Indus Basin Irrigation System (IBIS) in Pakistan is the backbone of agriculture in the country. T... more Indus Basin Irrigation System (IBIS) in Pakistan is the backbone of agriculture in the country. The IBIS provides irrigation support to agricultural lands across the country; however, hydraulic efficiency of the water conveyance system is impacted due to seepage losses. The lining of irrigation channels is considered a potential solution for improving hydraulic efficiency. Therefore, this study explores the impact of canal lining on the hydraulic efficiency of the canals in the Punjab province of Pakistan. Overall, 14 channels/distributaries/minors (total length 226 km) were monitored in terms of hydraulic performance in different irrigation zones. Hydraulic, geometrical, and socioeconomic parameters of channel/distributaries/minors including roughness coefficient, sediments, flow velocity, wetted parameter, breaches, theft cases, bed, side slope, water surface profile, hydraulic radius, crop yield, and vegetation growth area have been experimentally observed. Obtained results have ...
Estimation of reference evapotranspiration (ETo) is a key element in water resources management a... more Estimation of reference evapotranspiration (ETo) is a key element in water resources management and crop water requirement which, in turn, affects irrigation scheduling. ETo is subject to the influence of various climatic parameters including minimum temperature (Tmin), maximum temperature (Tmax), relative humidity (RH), windspeed (WS), and sunshine hours (SH). Usually, the influence of the climatic parameters and a dominating climatic factor influencing ETo is estimated on yearly basis. However, in diverse climatic regions, ETo varies with the varying climate. Therefore, this study aims to estimate the spatiotemporal variation in the influence of the climatic parameters on ETo in Punjab, Pakistan, for the period 1950–2021, specifically focusing on decennial, annual, and monthly patterns. The study area was divided into five agroclimatic zones. The Penman–Monteith model was used to estimate ETo. The influence was assessed using geographic weighted regression (GWR) and multiscale geo...
In a water-scarce country such as Pakistan, rainfall is the third-largest source of freshwater. I... more In a water-scarce country such as Pakistan, rainfall is the third-largest source of freshwater. In most of the urban cities of the country, rainwater is mixed with sewerage and is rendered useless for managed aquifer recharge purposes. Therefore, this study investigates the rainfall potential for managed aquifer recharge in Lahore (Pakistan). The present research was designed and conducted by the Irrigation Research Institute (IRI). Three different sites were selected for rainwater sample collection across the study area (Lahore), ranging from urban to rural areas. The rainwater samples were collected and divided into three categories (direct capture, rooftop runoff, street runoff). For longer rainfall events, the effect of time on the quality of the collected rainwater samples was also studied. Spatiotemporal trends of turbidity, pH, electrical conductivity, total dissolved solids, carbonates, bicarbonates, chloride, calcium, magnesium, and hardness in the collected rainwater sampl...
This study reports on the investigation of the performance of single and two-stage liquid and sol... more This study reports on the investigation of the performance of single and two-stage liquid and solid desiccant dehumidification systems and two-stage combined liquid and solid desiccant dehumidification systems with reference to humid climates. The research focus is on a dehumidification system capacity of 25 kW designed for room air conditioning application using the thermal models reported in the literature. RD-type silica gel and LiCl are used as solid and liquid desiccant materials, respectively. In this study, the application of proposed system for deep drying application is also explored. Condensation rate and moisture removal efficiency are chosen as performance parameters for room air conditioning application, whereas air outlet temperature is chosen as performance parameter for deep drying application. Further, for a given range of operating parameters, influences of air inlet humidity ratio, flow rate, and inlet temperature on performance parameters of the systems are inves...
The present study provides insights into the energy-saving potential of a membrane energy recover... more The present study provides insights into the energy-saving potential of a membrane energy recovery ventilator (ERV) for the management of building air-conditioning loads. This study explores direct (DEC), Maisotsenko cycle (MEC) evaporative cooling, and vapor compression (VAC) systems with ERV. Therefore, this study aims to explore possible air-conditioning options in terms of temperature, relative humidity, human thermal comfort, wet bulb effectiveness, energy saving potential, and CO2 emissions. Eight different combinations of the above-mentioned systems are proposed in this study i.e., DEC, MEC, VAC, MEC-VAC, and their possible combinations with and without ERVs. A building was modeled in DesignBuilder and simulated in EnergyPlus. The MEC-VAC system with ERV achieved the highest temperature gradient, wet bulb effectiveness, energy-saving potential, optimum relative humidity, and relatively lower CO2 emissions i.e., 19.7 °C, 2.2, 49%, 48%, and 499.2 kgCO2/kWh, respectively. Thus, ...
This study reports on the investigation of the performance of single and two-stage liquid and sol... more This study reports on the investigation of the performance of single and two-stage liquid and solid desiccant dehumidification systems and two-stage combined liquid and solid desiccant dehumidification systems with reference to humid climates. The research focus is on a dehumidification system capacity of 25 kW designed for room air conditioning application using the thermal models reported in the literature. RD-type silica gel and LiCl are used as solid and liquid desiccant materials, respectively. In this study, the application of proposed system for deep drying application is also explored. Condensation rate and moisture removal efficiency are chosen as performance parameters for room air conditioning application, whereas air outlet temperature is chosen as performance parameter for deep drying application. Further, for a given range of operating parameters, influences of air inlet humidity ratio, flow rate, and inlet temperature on performance parameters of the systems are inves...
Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is... more Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is explored. This is so because the broilers lack sweat glands as compared to humans and undergo panting process to mitigate their latent heat (moisture produced in the body) in the air. As a result, moisture production inside poultry house needs to be maintained to avoid any serious health and welfare complications. Several strategies such as compressor-based air-conditioning systems have been implemented worldwide to attenuate the heat stress in poultry, but these are not economical. Therefore, this study focuses on the development of low-cost and environmentally friendly improved evaporative cooling systems (DEC, IEC, MEC) from the viewpoint of heat stress in poultry houses. Thermodynamic analysis of these systems was carried out for the climatic conditions of Multan, Pakistan. The results appreciably controlled the environmental conditions which showed that for the months of April, May...
Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is... more Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is explored. This is so because the broilers lack sweat glands as compared to humans and undergo panting process to mitigate their latent heat (moisture produced in the body) in the air. As a result, moisture production inside poultry house needs to be maintained to avoid any serious health and welfare complications. Several strategies such as compressor-based air-conditioning systems have been implemented worldwide to attenuate the heat stress in poultry, but these are not economical. Therefore, this study focuses on the development of low-cost and environmentally friendly improved evaporative cooling systems (DEC, IEC, MEC) from the viewpoint of heat stress in poultry houses. Thermodynamic analysis of these systems was carried out for the climatic conditions of Multan, Pakistan. The results appreciably controlled the environmental conditions which showed that for the months of April, May...
In the 21st century, the poultry sector is a vital concern for the developing economies including... more In the 21st century, the poultry sector is a vital concern for the developing economies including Pakistan. The summer conditions of the city of Multan (Pakistan) are not comfortable for poultry birds. Conventionally, swamp coolers are used in the poultry sheds/houses of the city, which are not efficient enough, whereas compressor-based systems are not economical. Therefore, this study is aimed to explore a low-cost air-conditioning (AC) option from the viewpoint of heat stress in poultry birds. In this regard, the study investigates the applicability of three evaporative cooling (EC) options, i.e., direct EC (DEC), indirect EC (IEC), and Maisotsenko-cycle EC (MEC). Performance of the EC systems is investigated using wet-bulb effectiveness (WBE) for the climatic conditions of Multan. Heat stress is investigated as a function of poultry weight. Thermal comfort of the poultry birds is calculated in terms of temperature-humidity index (THI) corresponding to the ambient and output condi...
This study provides insights into the feasibility of a desiccant dehumidification-based Maisotsen... more This study provides insights into the feasibility of a desiccant dehumidification-based Maisotsenko cycle evaporative cooling (M-DAC) system for greenhouse air-conditioning application. Conventional cooling techniques include direct evaporative cooling, refrigeration systems, and passive/active ventilation. which are commonly used in Pakistan; however, they are either not feasible due to their energy cost, or they cannot efficiently provide an optimum microclimate depending on the regions, the growing seasons, and the crop being cultivated. The M-DAC system was therefore proposed and evaluated as an alternative solution for air conditioning to achieve optimum levels of vapor pressure deficit (VPD) for greenhouse crop production. The objective of this study was to investigate the thermodynamic performance of the proposed system from the viewpoints of the temperature gradient, relative humidity level, VPD, and dehumidification gradient. Results showed that the standalone desiccant air...
In the 21st century, the poultry sector is a vital concern for the developing economies including... more In the 21st century, the poultry sector is a vital concern for the developing economies including Pakistan. The summer conditions of the city of Multan (Pakistan) are not comfortable for poultry birds. Conventionally, swamp coolers are used in the poultry sheds/houses of the city, which are not efficient enough, whereas compressor-based systems are not economical. Therefore, this study is aimed to explore a low-cost air-conditioning (AC) option from the viewpoint of heat stress in poultry birds. In this regard, the study investigates the applicability of three evaporative cooling (EC) options, i.e., direct EC (DEC), indirect EC (IEC), and Maisotsenko-cycle EC (MEC). Performance of the EC systems is investigated using wet-bulb effectiveness (WBE) for the climatic conditions of Multan. Heat stress is investigated as a function of poultry weight. Thermal comfort of the poultry birds is calculated in terms of temperature-humidity index (THI) corresponding to the ambient and output condi...
As the world human population and industrialization keep growing, the water availability issue ha... more As the world human population and industrialization keep growing, the water availability issue has forced scientists, engineers, and legislators of water supply industries to better manage water resources. Pollutant removals from wastewaters are crucial to ensure qualities of available water resources (including natural water bodies or reclaimed waters). Diverse techniques have been developed to deal with water quality concerns. Carbon based nanomaterials, especially carbon nanotubes (CNTs) with their high specific surface area and associated adsorption sites, have drawn a special focus in environmental applications, especially water and wastewater treatment. This critical review summarizes recent developments and adsorption behaviors of CNTs used to remove organics or heavy metal ions from contaminated waters via adsorption and inactivation of biological species associated with CNTs. Foci include CNTs synthesis, purification, and surface modifications or functionalization, followed...
Temperature and humidity control are crucial in next generation greenhouses. Plants require optim... more Temperature and humidity control are crucial in next generation greenhouses. Plants require optimum temperature/humidity and vapor pressure deficit conditions inside the greenhouse for optimum yield. In this regard, an air-conditioning system could provide the required conditions in harsh climatic regions. In this study, the authors have summarized their published work on different desiccant and evaporative cooling options for greenhouse air-conditioning. The direct, indirect, and Maisotsenko cycle evaporative cooling systems, and multi-stage evaporative cooling systems have been summarized in this study. Different desiccant materials i.e., silica-gels, activated carbons (powder and fiber), polymer sorbents, and metal organic frameworks have also been summarized in this study along with different desiccant air-conditioning options. However, different high-performance zeolites and molecular sieves are extensively studied in literature. The authors conclude that solar operated desicca...
Indus Basin Irrigation System (IBIS) in Pakistan is the backbone of agriculture in the country. T... more Indus Basin Irrigation System (IBIS) in Pakistan is the backbone of agriculture in the country. The IBIS provides irrigation support to agricultural lands across the country; however, hydraulic efficiency of the water conveyance system is impacted due to seepage losses. The lining of irrigation channels is considered a potential solution for improving hydraulic efficiency. Therefore, this study explores the impact of canal lining on the hydraulic efficiency of the canals in the Punjab province of Pakistan. Overall, 14 channels/distributaries/minors (total length 226 km) were monitored in terms of hydraulic performance in different irrigation zones. Hydraulic, geometrical, and socioeconomic parameters of channel/distributaries/minors including roughness coefficient, sediments, flow velocity, wetted parameter, breaches, theft cases, bed, side slope, water surface profile, hydraulic radius, crop yield, and vegetation growth area have been experimentally observed. Obtained results have ...
Estimation of reference evapotranspiration (ETo) is a key element in water resources management a... more Estimation of reference evapotranspiration (ETo) is a key element in water resources management and crop water requirement which, in turn, affects irrigation scheduling. ETo is subject to the influence of various climatic parameters including minimum temperature (Tmin), maximum temperature (Tmax), relative humidity (RH), windspeed (WS), and sunshine hours (SH). Usually, the influence of the climatic parameters and a dominating climatic factor influencing ETo is estimated on yearly basis. However, in diverse climatic regions, ETo varies with the varying climate. Therefore, this study aims to estimate the spatiotemporal variation in the influence of the climatic parameters on ETo in Punjab, Pakistan, for the period 1950–2021, specifically focusing on decennial, annual, and monthly patterns. The study area was divided into five agroclimatic zones. The Penman–Monteith model was used to estimate ETo. The influence was assessed using geographic weighted regression (GWR) and multiscale geo...
In a water-scarce country such as Pakistan, rainfall is the third-largest source of freshwater. I... more In a water-scarce country such as Pakistan, rainfall is the third-largest source of freshwater. In most of the urban cities of the country, rainwater is mixed with sewerage and is rendered useless for managed aquifer recharge purposes. Therefore, this study investigates the rainfall potential for managed aquifer recharge in Lahore (Pakistan). The present research was designed and conducted by the Irrigation Research Institute (IRI). Three different sites were selected for rainwater sample collection across the study area (Lahore), ranging from urban to rural areas. The rainwater samples were collected and divided into three categories (direct capture, rooftop runoff, street runoff). For longer rainfall events, the effect of time on the quality of the collected rainwater samples was also studied. Spatiotemporal trends of turbidity, pH, electrical conductivity, total dissolved solids, carbonates, bicarbonates, chloride, calcium, magnesium, and hardness in the collected rainwater sampl...
This study reports on the investigation of the performance of single and two-stage liquid and sol... more This study reports on the investigation of the performance of single and two-stage liquid and solid desiccant dehumidification systems and two-stage combined liquid and solid desiccant dehumidification systems with reference to humid climates. The research focus is on a dehumidification system capacity of 25 kW designed for room air conditioning application using the thermal models reported in the literature. RD-type silica gel and LiCl are used as solid and liquid desiccant materials, respectively. In this study, the application of proposed system for deep drying application is also explored. Condensation rate and moisture removal efficiency are chosen as performance parameters for room air conditioning application, whereas air outlet temperature is chosen as performance parameter for deep drying application. Further, for a given range of operating parameters, influences of air inlet humidity ratio, flow rate, and inlet temperature on performance parameters of the systems are inves...
The present study provides insights into the energy-saving potential of a membrane energy recover... more The present study provides insights into the energy-saving potential of a membrane energy recovery ventilator (ERV) for the management of building air-conditioning loads. This study explores direct (DEC), Maisotsenko cycle (MEC) evaporative cooling, and vapor compression (VAC) systems with ERV. Therefore, this study aims to explore possible air-conditioning options in terms of temperature, relative humidity, human thermal comfort, wet bulb effectiveness, energy saving potential, and CO2 emissions. Eight different combinations of the above-mentioned systems are proposed in this study i.e., DEC, MEC, VAC, MEC-VAC, and their possible combinations with and without ERVs. A building was modeled in DesignBuilder and simulated in EnergyPlus. The MEC-VAC system with ERV achieved the highest temperature gradient, wet bulb effectiveness, energy-saving potential, optimum relative humidity, and relatively lower CO2 emissions i.e., 19.7 °C, 2.2, 49%, 48%, and 499.2 kgCO2/kWh, respectively. Thus, ...
This study reports on the investigation of the performance of single and two-stage liquid and sol... more This study reports on the investigation of the performance of single and two-stage liquid and solid desiccant dehumidification systems and two-stage combined liquid and solid desiccant dehumidification systems with reference to humid climates. The research focus is on a dehumidification system capacity of 25 kW designed for room air conditioning application using the thermal models reported in the literature. RD-type silica gel and LiCl are used as solid and liquid desiccant materials, respectively. In this study, the application of proposed system for deep drying application is also explored. Condensation rate and moisture removal efficiency are chosen as performance parameters for room air conditioning application, whereas air outlet temperature is chosen as performance parameter for deep drying application. Further, for a given range of operating parameters, influences of air inlet humidity ratio, flow rate, and inlet temperature on performance parameters of the systems are inves...
Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is... more Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is explored. This is so because the broilers lack sweat glands as compared to humans and undergo panting process to mitigate their latent heat (moisture produced in the body) in the air. As a result, moisture production inside poultry house needs to be maintained to avoid any serious health and welfare complications. Several strategies such as compressor-based air-conditioning systems have been implemented worldwide to attenuate the heat stress in poultry, but these are not economical. Therefore, this study focuses on the development of low-cost and environmentally friendly improved evaporative cooling systems (DEC, IEC, MEC) from the viewpoint of heat stress in poultry houses. Thermodynamic analysis of these systems was carried out for the climatic conditions of Multan, Pakistan. The results appreciably controlled the environmental conditions which showed that for the months of April, May...
Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is... more Poultry are one of the most vulnerable species of its kind once the temperature-humidity nexus is explored. This is so because the broilers lack sweat glands as compared to humans and undergo panting process to mitigate their latent heat (moisture produced in the body) in the air. As a result, moisture production inside poultry house needs to be maintained to avoid any serious health and welfare complications. Several strategies such as compressor-based air-conditioning systems have been implemented worldwide to attenuate the heat stress in poultry, but these are not economical. Therefore, this study focuses on the development of low-cost and environmentally friendly improved evaporative cooling systems (DEC, IEC, MEC) from the viewpoint of heat stress in poultry houses. Thermodynamic analysis of these systems was carried out for the climatic conditions of Multan, Pakistan. The results appreciably controlled the environmental conditions which showed that for the months of April, May...
In the 21st century, the poultry sector is a vital concern for the developing economies including... more In the 21st century, the poultry sector is a vital concern for the developing economies including Pakistan. The summer conditions of the city of Multan (Pakistan) are not comfortable for poultry birds. Conventionally, swamp coolers are used in the poultry sheds/houses of the city, which are not efficient enough, whereas compressor-based systems are not economical. Therefore, this study is aimed to explore a low-cost air-conditioning (AC) option from the viewpoint of heat stress in poultry birds. In this regard, the study investigates the applicability of three evaporative cooling (EC) options, i.e., direct EC (DEC), indirect EC (IEC), and Maisotsenko-cycle EC (MEC). Performance of the EC systems is investigated using wet-bulb effectiveness (WBE) for the climatic conditions of Multan. Heat stress is investigated as a function of poultry weight. Thermal comfort of the poultry birds is calculated in terms of temperature-humidity index (THI) corresponding to the ambient and output condi...
This study provides insights into the feasibility of a desiccant dehumidification-based Maisotsen... more This study provides insights into the feasibility of a desiccant dehumidification-based Maisotsenko cycle evaporative cooling (M-DAC) system for greenhouse air-conditioning application. Conventional cooling techniques include direct evaporative cooling, refrigeration systems, and passive/active ventilation. which are commonly used in Pakistan; however, they are either not feasible due to their energy cost, or they cannot efficiently provide an optimum microclimate depending on the regions, the growing seasons, and the crop being cultivated. The M-DAC system was therefore proposed and evaluated as an alternative solution for air conditioning to achieve optimum levels of vapor pressure deficit (VPD) for greenhouse crop production. The objective of this study was to investigate the thermodynamic performance of the proposed system from the viewpoints of the temperature gradient, relative humidity level, VPD, and dehumidification gradient. Results showed that the standalone desiccant air...
In the 21st century, the poultry sector is a vital concern for the developing economies including... more In the 21st century, the poultry sector is a vital concern for the developing economies including Pakistan. The summer conditions of the city of Multan (Pakistan) are not comfortable for poultry birds. Conventionally, swamp coolers are used in the poultry sheds/houses of the city, which are not efficient enough, whereas compressor-based systems are not economical. Therefore, this study is aimed to explore a low-cost air-conditioning (AC) option from the viewpoint of heat stress in poultry birds. In this regard, the study investigates the applicability of three evaporative cooling (EC) options, i.e., direct EC (DEC), indirect EC (IEC), and Maisotsenko-cycle EC (MEC). Performance of the EC systems is investigated using wet-bulb effectiveness (WBE) for the climatic conditions of Multan. Heat stress is investigated as a function of poultry weight. Thermal comfort of the poultry birds is calculated in terms of temperature-humidity index (THI) corresponding to the ambient and output condi...
As the world human population and industrialization keep growing, the water availability issue ha... more As the world human population and industrialization keep growing, the water availability issue has forced scientists, engineers, and legislators of water supply industries to better manage water resources. Pollutant removals from wastewaters are crucial to ensure qualities of available water resources (including natural water bodies or reclaimed waters). Diverse techniques have been developed to deal with water quality concerns. Carbon based nanomaterials, especially carbon nanotubes (CNTs) with their high specific surface area and associated adsorption sites, have drawn a special focus in environmental applications, especially water and wastewater treatment. This critical review summarizes recent developments and adsorption behaviors of CNTs used to remove organics or heavy metal ions from contaminated waters via adsorption and inactivation of biological species associated with CNTs. Foci include CNTs synthesis, purification, and surface modifications or functionalization, followed...
Temperature and humidity control are crucial in next generation greenhouses. Plants require optim... more Temperature and humidity control are crucial in next generation greenhouses. Plants require optimum temperature/humidity and vapor pressure deficit conditions inside the greenhouse for optimum yield. In this regard, an air-conditioning system could provide the required conditions in harsh climatic regions. In this study, the authors have summarized their published work on different desiccant and evaporative cooling options for greenhouse air-conditioning. The direct, indirect, and Maisotsenko cycle evaporative cooling systems, and multi-stage evaporative cooling systems have been summarized in this study. Different desiccant materials i.e., silica-gels, activated carbons (powder and fiber), polymer sorbents, and metal organic frameworks have also been summarized in this study along with different desiccant air-conditioning options. However, different high-performance zeolites and molecular sieves are extensively studied in literature. The authors conclude that solar operated desicca...
Uploads
Papers by Hadeed Ashraf