Abstract
In this paper an application of Artificial Intelligence (AI) to Medical Robotics is described. Namely, a specific AI technique is employed to generate a sequence of operations understandable by the control system of a robot which is to perform a semi-automatic surgical task. According to this technique, a planner is implemented to translate the “natural” language of the surgeon into the robotic sequence that should be executed by the robot. A robotic simulator has been implemented in order to test the planned sequence in a virtual environment. The planned sequence is then to be input to the medical robotic system, which will execute the surgical operation. The work described in this paper features a high level of originality, since no similar applications of AI to medical robotics could be found in the scientific literature.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.References
A. Austad O. J. Elle J. S. Røtnes (2001) ArticleTitleComputer-aided planning of trocar placement and robot settings in robot-assisted surgery International Congress Series 1230 1020–1026 Occurrence Handle10.1016/S0531-5131(01)00179-0
M. Autret (1996) ArticleTitleTransfer of space technology to the field of medicine Annales de Chirurgie 50 159–161
J. Beatty P. J. Biggs K. Gal P. Okunieff F. S. Pardo K. J. Harte M. J. Dalterio A. P. Sliski (1996) ArticleTitleA new miniature X-ray device for interstitial radiosurgery: Dosimetry Medical Physics 23 IssueID(1) 53–62 Occurrence Handle10.1118/1.597791
M. Cohn L. S. Crawford J. M. Wendlandt S. S. Sastry (1995) ArticleTitleSurgical applications of millirobots J. Robotic Systems 12 IssueID(6) 401–416 Occurrence Handle10.1002/rob.4620120606
Costi, G., Gallo, E., Garibotto, G., Giorgi, C., and Casolino, D.: 1995, Force feedback control of a robotic arm in neurosurgical applications, in: IX World Congress on the Theory of Machines and Mechanisms, Milan (Italy), Sept., pp. 2161–2165.
N. D’Attellis D. Loulmet A. Carpentier A. Berrebi C. Cardon R. Severac-Bastide J. Fabiani D. Safran (2002) ArticleTitleRobotic-assisted cardiac surgery: Anesthetic and postoperative considerations J. Cardiothoracic and Vascular Anesthesia 16 397–400 Occurrence Handle10.1053/jcan.2002.125154
M. Dinsmore K. J. Harte A. P. Sliski D. O. Smith P. M. Nomikos M. J. Dalterio A. J. Boom W. F. Leonard P. E. Oettinger J. C. Yanch (1996) ArticleTitleA new miniature X-ray source for interstitial radiosurgery: Device description Medical Physics 23 IssueID(1) 53–62
C. Eschenbach W. Heydrich (1995) ArticleTitleClassical mereology and restricted domains Internat. J. Human-Computer Studies 43 IssueID(5-6) 723–740 Occurrence Handle10.1006/ijhc.1995.1071
Fearing, R. S., Moy, G., and Tan, E.: 1997, Some basic issues in teletaction, in: IEEE Int. Conf. Robotics and Automation, April.
R. E. Fikes N. J Nilsson (1971) ArticleTitleStrips: A new approach to the application of theorem proving to problem solving Artificial Intelligence 2 189–208 Occurrence Handle0234.68036 Occurrence Handle10.1016/0004-3702(71)90010-5
Giorgi, C., Casolino, D. S., Ongania, E., and Sandini, G.: 1989, Intraoperative graphic workstation to plan neurosurgical procedures, in: Annual Conference on Engineering in Medicine and Biology Images of the Twenty-First Century - 11th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Seattle, USA, Nov. 9–12.
M. Fernandez-Lopez A. Gomez-Perez M.-D. Rojas-Amaya (2000) Ontology’s crossed life cycles 12th International Conference on Knowledge Engineering and Knowledge Management (EKAW00) France Juan-les-Pins 65–79
B. L. Gray R. S. Fearing (1996) ArticleTitleA surface micromachined microtactile sensor array Proceedings of 1996 IEEE International Conference on Robotics and Automation 1 1–6
S. J. Harris F. Arambula-Cosio R. D. Hibberd B. L. Davies J. E. A. Wickham M. S. Nathan B. Kund (1997) ArticleTitleThe PROBOT: An active robot for prostate resection Proc. Instr. Mech. Engrs. Part H 211 317–325
Hoffmann, J.: 2001, The fast-forward planning system, AI Magazine, 57–61.
L. R. Kavoussi R. G. Moore J. B. Adams A. W. Partin (1995) ArticleTitleComparison of robotic versus human laparoscopic camera control J. Urology 154 2134–2136 Occurrence Handle10.1016/S0022-5347(01)66715-6
C. Koneckny (1996) ArticleTitleAESOP lends a hand in the OR Today’s Surgical Nurse 18 28–32
Kukleta, J.: 1998, Use of robotics in surgery: AESOP 2000, in: Proceedings of XXXIII Congress of the European Society for Surgical Research, Padova (Italy), April.
K. Masamune M. Sonderegger H. Iseki K. Takakura M. Suzuki T. Dohi (1996) ArticleTitleRobots for stereotactic neurosurgery Advanced Robotics 10 IssueID(4) 391–401
Prisco, G. M., Avizzano, C. A., Calcara, M., Ciancio, S., Pinna, S., and Bergamasco, M.: 1998, Virtual environment with haptic feedback for the treatment of motor dexterity disabilities, in: Proceedings of the 1998 IEEE International Conference on Robotics and Automation, Leuven, Belgium, May 16–20, pp. 3721–3726.
Refanidis, I. and Vlahavas, I.: 2001, The GRT planner, AI Magazine, 63–65.
O. Reuthebuch E. Ecknauer G. Zünd M. Turina (2002) ArticleTitleTotal robotic-enhanced pericardiectomy for effusive pericarditis Interactive Cardiovascular and Thoracic Surgery 1 IssueID(2) 102–104 Occurrence Handle10.1016/S1569-9293(02)00063-4
Rodin, V. and Ayache, A.: 1993, Monocular stereovision - a medical robotic application, in: Proceedings of SPIE, Boston (USA), pp. 175–185.
J. Slaney S. Thiébaux (2001) ArticleTitleBlocks World revisited Artificial Intelligence 125 119–153 Occurrence Handle0969.68136 Occurrence Handle10.1016/S0004-3702(00)00079-5 Occurrence Handle1805644
R. H. Taylor L. Joskowicz B. Williamson A. Guéziec A. Kalvin P. Kazanzides R. Vorhis ParticleVan J. Yao R. Kumar A. Bzostek et al. (1999) ArticleTitleComputer-integrated revision total hip replacement surgery: Concept and preliminary results Medical Image Analysis 3 IssueID(3) 301–319 Occurrence Handle10.1016/S1361-8415(99)80026-7
Tendick, F. and Cavusoglu, M. C.: 1997, Human machine interfaces for minimally invasive surgery, in: Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS’97), Chicago (USA), October 30–November 2.
Troccaz, J., Lavallee, S., and Hellion, E.: 1993, Passive arm with dynamic constraints: A solution to safety problems in medical robotics?, in: Proceedings of the IEEE International Conference on Systems, Man and Cybernetics, Piscataway (USA), pp. 166–171.
G. Heijst ParticleVan A. Th. Schreiber B. J. Wielinga (1997) ArticleTitleUsing explicit ontologies in KBS development Internat. J. Human-Computer Studies 46 IssueID(2/3) 183–292 Occurrence Handle0869.68098
J. M. Wendlandt S. S. Sastry (1994) ArticleTitleDesign and control of a simplified Stewart platform for endoscopy Proceedings of the 1994 Conference on Decision and Control 1 357–362 Occurrence Handle10.1109/CDC.1994.410903
M. Winston R. Chaffin D. Herrmann (1987) ArticleTitleA taxonomy of part-wholerelations Cognitive Science 11 417–444 Occurrence Handle10.1016/S0364-0213(87)80015-0
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Alessandri, E., Gasparetto, A., Valencia Garcia, R. et al. An application of artificial intelligence to medical robotics. J Intell Robot Syst 41, 225–243 (2005). https://doi.org/10.1007/s10846-005-3509-x
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/s10846-005-3509-x