Abstract
Static images of the human body using electrical impedance tomography techniques can be obtained by measuring at two or more different frequencies. The frequencies used depend on the application, and their selection depends on the frequency behaviour of the impedance for the target tissue. An analysis using available data and theoretical models for tissue impedance yields the expected impedance and boundary voltage changes, therefore setting the measurement instrument specifications. The instrument errors produced by different sources are analysed, and, from this analysis it is possible to determine the feasibility of building the instrument, the limit values for some parameters (or components) and indications on the most suitable design of critical parts. This analysis also shows what kinds of error can be expected in the reconstructed images. It is concluded that it is possible to build an instrument with limited errors, allowing static images to be obtained. An instrument has been built that meets some of the design requirements and fails in others because of technological problems. In vivo images obtained with this instrument will be presented in Part 2 of this work.
Similar content being viewed by others
References
Brown, B. H., andSeagar, A. D. (1985): ‘Applied potential tomography. Data collection problems.’ IEE Int. Conf. on Electric and Magnetic Fields in Medicine and Biology, London, UK, pp. 79–82
Drago, G. P., Marchesi, M., andRidela, S. (1984): ‘The frequency dependence of an analytical model of an electrically simulated biological structure,’Bioelectromag.,5, pp. 47–62
Eyüboĝlu, B. M., Brown, B. H., andBarber, D. C. (1989): ‘In vivo imaging of cardiac related impedance changes’,IEEE Eng. Med. Biol. Mag.,8, pp. 39–45
Foster, K. R., andSchwan, H. P. (1989): ‘Dielectric properties of tissues and biological material: a review’,CRC Crit. Rev. Biomed. Eng.,17, (1), pp. 25–104
Griffiths, H., andAhmed, A. (1987): ‘A dual-frequency applied potential tomography: computer simulations’,Clin. Phys. Physiol. Meas.,8, (Suppl. A), pp. 103–107
Isaacson, D. (1986): ‘Distinguishability of conductivities by electric current computed tomography’,IEEE Trans.,MI-5, pp. 91–95
Murphy, D., andRolfe, P. (1988): ‘Aspects of instrumentation design for impedance imaging’,Clin. Phys. Physiol. Meas.,9, (Suppl. A), pp. 5–14
Newell, J. C., Isaacson, D., Cheney, M., Saulnier, G. J., Gisser, D. G., Goble, J. C., Cook, R. D., andEdic, P. M. (1992): ‘Impedance images of the chest.’ IEEE Eng. in Med. & Biol. Soc. 14th Ann. Int. Conf., Paris, France, pp. 1752‐1753
Pethig, R. (1984): ‘Dielectric properties of biological materials: biophysical and medical applications’,IEEE Trans.,EI-19, pp. 453–474
Ramo, S., Whinnery, J. R., andVan Duzer, T. (1965): ‘Campost y ondas’ (Ediciones Pirámide, Madrid, Spain)
Riu, P., Lozano, A., Fernandez, M., andPallàs-Areny, R. (1991): ‘Electrode requirements for electrical impedance tomography.’IV Int. Symp. of Biomedical Engineering, Peñiscola, Spain
Riu, P., Rosell, J., andPallàs-Areny, R. (1992): ‘In vivo static imaging for the real and the reactive parts in electrical impedance tomography using multifrequency techniques.’ IEEE Eng. in Med. & Biol. Soc. 14th Ann. Int. Conf., Paris, France, pp. 1706–1707
Riu, P., Rosell, J., andPallà-Areny, R. (1993): ‘Multifrequency electrical impedance tomography as an alternative to absolute imaging’in Beck, M. S., Campogrande, E., Morris, M., Williams, R. A., andWaterfall, R. C. (Eds.): ‘Tomographic techniques for process design and operation’, (Computational Mechanics Publications, Southampton, UK) pp. 53–62
Rosell, J., Riu, P., andPallàs-Areny, R. (1989): ‘A parallel data acquisition system for electrical impedance tomography.’ IEEE Eng. Med. & Biol. Soc. 11th Ann. Int. Conf., Seattle, USA, pp. 459–460
Rosell, J., andPallàs-Areny, R. (1991): ‘Current injection strategies in electrical impedance tomography.’ IFMBE World Congress on Medical Physics & Biomedical Engineering, Kyoto, Japan, p. 192.
Rosell, J., andRiu, P. (1992): ‘Common-mode feedback in electrical impedance tomography’,Clin. Phys. Physiol. Meas.,8, (Suppl. A), pp. 11–14
Schwan, H. P. (1957): ‘Electrical properties of tissue and cell suspensions’ inLawrence, J. H. andTobias, C. A. (Eds): ‘Advances in biological and medical physics, Vol. V’ (Academic Press, Inc., New York), p. 147
Seagar, A. D., Barber, D. C., andBrown, B. H. (1987): ‘Theoretical limits to sensitivity and resolution in impedance imaging’,Clin Phys. Physiol. Meas.,8, (Suppl. A), pp. 12–31
Yorkey, T. J., andWebster, J. G. (1987): ‘A comparison of impedance tomographic reconstruction algorithms’,Clin. Phys. Physiol. Meas.,8, (Suppl. A), pp. 55–62
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Riu, P.J., Rosell, J., Lozano, A. et al. Multi-frequency static imaging in electrical impedance tomography: Part 1 instrumentation requirements. Med. Biol. Eng. Comput. 33, 784–792 (1995). https://doi.org/10.1007/BF02523010
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF02523010