[go: up one dir, main page]

Paper
29 July 2016 The latest results from DICE (Detector Interferometric Calibration Experiment)
A. Crouzier, F. Malbet, F. Hénault, A. Léger, C. Cara, J. M. Le Duigou, O. Preis, P. Kern, A. Delboulbe, G. Martin, P. Feautrier, E. Stadler, S. Lafrasse, S. Rochat, C. Ketchazo, M. Donati, Eric Doumayrou, P. O. Lagage, M. Shao, R. Goullioud, B. Nemati, C. Zhai, E. Behar, S. Potin, M. Saint-Pe, J. Dupont
Author Affiliations +
Abstract
Theia is an astrometric mission proposed to ESA in 2014 for which one of the scientific objectives is detecting Earth-like exoplanets in the habitable zone of nearby solar-type stars. This objective requires the capability to measure stellar centroids at the precision of 1x10-5 pixel. Current state-of-the-art methods for centroid estimation have reached a precision of about 3x10-5 pixel at two times Nyquist sampling, this was shown at the JPL by the VESTA experiment. A metrology system was used to calibrate intra and inter pixel quantum efficiency variations in order to correct pixelation errors. The Theia consortium is operating a testbed in vacuum in order to achieve 1x10-5 pixel precision for the centroid estimation. The goal is to provide a proof of concept for the precision requirement of the Theia spacecraft. The testbed consists of two main sub-systems. The first one produces pseudo stars: a blackbody source is fed into a large core fiber and lights-up a pinhole mask in the object plane, which is imaged by a mirror on the CCD. The second sub-system is the metrology, it projects young fringes on the CCD. The fringes are created by two single mode fibers facing the CCD and fixed on the mirror. In this paper we present the latest experiments conducted and the results obtained after a series of upgrades on the testbed was completed. The calibration system yielded the pixel positions to an accuracy estimated at 4x10-4 pixel. After including the pixel position information, an astrometric accuracy of 6 x 10-5 pixel was obtained, for a PSF motion over more than 5 pixels. In the static mode (small jitter motion of less than 1 x 10-3 pixel), a photon noise limited precision of 3x10-5 pixel was reached.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. Crouzier, F. Malbet, F. Hénault, A. Léger, C. Cara, J. M. Le Duigou, O. Preis, P. Kern, A. Delboulbe, G. Martin, P. Feautrier, E. Stadler, S. Lafrasse, S. Rochat, C. Ketchazo, M. Donati, Eric Doumayrou, P. O. Lagage, M. Shao, R. Goullioud, B. Nemati, C. Zhai, E. Behar, S. Potin, M. Saint-Pe, and J. Dupont "The latest results from DICE (Detector Interferometric Calibration Experiment)", Proc. SPIE 9904, Space Telescopes and Instrumentation 2016: Optical, Infrared, and Millimeter Wave, 99045G (29 July 2016); https://doi.org/10.1117/12.2234304
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Metrology

Stars

Sensors

Charge-coupled devices

Electroluminescent displays

Stray light

RELATED CONTENT

The VLTI fringe sensors: FINITO and PRIMA FSU
Proceedings of SPIE (October 20 2004)
Narrow-angle astrometry with PRIMA
Proceedings of SPIE (September 12 2012)
NEAT: a microarcsec astrometric telescope
Proceedings of SPIE (September 15 2011)

Back to Top