[go: up one dir, main page]

Skip to main content

Comparison of phantom target localisation by frame-based stereotaxy and by the VISLAN system

  • Brain Models and Neurosurgery
  • Conference paper
  • First Online:
CVRMed-MRCAS'97 (CVRMed 1997, MRCAS 1997)

Abstract

The VISLAN system is based on one of the newest developments in optical localiser tracking, where the localiser reflects light shone on it (passive illumination) rather than emitting light. In experiments with a CT-compatible skull phantom we evaluated the VISLAN system in comparison with a widely used stereotactic system, the Cosman-Roberts-Wells frame (Radionics Inc). The mean Euclidean difference in localising points initially defined in CT images was 2.5mm across a wide range of target positions. We estimated the accuracy of the VISLAN system with the same phantom set up but independently of the stereotactic frame, and showed a mean Euclidean error of 1.0mm. We concluded that the majority of the discrepancy between the two systems was accounted for by the inaccuracy of the CRW frame. It would be inappropriate to regard the frame based systems as a satisfactory gold standard for estimating the accuracy of VISLAN. However, frame-based and frameless guidance may be needed in the same operation, and it is important for such systems to be compared.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Adams L, Krybus W, Meyer-Ebrecht D (1990) Computer-assisted Surgery. IEEE Comp Graphics Appl, 10: 43–51.

    Article  Google Scholar 

  • Bucholz D R, Smith K R. A comparison of Sonic Digitizers Versus Light Emitting Diode-Based Localization. (1993) In: Maciunas RJ, ed. Interactive Image-Guided Neurosurgery. American Association of Neurological Surgeons, 179–200.

    Google Scholar 

  • Buurman J & Gerritsen, F A. European applications in surgical interventions (EASI) (1996) In Lemke H U et al, Proceedings of Computer Assisted Radiology. Berlin: Springer, 677–681.

    Google Scholar 

  • Colchester A C F, Evans R C, Zhao J et al (1994a) VISLAN: combining intra-operative video and preoperative images for surgical guidance. In Applications of Computer Vision in Medical Image Processing. Wells, G M (ed) AAAI Press, 235–238.

    Google Scholar 

  • Colchester A C F, Zhao J, Henri C J, et al. (1994b) Craniotomy simulation and guidance using a stereo video based tracking system (VISLAN). In Robb R A, ed. Proceedings of Visualisation in Biomedical Computing (VBC 994). Bellingham: SPIE Press, 1994:541–551.

    Google Scholar 

  • Colchester A C F, Zhao J, Holton-Tainter K S, Henri C J, Maitland N, Roberts P T E, Harris C G, Evans R J. (1996) Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging. Medical Image Analysis, 1, 73–90.

    Article  PubMed  Google Scholar 

  • Henri C J, Colchester A C F, Zhao J, Hawkes D J, Hill D L G, Evans R J. (1995) Registration of 3-D surface data for intra-operative guidance and visualisation in frameless stereotactic neurosurgery. In: Ayache N, ed. Proceedings of First International Conference on Computer Vision, Virtual Reality and Robotics in Medicine, Nice France, April 1995, Lecture Notes in Computer Science 905, 47–56.

    Google Scholar 

  • Holton-Tainter K S, Zhao J, Colchester A C F. (1995) Accuracy of the VISLAN intra-operative pointer in localising markers from pre-operative images. In: Kikinis, R. ed. Proceedings of Medical Robotics and Computer Assisted Surgery. Philadelphia: Wiley, 278–283.

    Google Scholar 

  • Maciunas R J, Fitzpatrick J M, Galloway R L, Allen G S. (1993) Beyond stereotaxy: Extreme levels of application accuracy are provided by implantable fiducial markers for interactive image-guided neurosurgery. In: Robert J. Maciunas, ed. Interactive Image-Guided Neurosurgery: American Association of Neurological Surgeons, 259–270.

    Google Scholar 

  • Maciunas R J, Galloway R C, & Latimer J W (1994) The application accuracy of stereotactic frames. Neurosurgery 35: 682–695.

    PubMed  Google Scholar 

  • Zhao J & Colchester A C F (1995) Preoperative image processing in a computer-assisted neurological planning & guidance system (VISLAN). In Lemke H U et al, Proceedings of Computer Assisted Radiology 1995. Berlin: Springer, 847–852.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Jocelyne Troccaz Eric Grimson Ralph Mösges

Rights and permissions

Reprints and permissions

Copyright information

© 1997 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Colchester, A.C.F., Zhao, J., Dorward, N., Subsol, G., Thomas, D.G.T. (1997). Comparison of phantom target localisation by frame-based stereotaxy and by the VISLAN system. In: Troccaz, J., Grimson, E., Mösges, R. (eds) CVRMed-MRCAS'97. CVRMed MRCAS 1997 1997. Lecture Notes in Computer Science, vol 1205. Springer, Berlin, Heidelberg. https://doi.org/10.1007/BFb0029273

Download citation

  • DOI: https://doi.org/10.1007/BFb0029273

  • Published:

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-62734-0

  • Online ISBN: 978-3-540-68499-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics