalized Sensing. Adv. Mater. Technol. 2019, 4, 1900117. [Google Scholar] [CrossRef]
- Kim, J.; Banks, A.; Xie, Z.; Heo, S.Y.; Gutruf, P.; Lee, J.W.; Xu, S.; Jang, K.-I.; Liu, F.; Brown, G.; et al. Miniaturized Flexible Electronic Systems with Wireless Power and Near-Field Communication Capabilities. Adv. Funct. Mater. 2015, 25, 4761–4767. [Google Scholar] [CrossRef]
- Lee, S.P.; Ha, G.; Wright, D.E.; Ma, Y.; Sen-Gupta, E.; Haubrich, N.R.; Branche, P.C.; Li, W.; Huppert, G.L.; Johnson, M.; et al. Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring. NPJ Digital Med. 2018, 1, 1–8. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Krishnan, S.R.; Su, C.-J.; Xie, Z.; Patel, M.; Madhvapathy, S.R.; Xu, Y.; Freudman, J.; Ng, B.; Heo, S.Y.; Wang, H.; et al. Wireless, Battery-Free Epidermal Electronics for Continuous, Quantitative, Multimodal Thermal Characterization of Skin. Small 2018, 14, 1803192. [Google Scholar] [CrossRef] [PubMed]
- Llorente-Alonso, A.; Peña-Poza, J.; de Arcas, G.; García-Heras, M.; López, J.M.; Villegas, M.A. Interface electronic system for measuring air acidity with optical sensors. Sens. Actuators A Phys. 2013, 194, 67–74. [Google Scholar] [CrossRef] [Green Version]
- Lorwongtragool, P.; Sowade, E.; Watthanawisuth, N.; Baumann, R.R.; Kerdcharoen, T. A Novel Wearable Electronic Nose for Healthcare Based on Flexible Printed Chemical Sensor Array. Sensors 2014, 14, 19700–19712. [Google Scholar] [CrossRef] [Green Version]
- Lee, S.H.; Jung, S.M.; Lee, C.K.; Jeong, K.S.; Cho, G.; Yoo, S.K. Wearable ECG Monitoring System Using Conductive Fabrics and Active Electrodes. In Proceedings of the Human-Computer Interaction. Ambient, Ubiquitous and Intelligent Interaction; Jacko, J.A., Ed.; Springer: Berlin/Heidelberg, Germany, 2009; pp. 778–783. [Google Scholar]
- Yang, S.; Chen, Y.-C.; Nicolini, L.; Pasupathy, P.; Sacks, J.; Su, B.; Yang, R.; Sanchez, D.; Chang, Y.-F.; Wang, P.; et al. “Cut-and-Paste” Manufacture of Multiparametric Epidermal Sensor Systems. Adv. Mater. 2015, 27, 6423–6430. [Google Scholar] [CrossRef]
- Xu, S.; Zhang, Y.; Jia, L.; Mathewson, K.E.; Jang, K.-I.; Kim, J.; Fu, H.; Huang, X.; Chava, P.; Wang, R.; et al. Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin. Science 2014, 344, 70–74. [Google Scholar] [CrossRef]
- Kim, D.-H.; Lu, N.; Ma, R.; Kim, Y.-S.; Kim, R.-H.; Wang, S.; Wu, J.; Won, S.M.; Tao, H.; Islam, A.; et al. Epidermal Electronics. Science 2011, 333, 838–843. [Google Scholar] [CrossRef] [Green Version]
- Huang, X.; Liu, Y.; Chen, K.; Shin, W.-J.; Lu, C.-J.; Kong, G.-W.; Patnaik, D.; Lee, S.-H.; Cortes, J.F.; Rogers, J.A. Stretchable, Wireless Sensors and Functional Substrates for Epidermal Characterization of Sweat. Small 2014, 10, 3083–3090. [Google Scholar] [CrossRef]
- Rachim, V.P.; Jiang, Y.; Lee, H.-S.; Chung, W.-Y. Demonstration of long-distance hazard-free wearable EEG monitoring system using mobile phone visible light communication. Opt. Express OE 2017, 25, 713–719. [Google Scholar] [CrossRef] [PubMed]
- Kim, J.; Gutruf, P.; Chiarelli, A.M.; Heo, S.Y.; Cho, K.; Xie, Z.; Banks, A.; Han, S.; Jang, K.-I.; Lee, J.W.; et al. Miniaturized Battery-Free Wireless Systems for Wearable Pulse Oximetry. Adv. Funct. Mater. 2017, 27, 1604373. [Google Scholar] [CrossRef] [PubMed]
- Komine, T.; Nakagawa, M. Fundamental analysis for visible-light communication system using LED lights. IEEE Trans. Consumer Electron. 2004, 50, 100–107. [Google Scholar] [CrossRef]
- Sari Merilampi; Toni Björninen; Leena Ukkonen; Pekka Ruuskanen; Lauri Sydänheimo Embedded wireless strain sensors based on printed RFID tag. Sens. Rev. 2011, 31, 32–40. [CrossRef]
- Oguntala, G.; Abd-Alhameed, R.; Jones, S.; Noras, J.; Patwary, M.; Rodriguez, J. Indoor location identification technologies for real-time IoT-based applications: An inclusive survey. Comput. Sci. Rev. 2018, 30, 55–79. [Google Scholar] [CrossRef]
- Kassal, P.; Steinberg, M.D.; Steinberg, I.M. Wireless chemical sensors and biosensors: A review. Sens. Actuators B Chem. 2018, 266, 228–245. [Google Scholar] [CrossRef]
- Nappi, S.; Mazzaracchio, V.; Fiore, L.; Arduini, F.; Marrocco, G. Flexible pH Sensor for Wireless Monitoring of the Human Skin from the Medimun Distances. In Proceedings of the 2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS), Glasgow, UK, 7–9 July 2019; pp. 1–3. [Google Scholar]
- Kim, S.-Y.; Kim, J.; Cheong, W.H.; Lee, I.J.; Lee, H.; Im, H.-G.; Kong, H.; Bae, B.-S.; Park, J.-U. Alcohol gas sensors capable of wireless detection using In2O3/Pt nanoparticles and Ag nanowires. Sens. Actuators B Chem. 2018, 259, 825–832. [Google Scholar] [CrossRef]
- Tian, X.; Lee, P.M.; Tan, Y.J.; Wu, T.L.Y.; Yao, H.; Zhang, M.; Li, Z.; Ng, K.A.; Tee, B.C.K.; Ho, J.S. Wireless body sensor networks based on metamaterial textiles. Nat. Electron. 2019, 2, 243–251. [Google Scholar] [CrossRef]
- Xu, G.; Cheng, C.; Yuan, W.; Liu, Z.; Zhu, L.; Li, X.; Lu, Y.; Chen, Z.; Liu, J.; Cui, Z.; et al. Smartphone-based battery-free and flexible electrochemical patch for calcium and chloride ions detections in biofluids. Sens. Actuators B Chem. 2019, 297, 126743. [Google Scholar] [CrossRef]
- Kenry; Yeo, J.C.; Lim, C.T. Emerging flexible and wearable physical sensing platforms for healthcare and biomedical applications. Microsyst. Nanoeng. 2016, 2, 16043. [Google Scholar] [CrossRef]
- Yao, S.; Swetha, P.; Zhu, Y. Nanomaterial-Enabled Wearable Sensors for Healthcare. Adv. Healthcare Mater. 2018, 7, 1700889. [Google Scholar] [CrossRef] [PubMed]
- Jayathilaka, W.A.D.M.; Qi, K.; Qin, Y.; Chinnappan, A.; Serrano-García, W.; Baskar, C.; Wang, H.; He, J.; Cui, S.; Thomas, S.W.; et al. Significance of Nanomaterials in Wearables: A Review on Wearable Actuators and Sensors. Adv. Mater. 2019, 31, 1805921. [Google Scholar] [CrossRef] [PubMed]
- Hong, S.Y.; Lee, Y.H.; Park, H.; Jin, S.W.; Jeong, Y.R.; Yun, J.; You, I.; Zi, G.; Ha, J.S. Stretchable Active Matrix Temperature Sensor Array of Polyaniline Nanofibers for Electronic Skin. Adv. Mater. 2016, 28, 930–935. [Google Scholar] [CrossRef] [PubMed]
- Tien, N.T.; Seol, Y.G.; Dao, L.H.A.; Noh, H.Y.; Lee, N.-E. Utilizing Highly Crystalline Pyroelectric Material as Functional Gate Dielectric in Organic Thin-Film Transistors. Adv. Mater. 2009, 21, 910–915. [Google Scholar] [CrossRef]
- Trung, T.Q.; Tien, N.T.; Seol, Y.G.; Lee, N.-E. Transparent and flexible organic field-effect transistor for multi-modal sensing. Org. Electron. 2012, 13, 533–540. [Google Scholar] [CrossRef]
- Kuroda, Y.; Koshiba, Y.; Misaki, M.; Ishida, K.; Ueda, Y. Pyroelectric Response of Submicron Free-Standing Poly(vinylidene fluoride/trifluoroethylene) Copolymer Thin Films. Appl. Phys. Express 2013, 6, 021601. [Google Scholar] [CrossRef]
- Kim, D.-I.; Quang Trung, T.; Hwang, B.-U.; Kim, J.-S.; Jeon, S.; Bae, J.; Park, J.-J.; Lee, N.-E. A Sensor Array Using Multi-functional Field-effect Transistors with Ultrahigh Sensitivity and Precision for Bio-monitoring. Sci. Rep. 2015, 5, 12705. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kim, D.-H.; Wang, S.; Keum, H.; Ghaffari, R.; Kim, Y.-S.; Tao, H.; Panilaitis, B.; Li, M.; Kang, Z.; Omenetto, F.; et al. Thin, Flexible Sensors and Actuators as ‘Instrumented’ Surgical Sutures for Targeted Wound Monitoring and Therapy. Small 2012, 8, 3263–3268. [Google Scholar] [CrossRef] [PubMed]
- Webb, R.C.; Bonifas, A.P.; Behnaz, A.; Zhang, Y.; Yu, K.J.; Cheng, H.; Shi, M.; Bian, Z.; Liu, Z.; Kim, Y.-S.; et al. Ultrathin conformal devices for precise and continuous thermal characterization of human skin. Nat. Mater. 2013, 12, 938–944. [Google Scholar] [CrossRef] [PubMed]
- Jeon, J.; Lee, H.-B.; Bao, Z. Flexible Wireless Temperature Sensors Based on Ni Microparticle-Filled Binary Polymer Composites. Adv. Mater. 2013, 25, 850–855. [Google Scholar] [CrossRef]
- Harada, S.; Kanao, K.; Yamamoto, Y.; Arie, T.; Akita, S.; Takei, K. Fully Printed Flexible Fingerprint-like Three-Axis Tactile and Slip Force and Temperature Sensors for Artificial Skin. ACS Nano 2014, 8, 12851–12857. [Google Scholar] [CrossRef] [PubMed]
- Harada, S.; Honda, W.; Arie, T.; Akita, S.; Takei, K. Fully Printed, Highly Sensitive Multifunctional Artificial Electronic Whisker Arrays Integrated with Strain and Temperature Sensors. ACS Nano 2014, 8, 3921–3927. [Google Scholar] [CrossRef] [PubMed]
- Cui, Z.; Poblete, F.R.; Zhu, Y. Tailoring the Temperature Coefficient of Resistance of Silver Nanowire Nanocomposites and their Application as Stretchable Temperature Sensors. ACS Appl. Mater. Interfaces 2019, 11, 17836–17842. [Google Scholar] [CrossRef] [PubMed]
- Ouyang, H.; Tian, J.; Sun, G.; Zou, Y.; Liu, Z.; Li, H.; Zhao, L.; Shi, B.; Fan, Y.; Fan, Y.; et al. Self-Powered Pulse Sensor for Antidiastole of Cardiovascular Disease. Adv. Mater. 2017, 29, 1703456. [Google Scholar] [CrossRef]
- Trung, T.Q.; Lee, N.-E. Flexible and Stretchable Physical Sensor Integrated Platforms for Wearable Human-Activity Monitoringand Personal Healthcare. Adv. Mater. 2016, 28, 4338–4372. [Google Scholar] [CrossRef]
- Jang, J.; Oh, B.; Jo, S.; Park, S.; An, H.S.; Lee, S.; Cheong, W.H.; Yoo, S.; Park, J.-U. Human-Interactive, Active-Matrix Displays for Visualization of Tactile Pressures. Adv. Mater. Technol. 2019, 4, 1900082. [Google Scholar] [CrossRef]
- Ji, S.; Jang, J.; Cho, E.; Kim, S.-H.; Kang, E.-S.; Kim, J.; Kim, H.-K.; Kong, H.; Kim, S.-K.; Kim, J.-Y.; et al. High Dielectric Performances of Flexible and Transparent Cellulose Hybrid Films Controlled by Multidimensional Metal Nanostructures. Adv. Mater. 2017, 29, 1700538. [Google Scholar] [CrossRef]
- An, B.W.; Heo, S.; Ji, S.; Bien, F.; Park, J.-U. Transparent and flexible fingerprint sensor array with multiplexed detection of tactile pressure and skin temperature. Nat. Commun. 2018, 9, 1–10. [Google Scholar] [CrossRef]
- Bae, G.Y.; Pak, S.W.; Kim, D.; Lee, G.; Kim, D.H.; Chung, Y.; Cho, K. Linearly and Highly Pressure-Sensitive Electronic Skin Based on a Bioinspired Hierarchical Structural Array. Adv. Mater. 2016, 28, 5300–5306. [Google Scholar] [CrossRef]
- Lou, Z.; Chen, S.; Wang, L.; Jiang, K.; Shen, G. An ultra-sensitive and rapid response speed graphene pressure sensors for electronic skin and health monitoring. Nano Energy 2016, 23, 7–14. [Google Scholar] [CrossRef]
- Lin, M.-F.; Xiong, J.; Wang, J.; Parida, K.; Lee, P.S. Core-shell nanofiber mats for tactile pressure sensor and nanogenerator applications. Nano Energy 2018, 44, 248–255. [Google Scholar] [CrossRef]
- Ling, H.; Liu, S.; Zheng, Z.; Yan, F. Organic Flexible Electronics. Small Methods 2018, 2, 1800070. [Google Scholar] [CrossRef]
- Xu, K.; Lu, Y.; Takei, K. Multifunctional Skin-Inspired Flexible Sensor Systems for Wearable Electronics. Adv. Mater. Technol. 2019, 4, 1800628. [Google Scholar] [CrossRef]
- Sourav, A.; Li, Z.; Huang, Z.; Botcha, V.D.; Hu, C.; Ao, J.-P.; Peng, Y.; Kuo, H.-C.; Wu, J.; Liu, X.; et al. Large-Scale Transparent Molybdenum Disulfide Plasmonic Photodetector Using Split Bull Eye Structure. Adv. Opt. Mater. 2018, 6, 1800461. [Google Scholar] [CrossRef]
- Ballard, Z.S.; Ozcan, A. Wearable Optical Sensors. In Mobile Health: Sensors, Analytic Methods, and Applications; Rehg, J.M., Murphy, S.A., Kumar, S., Eds.; Springer International Publishing: Cham, Switzerland, 2017; pp. 313–342. ISBN 978-3-319-51394-2. [Google Scholar]
- Xie, C.; Yan, F. Flexible Photodetectors Based on Novel Functional Materials. Small 2017, 13, 1701822. [Google Scholar] [CrossRef] [PubMed]
- Tremper, K.K.; Barker, S.J. Pulse Oximetry and Oxygen Transport. In Proceedings of the Pulse Oximetry; Payne, J.P., Severinghaus, J.W., Eds.; Springer: London, UK, 1986; pp. 19–27. [Google Scholar]
- Arjan, N.; Jovanov, B. PC-Based Pulse Signal and Blood Oxygen Level Monitor. IEEESTEC 8th Conference, Nis, Serbia, 26 November 2015; pp. 139–142. [Google Scholar]
- Azhari, A.; Yoshimoto, S.; Nezu, T.; Iida, H.; Ota, H.; Noda, Y.; Araki, T.; Uemura, T.; Sekitani, T.; Morii, K. A patch-type wireless forehead pulse oximeter for SpO2measurement. In Proceedings of the 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), Turin, Italy, 19–21 October 2017; pp. 1–4. [Google Scholar]
- Ryu, G.; You, J.; Kostianovskii, V.; Lee, E.; Kim, Y.; Park, C.; Noh, Y. Flexible and Printed PPG Sensors for Estimation of Drowsiness. IEEE Trans. Electron. Devices 2018, 65, 2997–3004. [Google Scholar] [CrossRef]
- Ferrari, M.; Quaresima, V. A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application. NeuroImage 2012, 63, 921–935. [Google Scholar] [CrossRef] [PubMed]
- Bozkurt, A.; Rosen, A.; Rosen, H.; Onaral, B. A portable near infrared spectroscopy system for bedside monitoring of newborn brain. BioMed. Eng. OnLine 2005, 4, 29. [Google Scholar] [CrossRef]
- Abay, T.Y.; Kyriacou, P.A. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions. J. Clin. Monit. Comput. 2018, 32, 447–455. [Google Scholar] [CrossRef]
- Everdell, N.L.; Airantzis, D.; Kolvya, C.; Suzuki, T.; Elwell, C.E. A portable wireless near-infrared spatially resolved spectroscopy system for use on brain and muscle. Med. Eng. Phys. 2013, 35, 1692–1697. [Google Scholar] [CrossRef]
- Guo, W.; Sheng, X.; Liu, H.; Zhu, X. Development of a Multi-Channel Compact-Size Wireless Hybrid sEMG/NIRS Sensor System for Prosthetic Manipulation. IEEE Sens. J. 2016, 16, 447–456. [Google Scholar] [CrossRef]
- Abellán-Llobregat, A.; Jeerapan, I.; Bandodkar, A.; Vidal, L.; Canals, A.; Wang, J.; Morallón, E. A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration. Biosens. Bioelectron. 2017, 91, 885–891. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kim, J.; Sempionatto, J.R.; Imani, S.; Hartel, M.C.; Barfidokht, A.; Tang, G.; Campbell, A.S.; Mercier, P.P.; Wang, J. Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform. Adv. Sci. 2018, 5, 1800880. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kim, J.; Imani, S.; de Araujo, W.R.; Warchall, J.; Valdés-Ramírez, G.; Paixão, T.R.L.C.; Mercier, P.P.; Wang, J. Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics. Biosens. Bioelectron. 2015, 74, 1061–1068. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Aleeva, Y.; Maira, G.; Scopelliti, M.; Vinciguerra, V.; Scandurra, G.; Cannatà, G.; Giusi, G.; Ciofi, C.; Figà, V.; Occhipinti, L.G.; et al. Amperometric Biosensor and Front-End Electronics for Remote Glucose Monitoring by Crosslinked PEDOT-Glucose Oxidase. IEEE Sens. J. 2018, 18, 4869–4878. [Google Scholar] [CrossRef] [Green Version]
- Shiwaku, R.; Matsui, H.; Nagamine, K.; Uematsu, M.; Mano, T.; Maruyama, Y.; Nomura, A.; Tsuchiya, K.; Hayasaka, K.; Takeda, Y.; et al. A Printed Organic Circuit System for Wearable Amperometric Electrochemical Sensors. Sci. Rep. 2018, 8, 1–8. [Google Scholar] [CrossRef]
- Dang, W.; Manjakkal, L.; Navaraj, W.T.; Lorenzelli, L.; Vinciguerra, V.; Dahiya, R. Stretchable wireless system for sweat pH monitoring. Biosens. Bioelectron. 2018, 107, 192–202. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Mannoor, M.S.; Tao, H.; Clayton, J.D.; Sengupta, A.; Kaplan, D.L.; Naik, R.R.; Verma, N.; Omenetto, F.G.; McAlpine, M.C. Graphene-based wireless bacteria detection on tooth enamel. Nat. Commun. 2012, 3, 763. [Google Scholar] [CrossRef]
- Ma, Z.; Chen, P.; Cheng, W.; Yan, K.; Pan, L.; Shi, Y.; Yu, G. Highly Sensitive, Printable Nanostructured Conductive Polymer Wireless Sensor for Food Spoilage Detection. Nano Lett. 2018, 18, 4570–4575. [Google Scholar] [CrossRef]
- Parrilla, M.; Cuartero, M.; Crespo, G.A. Wearable potentiometric ion sensors. TrAC Trends Anal. Chem. 2019, 110, 303–320. [Google Scholar] [CrossRef]
- Lee, Y.; Howe, C.; Mishra, S.; Lee, D.S.; Mahmood, M.; Piper, M.; Kim, Y.; Tieu, K.; Byun, H.-S.; Coffey, J.P.; et al. Wireless, intraoral hybrid electronics for real-time quantification of sodium intake toward hypertension management. PNAS 2018, 115, 5377–5382. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Park, B.; Park, H.G.; Ji, J.; Cho, J.; Jun, S.C. A Reduced Graphene Oxide Based Radio Frequency Glucose Sensing Device Using Multi-Dimensional Parameters. Micromachines 2016, 7, 136. [Google Scholar] [CrossRef] [PubMed]
- Charkhabi, S.; Beierle, A.M.; McDaniel, M.D.; Reuel, N.F. Resonant Sensors for Low-Cost, Contact-Free Measurement of Hydrolytic Enzyme Activity in Closed Systems. ACS Sens. 2018, 3, 1489–1498. [Google Scholar] [CrossRef] [PubMed]
- Liu, S.; Meng, X.; Zhang, J.; Chae, J. A wireless fully-passive acquisition of biopotentials. Biosens. Bioelectron. 2019, 139, 111336. [Google Scholar] [CrossRef]
- Hartong, D.T.; Berson, E.L.; Dryja, T.P. Retinitis pigmentosa. Lancet 2006, 368, 1795–1809. [Google Scholar] [CrossRef]
- Thaut, M.H.; McIntosh, G.C.; Rice, R.R.; Miller, R.A.; Rathbun, J.; Brault, J.M. Rhythmic auditory stimulation in gait training for Parkinson’s disease patients. Mov. Disord. 1996, 11, 193–200. [Google Scholar] [CrossRef] [PubMed]
- Ramanathan, C.; Ghanem, R.N.; Jia, P.; Ryu, K.; Rudy, Y. Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia. Nat. Med. 2004, 10, 422–428. [Google Scholar] [CrossRef]
- Fu, R.; Luo, W.; Nazempour, R.; Tan, D.; Ding, H.; Zhang, K.; Yin, L.; Guan, J.; Sheng, X. Implantable and Biodegradable Poly(l-lactic acid) Fibers for Optical Neural Interfaces. Adv. Opt. Mater. 2018, 6, 1700941. [Google Scholar] [CrossRef]
- Lee, H.E.; Choi, J.; Lee, S.H.; Jeong, M.; Shin, J.H.; Joe, D.J.; Kim, D.; Kim, C.W.; Park, J.H.; Lee, J.H.; et al. Monolithic Flexible Vertical GaN Light-Emitting Diodes for a Transparent Wireless Brain Optical Stimulator. Adv. Mater. 2018, 30, 1800649. [Google Scholar] [CrossRef]
- Zhang, Z.; Cui, L.; Shi, X.; Tian, X.; Wang, D.; Gu, C.; Chen, E.; Cheng, X.; Xu, Y.; Hu, Y.; et al. Textile Display for Electronic and Brain-Interfaced Communications. Adv. Mater. 2018, 30, 1800323. [Google Scholar] [CrossRef]
- Yuk, H.; Lu, B.; Zhao, X. Hydrogel bioelectronics. Chem. Soc. Rev. 2019, 48, 1642–1667. [Google Scholar] [CrossRef] [PubMed]
- Nawrocki, R.A.; Jin, H.; Lee, S.; Yokota, T.; Sekino, M.; Someya, T. Self-Adhesive and Ultra-Conformable, Sub-300 nm Dry Thin-Film Electrodes for Surface Monitoring of Biopotentials. Adv. Funct. Mater. 2018, 28, 1803279. [Google Scholar] [CrossRef]
- Jin, H.; Nayeem, M.O.G.; Lee, S.; Matsuhisa, N.; Inoue, D.; Yokota, T.; Hashizume, D.; Someya, T. Highly Durable Nanofiber-Reinforced Elastic Conductors for Skin-Tight Electronic Textiles. ACS Nano 2019, 13, 7905–7912. [Google Scholar] [CrossRef] [PubMed]
- Chung, H.U.; Kim, B.H.; Lee, J.Y.; Lee, J.; Xie, Z.; Ibler, E.M.; Lee, K.; Banks, A.; Jeong, J.Y.; Kim, J.; et al. Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care. Science 2019, 363, eaau0780. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Flores, T.; Lei, X.; Huang, T.; Lorach, H.; Dalal, R.; Galambos, L.; Kamins, T.; Mathieson, K.; Palanker, D. Optimization of pillar electrodes in subretinal prosthesis for enhanced proximity to target neurons. J. Neural Eng. 2018, 15, 036011. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Yang, X.; Zhou, T.; Zwang, T.J.; Hong, G.; Zhao, Y.; Viveros, R.D.; Fu, T.-M.; Gao, T.; Lieber, C.M. Bioinspired neuron-like electronics. Nat. Mater. 2019, 18, 510–517. [Google Scholar] [CrossRef]
- Wilks, S.J.; Richardson-Burn, S.M.; Hendricks, J.L.; Martin, D.; Otto, K.J. Poly(3,4-ethylene dioxythiophene) (PEDOT) as a micro-neural interface material for electrostimulation. Front. Neuroeng. 2009, 2. [Google Scholar] [CrossRef]
- Rui, Y.; Liu, J.; Wang, Y.; Yang, C. Parylene-based implantable Pt-black coated flexible 3-D hemispherical microelectrode arrays for improved neural interfaces. Microsyst Technol 2011, 17, 437. [Google Scholar] [CrossRef]
- Son, D.; Kang, J.; Vardoulis, O.; Kim, Y.; Matsuhisa, N.; Oh, J.Y.; To, J.W.; Mun, J.; Katsumata, T.; Liu, Y.; et al. An integrated self-healable electronic skin system fabricated via dynamic reconstruction of a nanostructured conducting network. Nat. Nanotech. 2018, 13, 1057–1065. [Google Scholar] [CrossRef]
- Lee, Y.; Cha, S.H.; Kim, Y.-W.; Choi, D.; Sun, J.-Y. Transparent and attachable ionic communicators based on self-cleanable triboelectric nanogenerators. Nat. Commun. 2018, 9, 1–8. [Google Scholar] [CrossRef]
- Bandodkar, A.J.; Gutruf, P.; Choi, J.; Lee, K.; Sekine, Y.; Reeder, J.T.; Jeang, W.J.; Aranyosi, A.J.; Lee, S.P.; Model, J.B.; et al. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. Sci. Adv. 2019, 5, eaav3294. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Chen, G.-Z.; Chan, I.-S.; Leung, L.K.K.; Lam, D.C.C. Soft wearable contact lens sensor for continuous intraocular pressure monitoring. Med. Eng. Phys. 2014, 36, 1134–1139. [Google Scholar] [CrossRef] [PubMed]
- Xie, K.; Zhang, S.; Dong, S.; Li, S.; Yu, C.; Xu, K.; Chen, W.; Guo, W.; Luo, J.; Wu, Z. Portable wireless electrocorticography system with a flexible microelectrodes array for epilepsy treatment. Sci. Rep. 2017, 7, 1–8. [Google Scholar] [CrossRef] [PubMed]
- Leonardi, M.; Pitchon, E.M.; Bertsch, A.; Renaud, P.; Mermoud, A. Wireless contact lens sensor for intraocular pressure monitoring: Assessment on enucleated pig eyes. Acta Ophthalmol. 2009, 87, 433–437. [Google Scholar] [CrossRef] [PubMed]
- Chiou, J.-C.; Hsu, S.-H.; Huang, Y.-C.; Yeh, G.-T.; Liou, W.-T.; Kuei, C.-K. A Wirelessly Powered Smart Contact Lens with Reconfigurable Wide Range and Tunable Sensitivity Sensor Readout Circuitry. Sensors 2017, 17, 108. [Google Scholar] [CrossRef]
- Qiang, Y.; Artoni, P.; Seo, K.J.; Culaclii, S.; Hogan, V.; Zhao, X.; Zhong, Y.; Han, X.; Wang, P.-M.; Lo, Y.-K.; et al. Transparent arrays of bilayer-nanomesh microelectrodes for simultaneous electrophysiology and two-photon imaging in the brain. Sci. Adv. 2018, 4, eaat0626. [Google Scholar] [CrossRef] [Green Version]
- Schwarz, D.A.; Lebedev, M.A.; Hanson, T.L.; Dimitrov, D.F.; Lehew, G.; Meloy, J.; Rajangam, S.; Subramanian, V.; Ifft, P.J.; Li, Z.; et al. Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys. Nat. Methods 2014, 11, 670–676. [Google Scholar] [CrossRef] [PubMed]
- Imani, S.; Bandodkar, A.J.; Mohan, A.M.V.; Kumar, R.; Yu, S.; Wang, J.; Mercier, P.P. A wearable chemical–electrophysiological hybrid biosensing system for real-time health and fitness monitoring. Nat. Commun. 2016, 7, 1–7. [Google Scholar] [CrossRef]
- Mickle, A.D.; Won, S.M.; Noh, K.N.; Yoon, J.; Meacham, K.W.; Xue, Y.; McIlvried, L.A.; Copits, B.A.; Samineni, V.K.; Crawford, K.E.; et al. A wireless closed-loop system for optogenetic peripheral neuromodulation. Nature 2019, 565, 361–365. [Google Scholar] [CrossRef] [PubMed]
- Jeong, J.; Bae, S.H.; Min, K.S.; Seo, J.; Chung, H.; Kim, S.J. A Miniaturized, Eye-Conformable, and Long-Term Reliable Retinal Prosthesis Using Monolithic Fabrication of Liquid Crystal Polymer (LCP). IEEE Trans. Biomed. Eng. 2015, 62, 982–989. [Google Scholar] [CrossRef]
- Choi, C.; Choi, M.K.; Liu, S.; Kim, M.S.; Park, O.K.; Im, C.; Kim, J.; Qin, X.; Lee, G.J.; Cho, K.W.; et al. Human eye-inspired soft optoelectronic device using high-density MoS 2 -graphene curved image sensor array. Nat. Commun. 2017, 8, 1–11. [Google Scholar] [CrossRef]
- Flores, T.; Huang, T.; Bhuckory, M.; Ho, E.; Chen, Z.; Dalal, R.; Galambos, L.; Kamins, T.; Mathieson, K.; Palanker, D. Honeycomb-shaped electro-neural interface enables cellular-scale pixels in subretinal prosthesis. Sci. Rep. 2019, 9, 1–12. [Google Scholar] [CrossRef]
- Lorach, H.; Goetz, G.; Smith, R.; Lei, X.; Mandel, Y.; Kamins, T.; Mathieson, K.; Huie, P.; Harris, J.; Sher, A.; et al. Photovoltaic restoration of sight with high visual acuity. Nat. Med. 2015, 21, 476–482. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Kabiri Ameri, S.; Ho, R.; Jang, H.; Tao, L.; Wang, Y.; Wang, L.; Schnyer, D.M.; Akinwande, D.; Lu, N. Graphene Electronic Tattoo Sensors. ACS Nano 2017, 11, 7634–7641. [Google Scholar] [CrossRef]
- Cazalé, A.; Sant, W.; Ginot, F.; Launay, J.-C.; Savourey, G.; Revol-Cavalier, F.; Lagarde, J.M.; Heinry, D.; Launay, J.; Temple-Boyer, P. Physiological stress monitoring using sodium ion potentiometric microsensors for sweat analysis. Sens. Actuators B Chem. 2016, 225, 1–9. [Google Scholar] [CrossRef]
- Coyle, S.; Lau, K.; Moyna, N.; O’Gorman, D.; Diamond, D.; Francesco, F.D.; Costanzo, D.; Salvo, P.; Trivella, M.G.; Rossi, D.E.D.; et al. BIOTEX—Biosensing Textiles for Personalised Healthcare Management. IEEE Trans. Inf. Technol. Biomed. 2010, 14, 364–370. [Google Scholar] [CrossRef] [PubMed]
- Green, J.M.; Pritchett, R.C.; Tucker, D.C.; Crews, T.R.; McLester, J.R. Sweat lactate response during cycling at 30°C and 18°C WBGT. J. Sports Sci. 2004, 22, 321–327. [Google Scholar] [CrossRef] [PubMed]
- Martín, A.; Kim, J.; Kurniawan, J.F.; Sempionatto, J.R.; Moreto, J.R.; Tang, G.; Campbell, A.S.; Shin, A.; Lee, M.Y.; Liu, X.; et al. Epidermal Microfluidic Electrochemical Detection System: Enhanced Sweat Sampling and Metabolite Detection. ACS Sens. 2017, 2, 1860–1868. [Google Scholar] [CrossRef]
- Onor, M.; Gufoni, S.; Lomonaco, T.; Ghimenti, S.; Salvo, P.; Sorrentino, F.; Bramanti, E. Potentiometric sensor for non invasive lactate determination in human sweat. Anal. Chim. Acta 2017, 989, 80–87. [Google Scholar] [CrossRef] [PubMed]
- Cope, J.R.; Collier, S.A.; Nethercut, H.; Jones, J.M.; Yates, K.; Yoder, J.S. Risk Behaviors for Contact Lens–Related Eye Infections Among Adults and Adolescents—United States, 2016. MMWR Morb. Mortal Wkly Rep. 2017, 66, 841–845. [Google Scholar] [CrossRef]
- Kim, J.; Campbell, A.S.; de Ávila, B.E.-F.; Wang, J. Wearable biosensors for healthcare monitoring. Nat. Biotechnol. 2019, 37, 389–406. [Google Scholar] [CrossRef]
- Farandos, N.M.; Yetisen, A.K.; Monteiro, M.J.; Lowe, C.R.; Yun, S.H. Contact Lens Sensors in Ocular Diagnostics. Adv. Healthcare Mater. 2015, 4, 792–810. [Google Scholar] [CrossRef]
- Yao, H.; Shum, A.J.; Cowan, M.; Lähdesmäki, I.; Parviz, B.A. A contact lens with embedded sensor for monitoring tear glucose level. Biosens. Bioelectron. 2011, 26, 3290–3296. [Google Scholar] [CrossRef] [Green Version]
- Lahdesmaki, I.; Shum, A.J.; Parviz, B.A. Possibilities for continuous glucose monitoring by a functional contact lens. IEEE Instrum. Meas. Mag. 2010, 13, 14–17. [Google Scholar] [CrossRef]
- Yao, H.; Liao, Y.; Lingley, A.R.; Afanasiev, A.; Lähdesmäki, I.; Otis, B.P.; Parviz, B.A. A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring. J. Micromech. Microeng. 2012, 22, 075007. [Google Scholar] [CrossRef]
- Mansouri, K.; Orguel, S.; Mermoud, A.; Haefliger, I.; Flammer, J.; Ravinet, E.; Shaarawy, T. Quality of diurnal intraocular pressure control in primary open-angle patients treated with latanoprost compared with surgically treated glaucoma patients: a prospective trial. Br. J. Ophthalmol. 2008, 92, 332–336. [Google Scholar] [CrossRef] [PubMed]
- Leonardi, M.; Leuenberger, P.; Bertrand, D.; Bertsch, A.; Renaud, P. First Steps toward Noninvasive Intraocular Pressure Monitoring with a Sensing Contact Lens. Invest. Ophthalmol. Vis. Sci. 2004, 45, 3113–3117. [Google Scholar] [CrossRef] [PubMed]
- Mansouri, K.; Shaarawy, T. Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma. Br. J. Ophthalmol. 2011, 95, 627–629. [Google Scholar] [CrossRef] [PubMed]
- Dunbar, G.E.; Shen, B.Y.; Aref, A.A. The Sensimed Triggerfish contact lens sensor: efficacy, safety, and patient perspectives. Clin. Ophthalmol. 2017, 11, 875–882. [Google Scholar] [CrossRef] [PubMed]
- Carrasco, F.G.; Alonso, D.D.; Niño-de-Rivera, L. Biocompatibility and implant of a less invasive intraocular pressure sensor. Microelectron. Eng. 2016, 159, 32–37. [Google Scholar] [CrossRef]
- Graimann, B.; Allison, B.Z.; Pfurtscheller, G. Brain-Computer Interfaces: Revolutionizing Human-Computer Interaction; Springer Science Business Media: Berlin/Heidelberg, Germany, 2010; ISBN 978-3-642-02091-9. [Google Scholar]
- Parvizi, J.; Kastner, S. Promises and limitations of human intracranial electroencephalography. Nat. Neurosci. 2018, 21, 474–483. [Google Scholar] [CrossRef]
- Chang, S.; AlAshmouny, K.; McCormick, M.; Chen, Y.; Yoon, E. BioBolt: A minimally-invasive neural interface for wireless epidural recording by intra-skin communication. In Proceedings of the 2011 Symposium on VLSI Circuits—Digest of Technical Papers, Honolulu, HI, USA; 2011; pp. 146–147. [Google Scholar]
- Chang, S.-I.; Park, S.-Y.; Yoon, E. Minimally-Invasive Neural Interface for Distributed Wireless Electrocorticogram Recording Systems. Sensors 2018, 18, 263. [Google Scholar] [CrossRef]
- Borton, D.A.; Yin, M.; Aceros, J.; Nurmikko, A. An implantable wireless neural interface for recording cortical circuit dynamics in moving primates. J. Neural Eng. 2013, 10, 026010. [Google Scholar] [CrossRef] [PubMed]
- Mukhopadhyay, S.C. Wearable Sensors for Human Activity Monitoring: A Review. IEEE Sens. J. 2015, 15, 1321–1330. [Google Scholar] [CrossRef]
- Pascolini, D.; Mariotti, S.P. Global estimates of visual impairment: 2010. Br. J. Ophthalmol. 2012, 96, 614–618. [Google Scholar] [CrossRef] [PubMed]
- Zhang, K.; Zhang, L.; Weinreb, R.N. Ophthalmic drug discovery: novel targets and mechanisms for retinal diseases and glaucoma. Nat. Rev. Drug Discov. 2012, 11, 541–559. [Google Scholar] [CrossRef]
- Jager, R.D.; Mieler, W.F.; Miller, J.W. Age-Related Macular Degeneration. N. Engl. J. Med. 2008, 358, 2606–2617. [Google Scholar] [CrossRef] [Green Version]
- da Cruz, L.; Dorn, J.D.; Humayun, M.S.; Dagnelie, G.; Handa, J.; Barale, P.-O.; Sahel, J.-A.; Stanga, P.E.; Hafezi, F.; Safran, A.B.; et al. Five-Year Safety and Performance Results from the Argus II Retinal Prosthesis System Clinical Trial. Ophthalmology 2016, 123, 2248–2254. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Luo, Y.H.-L.; da Cruz, L. A review and update on the current status of retinal prostheses (bionic eye). Br. Med. Bull. 2014, 109, 31–44. [Google Scholar] [CrossRef] [Green Version]
- Lee, H.; Choi, T.K.; Lee, Y.B.; Cho, H.R.; Ghaffari, R.; Wang, L.; Choi, H.J.; Chung, T.D.; Lu, N.; Hyeon, T.; et al. A graphene-based electrochemical device with thermoresponsive microneedles for diabetes monitoring and therapy. Nat. Nanotechnol. 2016, 11, 566–572. [Google Scholar] [CrossRef]
- Eleftheriou, C.G.; Zimmermann, J.B.; Kjeldsen, H.D.; David-Pur, M.; Hanein, Y.; Sernagor, E. Carbon nanotube electrodes for retinal implants: A study of structural and functional integration over time. Biomaterials 2017, 112, 108–121. [Google Scholar] [CrossRef]
- Ferlauto, L.; Leccardi, M.J.I.A.; Chenais, N.A.L.; Gilliéron, S.C.A.; Vagni, P.; Bevilacqua, M.; Wolfensberger, T.J.; Sivula, K.; Ghezzi, D. Design and validation of a foldable and photovoltaic wide-field epiretinal prosthesis. Nat. Commun. 2018, 9, 1–15. [Google Scholar] [CrossRef] [PubMed] [Green Version]
RFID | Bluetooth | NFC | Zigbee | Resonant Antenna | Optical | |
---|---|---|---|---|---|---|
Transceiver type/Power source | Passive transponder, Battery-free or battery-assisted | Active radio, Battery power | Passive transponder, Battery-free or -assisted | Active radio, Battery power | Passive transponder, Battery-free or -assisted | Active radio, Battery power |
Operating frequency | 120~140 kHz 13.56 MHz 868~956 MHz | 2.4~5 GHz | 13.56 MHz | 868 MHz, 915 MHz, 2.4 GHz | Depending on the type of antenna | 30 kHz ~300 GHz |
Data rate | 100 kb/s | 24 MB/s | 424 kb/s | 250 kb/s | 100 kb/s | 1 Gb/s |
Working ranges | 15 m, (frequency dependent) | 10~100 m | 5 cm | 10~100 m | 1 m (typically) (frequency dependent) | 10 m |
Power consumption | Very low (passive) | Medium | Low (in passive case) | Medium | Very low (in passive case) | Relatively high |
Continuous monitoring | △ Portable, Smartphone-tagged | ○ | △ Portable, Smartphone-tagged | ○ | △ Network analyzer or amplifier required | ○ |
Sensor network | ○ | ○ | ○ | ○ | ○ | ○ |
Advantage | low power consumption | High data rate, Wide range | Low power consumption High security | Low power consumption Wide range | Low power consumption to transfer signal | Radiation-free No bandwidth regulation High data rate |
Weakness | Low data rate Short range | High power consumption Poor security | Very short range | Lowutilization | Low data rate Short range | Light interference no passes through walls |
Reference | [18,42,43,44,45,46,47] | [48,49,50,51,52] | [53,54,55,56] | [57,58,59] | [60,61,62,63] | [15,64,65,66] |
Ref. | Application | Sensing Type | Target Analytes | Power Supply | Data Communication | Features |
---|---|---|---|---|---|---|
[137] | Electronic skin | Electrophysiological/Physical | ECG/Body strain | Battery | Bluetooth | Display integrated |
[138] | Electronic skin | Physical (triboelectric sensing) | Touch | TENG | Wi-Fi | Self-powered |
[53] | Electronic skin | Electrophysiological/Physical | ECG/Skin Temperature, Hydration | Smartphone (passive type) | NFC | - |
[139] | Electronic skin | Physical/Chemical | Sweat rate/pH, Lactate, Glucose, Chloride | Smartphone (passive type) | NFC | Microfluidic platform |
[140] | Smart contact lens | Physical | Intraocular pressure | No power required | Resonant antenna | - |
[45] | Smart contact lens | Physical/Chemical | Intraocular pressure/Glucose | No power required | Resonant antenna | Fully transparent |
[3] | Smart contact lens | Chemical | Glucose | Inductive coupling | LED output | LED integrated |
[141] | Neural interface | Electrophysiological | ECoG | Battery | Bluetooth | - |
[142,143] | Neural interface | Electrophysiological | ECoG | Battery | Intraskin communication | - |
[144] | Neural interface | Electrophysiological | Neural signals | N/A | RF antenna (Ultrawideband) | - |
[145] | Neural interface | Electrophysiological | Neural signals | Battery | RF antenna (ISM band) | - |
[15] | Physiology monitoring | Optical | Tissue oxygen saturation | Resonant inductive coupling | IR | - |
[146] | Physiology monitoring | Electrophysiological, Chemical | ECG, Lactate | Battery | Bluetooth | - |
[147] | Physiology monitoring | Physical | Bladder strain | Resonant inductive coupling | Bluetooth | Stimulation function integrated |
[148] | Retinal prosthesis | Optical (camera) | Light | Battery | RF antenna | - |
[149] | Retinal prosthesis | Optical (photodetector array) | Light | Battery | N/A | - |
[150,151] | Retinal prosthesis | Optical (photovoltaic sensing) | Light | Photovoltaics | N/A | - |
© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Park, Y.-G.; Lee, S.; Park, J.-U. Recent Progress in Wireless Sensors for Wearable Electronics. Sensors 2019, 19, 4353. https://doi.org/10.3390/s19204353
Park Y-G, Lee S, Park J-U. Recent Progress in Wireless Sensors for Wearable Electronics. Sensors. 2019; 19(20):4353. https://doi.org/10.3390/s19204353
Chicago/Turabian StylePark, Young-Geun, Sangil Lee, and Jang-Ung Park. 2019. "Recent Progress in Wireless Sensors for Wearable Electronics" Sensors 19, no. 20: 4353. https://doi.org/10.3390/s19204353