Abstract
Cavitation effects in pulsed laser ablation can cause severe deformation of tissue near the ablation site. In angioplasty, they result in a harmful dilatation and invagination of the vessel walls. We suggest to reduce cavitation effects by dividing the laser pulse energy into a pre-pulse with low and an ablation pulse with high energy. The pre-pulse creates a small cavitation bubble which can be filled by the ablation products of the main pulse. For suitable energy ratios between the pulses, this bubble will not be enlarged by the ablation products, and the maximal bubble size remains much smaller than after a single ablation pulse. The concept was analyzed by numerical calculations based on the Gilmore model of cavitation dynamics and by high-speed photography of the effects of single and double pulses performed with a silicone tube as vessel model. The use of double pulses prevents the deformation of the vessel walls. The concept works with an energy ratio of up to about 1:30 between the pulses. For the calculated optimal ratio of 1:14.6, the bubble volume is reduced by a factor of 17.7. The ablation pulse is best applied when the pre-pulse bubble is maximally expanded, but the timing is not very critical.
Similar content being viewed by others
References
A. Vogel, P. Schweiger, A. Frieser, M.N. Asiyo, R. Birngruber: IEEE J. QE-26, 2240 (1990)
A. Vogel, S. Busch, K. Jungnickel, R. Birngruber: Lasers Surg. Med.15, 32 (1994)
T. van Leeuwen, M.J. van der Veen, R.M. Verdaasdonk, C. Borst: Lasers Surg. Med.11, 26 (1991)
M.B. Preisack, W. Neu, R. Nyga, M. Wehrmann, K.K. Haase, K.R. Karsch: Lasers Surg. Med.12, 520 (1992)
T.G. van Leeuwen, L. van Erven, J.H. Meertens, M. Motamedi, J.M. Post, C. Borst: J. Am. Coll. Cardiol.19, 1610 (1992)
T.G. van Leeuwen, J.H. Meertens, E. Velema, M.J. Post, C. Borst: Circulation87, 1258 (1993)
G. Lee, D.T. Mason: Am. J. Cardiol.69, 1640 (1992)
J.A. Bittl, T.A. Sanborn: Circulation86, 71 (1992)
A.B. Buchwald, G.S. Werner, C. Unterberg, E. Voth, H. Kreuzer, V. Wiegand: Am. Heart J.123, 878 (1992)
G.S. Reeder, J.F. Bresnahan, D.R.J. Holmes, F. Litvack: Cathet. Cardiovasc. Diagn.25, 195 (1992)
T.A. Fischell, M.L. Stadius: Cathet. Cardiovasc. Diagn.22, 205 (1991)
F. Nakamura, J. Kvasnicka, Y. Uchida, H.J. Geschwind: Am. Heart J.124, 1467 (1992)
F. Litvack, N.L. Eigler, J.S. Forrester: Circulation87, 1421 (1993)
J.E. Tcheng, H.R. Phillips, L.D. Wells, R.A. Golobic, J.A. Power, L.I. Deckelbaum: J. Am. Coll. Cardiol.21, 386A (1993)
M. Oberhoff, S. Hassenstein, H. Hanke, D.Y. Xie, E. Blessing, A. Baumbach, S. Hanke, K.K. Haase, E. Betz, K.R. Karsch: Circulation86, 800 (1992)
F.R. Gilmore: Calif. Inst. Techn. Rep.26-4 (1952)
R.T. Knapp, J.W. Daily, F.G. Hammitt:Cavitation (McGraw-Hill, New York 1971) pp. 117–131
K.J. Ebeling: Acustica40, 229 (1978) (in German)
U. Grigull, J. Straub, P. Schiebner (eds.):Steam Tables in SI-Units, 3rd edn. (Springer, Berlin, Heidelberg 1990)
L.F. Shampine, M.K. Gordon:Computer Solution of Ordinary Differential Equations. The Initial Value Problem (Freeman, San Francisco 1975)
Y.C. Fung:Biomechanics - Mechanical Properties of Living Tissues, 2nd edn. (Springer, Berlin, Heidelberg 1993)
A. Vogel, W. Lauterborn: J. Acoust. Soc. Am.84, 719 (1988)
R.O. Esenaliev, A.A. Oraevsky, V.S. Letokhov, A.A. Karabutov, T.V. Malinsky: Lasers Surg. Med.13, 470 (1993)
R.S. Dingus: SPIE Proc.1646, 266 (1992)
P. Teng, N.S. Nishioka, R.R. Anderson, T.F. Deutsch: IEEE J. QE-23, 1845 (1987)
R. Fabbro, J. Fournier, P. Ballard, D. Deveaux, J. Virmont: J. Appl. Phys.68, 775 (1990)
A.G. Doukas, D.J. McAucliffe, T.J. Flotte: Ultrasound Med. Biol.19, 137 (1993)
M. Delius: Shock Waves4, 55 (1994)
M.G. Sirotyuk: InHigh Intensity Ultrasonic Fields, ed. by L.D. Rozenberg (Plenum, New York 1971) pp. 263–346
G. Paltauf, E. Reichel, H. Schmidt-Kloiber: SPIE Proc.1646, 343 (1992)
S.L. Jacques, G. Gofstein, R.S. Dingus: SPIE Proc.1646, 284 (1992)
A. Vogel, W. Hentschel, J. Holzfuß, W. Lauterborn: Ophthalmol.93, 1259 (1986)
D. Albagli, L.T. Perelman, G.S. Janes, C. von Rosenberg, I. Itzkan, M.S. Feld: Lasers Life Sci.6, 55 (1994)
L.I. Deckelbaum: Lasers Surg. Med.14, 101 (1994)
W.S. Grundfest, F. Litvack, J.S. Forrester, T. Goldenberg, H.J.C. Swan, L. Morgenstern, M. Fishbein, I.S. McDermid, D.M. Rider, T.J. Pacala, J.B. Laudenslager: J. Am. Coll. Cardiol.5, 929 (1985)
G. Laufer, G. Wollenek, K. Hohla, R. Horvat, K.H. Henke, M. Buchelt, G. Wutzl, E. Wolner: Circulation78, 1031 (1988)
M. Scheu, H. Kagel, M. Zwaan, A. Lebeau, R. Engelhardt: Lasers Surg. Med.11, 133 (1991)
T.J. Garrand, M.L. Stetz, K.M. O'Brien, G.R. Gindi, B.E. Sumpio, L.I. Deckelbaum: Lasers Surg. Med.11, 106 (1991)
M. Scheu, R. Engelhardt: SPIE Proc.1425, 63 (1991)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vogel, A., Engelhardt, R., Behnle, U. et al. Minimization of cavitation effects in pulsed laser ablation illustrated on laser angioplasty. Appl. Phys. B 62, 173–182 (1996). https://doi.org/10.1007/BF01081122
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF01081122