[go: up one dir, main page]

An Entity of Type: locomotive, from Named Graph: http://dbpedia.org, within Data Space: dbpedia.org

Peak kilovoltage (kVp) refers to the maximum high voltage applied across an X-ray tube to produce the X-rays. During X-ray generation, surface electrons are released from a heated cathode by thermionic emission. The applied voltage (kV) accelerates these electrons toward an anode target, ultimately producing X-rays when the electrons are stopped in the anode. Thus, the kVp corresponds to the highest kinetic energy of the electrons striking the target, and is proportional to the maximum photon energy of the resulting X-ray emission spectrum. In early and basic X-ray equipment, the applied voltage varies cyclically, with one, two, or more pulses per mains AC power cycle. One standard way to measure pulsating DC is its peak amplitude, hence kVp. Most modern X-ray generators apply a constant p

Property Value
dbo:abstract
  • الفلطية الذروية بالكيلو فولت (kVp) هي أقصى جهد كهربائي يمر عبر أنبوب الأشعة السينية. وهو يحدد الطاقة الحركية لـلإلكترونات المتسارعة في أنبوب الأشعة السينية، والطاقة القصوى لـطيف انبعاث الأشعة السينية. وقد يتغير الجهد الكهربائي الفعلي عبر الأنبوب. وتتحكم الفلطية الذروية في الخاصية الفوتوغرافية الناتجة والتي يطلق عليها «تباين التصوير الشعاعي» لصورة الأشعة السينية (حجم الاختلاف بين الأسود والأبيض). ويحتوي كل جزء من أجزاء الجسم على نوعٍ معين من التكوينات الخلوية التي تتطلب حزمة من الأشعة السينية التي تتميز بفلطية ذروية معينة لاختراقها. ويُذكر أن أجزاء الجسم تتميز بخاصية «تباين الهدف» (أي اختلاف التركيب الخلوي: حيث تكون بعض الأنسجة كثيفة، وبعضها غير كثيف للغاية وتوجد جميع هذه الأنسجة داخل جزء معين من الجسم). على سبيل المثال: تختلف نسب الهواء من العظام إلى العضلات في البطن عن تلك النسب في منطقة الصدر. ولذلك يكون تباين الهدف أعلى في منطقة الصدر منه في منطقة البطن. وللحصول على أكبر قدرٍ من المعلومات من تصوير الجسم، تتطلب المناطق الأعلى من حيث تباين الهدف فلطية ذروية أعلى لينتج عن ذلك صورة منخفضة التباين الإشعاعي والعكس. وعلى الرغم من أن شدة التيار الكهربائي (بالمللي أمبير/ثانية) هو العامل الأساسي للتحكم في كثافة التصوير الإشعاعي، تؤثر أيضًا الفلطية الذروية على كثافة التصوير الإشعاعي بطريقة غير مباشرة. ومع زيادة طاقة (الفلطية الذروية) شعاع الإلكترونات في أنبوب الأشعة السينية، زادت قدرة فوتونات الأشعة السينية الناشئة عن هذه الإلكترونات على اختراق خلايا الجسم والوصول إلى مستقبل الصورة (فيلم أو لوحة)؛ مما يؤدي إلى زيادة الكثافة الإشعاعية (مقارنةً بحزم الطاقة الأقل والتي قد يمتصها الجسم أثناء مرورها إلى مستقبلات الصورة). ومع ذلك، يساهم «تشتت الإشعاع» أيضًا في زيادة كثافة التصوير الإشعاعي، فكلما ارتفعت الفلطية الذروية للحزمة، ازداد التشتت. والتشتت هو الكثافة غير المرغوبة (أي الكثافة التي يتم إنشاؤها بدون جلب أية معلومات ذات صلةٍ بمستقبل الصورة). وهذا هو السبب الذي يكمن وراء عدم استخدام الفلطية الذروية بشكل أساسي للتحكم في الكثافة؛ نظرًا لتمرير الكثافة الناتجة عن ازدياد الفلطية الذروية لما هو مطلوب لاختراق جزءٍ ما، وهي تضيف فقط معلومات غير مفيدة إلى الصورة. وتؤدي زيادة شدة التيار الكهربائي إلى إنتاج المزيد من الفوتونات (الإشعاع) من طاقة الفلطية الذروية المحددة. ويكون ذلك مفيدًا عندما يتم تصوير أجزاء أكبر، نظرًا لأنها تتطلب فوتونات أكثر. وكلما ازدادت الفوتونات التي يمكنك الحصول عليها للمرور عبر نوع معين من الأنسجة (التي تتفاعل الفلطية الذروية لها على المستوى الخلوي) أدى ذلك إلى كمية متزايدة إحصائيًا من الفوتونات التي تصل إلى مستقبل الصورة. وكلما زاد عدد الفوتونات التي تمر عبر جزءٍ ما، وتصل إلى مستقبل الصورة مع المعلومات ذات الصلة، زادت أهمية الكثافة التي يتم إنشاؤها على الصورة الناتجة. وعلى العكس، يؤدي انخفاض شدة التيار إلى خفض عدد الفوتونات، مما يؤدي إلى خفض الكثافة، ولكنه يكون مفيدًا عند تصوير الأجزاء الأصغر. (ar)
  • Peak kilovoltage (kVp) refers to the maximum high voltage applied across an X-ray tube to produce the X-rays. During X-ray generation, surface electrons are released from a heated cathode by thermionic emission. The applied voltage (kV) accelerates these electrons toward an anode target, ultimately producing X-rays when the electrons are stopped in the anode. Thus, the kVp corresponds to the highest kinetic energy of the electrons striking the target, and is proportional to the maximum photon energy of the resulting X-ray emission spectrum. In early and basic X-ray equipment, the applied voltage varies cyclically, with one, two, or more pulses per mains AC power cycle. One standard way to measure pulsating DC is its peak amplitude, hence kVp. Most modern X-ray generators apply a constant potential across the X-ray tube; in such systems, the kVp and the steady-state kV are identical. kVp controls the property called "radiographic contrast" of an X-ray image (the ratio of transmitted radiation through regions of different thickness or density). Each body part contains a certain type of cellular composition which requires an X-ray beam with a certain kVp to penetrate it. The body part is said to have "subject contrast" (that is, different cellular make up: some dense, some not so dense tissues all within a specific body part). For example: bone to muscle to air ratios in the abdomen differ from those of the chest area. So the subject contrast is said to be higher in the chest than in the abdomen. In order to image the body so that the maximum information will result, higher subject contrast areas require a higher kVp so as to result in a low radiographic contrast image, and vice versa. Although the product of tube current and exposure time, measured in milliampere-seconds (mA·s), is the primary controlling factor of radiographic density, kVp also affects the radiographic density indirectly. As the energy (which is proportional to the peak voltage) of the stream of electrons in the X-ray tube increases, the X-ray photons created from those electrons are more likely to penetrate the cells of the body and reach the image receptor (film or plate), resulting in increased film density (compared to lower energy beams that may be absorbed in the body on their way to the image receptor). However, scattered X-rays also contribute to increased film density: the higher the kVp of the beam, the more scatter will be produced. Scatter adds unwanted density (that is, density that does not bring pertinent information to the image receptor). This is why kVp is not primarily used to control film density – as the density resulting from increasing kVp exceeds what is needed to penetrate a body part, it only adds useless photons to the image. Increasing mAs causes more photons (radiation) of the particular kVp energy to be produced. This is helpful when larger body parts are imaged, because they require more photons. The more photons that pass through a particular tissue type (whose kVp is interacting at the cellular level), the more photons reach the image receptor. The more photons that pass through a part and reach the image receptor with pertinent information, the more useful the film density on the resulting image. Conversely, lower mAs creates fewer photons, which will decrease film density, but is helpful when imaging smaller parts. The measurement of kVp is done by kV meter. The quality of X-ray tube depends upon the kV applied across the filament at the target. A slight change in kV affects the image significantly. Therefore, it is necessary to measure kV applied to tube accurately. (en)
dbo:wikiPageID
  • 6812233 (xsd:integer)
dbo:wikiPageLength
  • 4204 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1107853113 (xsd:integer)
dbo:wikiPageWikiLink
dbp:wikiPageUsesTemplate
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • الفلطية الذروية بالكيلو فولت (kVp) هي أقصى جهد كهربائي يمر عبر أنبوب الأشعة السينية. وهو يحدد الطاقة الحركية لـلإلكترونات المتسارعة في أنبوب الأشعة السينية، والطاقة القصوى لـطيف انبعاث الأشعة السينية. وقد يتغير الجهد الكهربائي الفعلي عبر الأنبوب. (ar)
  • Peak kilovoltage (kVp) refers to the maximum high voltage applied across an X-ray tube to produce the X-rays. During X-ray generation, surface electrons are released from a heated cathode by thermionic emission. The applied voltage (kV) accelerates these electrons toward an anode target, ultimately producing X-rays when the electrons are stopped in the anode. Thus, the kVp corresponds to the highest kinetic energy of the electrons striking the target, and is proportional to the maximum photon energy of the resulting X-ray emission spectrum. In early and basic X-ray equipment, the applied voltage varies cyclically, with one, two, or more pulses per mains AC power cycle. One standard way to measure pulsating DC is its peak amplitude, hence kVp. Most modern X-ray generators apply a constant p (en)
rdfs:label
  • فولتية ذروية (ar)
  • Peak kilovoltage (en)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
is dbo:wikiPageRedirects of
is dbo:wikiPageWikiLink of
is foaf:primaryTopic of
Powered by OpenLink Virtuoso    This material is Open Knowledge     W3C Semantic Web Technology     This material is Open Knowledge    Valid XHTML + RDFa
This content was extracted from Wikipedia and is licensed under the Creative Commons Attribution-ShareAlike 3.0 Unported License