Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum ar... more Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum are described. Considerable diagnostic delay occurred with the correct diagnosis established first at 3 and 8 months, respectively. Radiologic findings compatible with TCA such as prolonged barium retention, reflux into ileum following barium enema, and foreshortening of colon were not clearly evident initially. Both patients demonstrated multiple acquired colon diverticula which increased both in number and size during the period of observation. These diverticula are probably a late manifestation of the spastic state of the anganglionic colon. Thus demonstration of diverticula supplies a strong evidence of TCA in infants with intestinal obstruction.
In the present study, we examined the effect of a diverting colostomy on the intestinal healing o... more In the present study, we examined the effect of a diverting colostomy on the intestinal healing of colonic anastomosis in the rat. For this purpose, we created a colonic stenosis 2 days prior to the formation of a distal one-layer end-to-end anastomosis with or without a proximal double-barreled deviation colostomy in the rats. Radiological examination of anastomotic leakage was performed daily for 4 days and on day 7 after the operation. We found that anastomotic leakage was markedly increased in rats with a diverting colostomy compared to control animals; i.e. the leakage index (percentage of days with leakage during the experimental period) in colostomy rats was 29%, whereas in animals with no colostomy, the leakage index was only 7%. Interestingly, it was observed that anastomosis formation was associated with a higher mortality rate in rats with colostomy diversion (36%) compared to control animals (7%). However, there was no difference in suture holding capacity on day 7. More...
Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum ar... more Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum are described. Considerable diagnostic delay occurred with the correct diagnosis established first at 3 and 8 months, respectively. Radiologic findings compatible with TCA such as prolonged barium retention, reflux into ileum following barium enema, and foreshortening of colon were not clearly evident initially. Both patients demonstrated multiple acquired colon diverticula which increased both in number and size during the period of observation. These diverticula are probably a late manifestation of the spastic state of the anganglionic colon. Thus demonstration of diverticula supplies a strong evidence of TCA in infants with intestinal obstruction.
Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowled... more Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowledge of current practice is needed to ensure quality of care and help focus future research. The objective of this study was to examine sedation and monitoring practice in endoscopy centers internationally. This observational study included consecutive patients referred for colonoscopy at 21 centers in 11 countries. Endoscopists reported sedation and monitoring practice, using a standard questionnaire for each patient. 6004 patients were included in this study, of whom 53 % received conscious/moderate sedation during colonoscopy, 30 % received deep sedation, and 17 % received no sedation. Sedation agents most commonly used were midazolam (47 %) and opioids (33 %). Pulse oximetry was done during colonoscopy in 77 % of patients, blood pressure monitoring in 34 %, and electrocardiography in 24 %. Pulse oximetry was most commonly used for moderately sedated patients, while blood pressure monitoring and electrocardiography were used predominantly for deeply sedated patients. Sedation and monitoring use ranged from 0 % to 100 % between centers. Oxygen desaturation (</= 85 %) occurred in 5 % of patients, of whom 80 % were moderately sedated. On average, three staff members were involved in procedures. An anesthesiologist was present during 27 % of colonoscopies, and during 85 % of colonoscopies using deep sedation. Internationally, sedation and monitoring practice during colonoscopy varied widely. Moderate sedation was the most common sedation method used and electronic monitoring was used in three-quarters of patients. Deep sedation tended to be more resource-intensive, implying a greater use of staff and monitoring.
BACKGROUND: Most individuals with Helicobacter pylori infection in Western countries have no evid... more BACKGROUND: Most individuals with Helicobacter pylori infection in Western countries have no evidence of peptic ulcer disease (PUD). We therefore assessed the PiZ deficiency variant of the major plasma protease inhibitor alpha1-antitrypsin (alpha1AT) as a risk factor for PUD in H. pylori-infected individuals. METHODS: The cohort comprised 100 patients with endoscopically or surgically proven PUD (30 patients with duodenal ulcer (DU) and 70 patients with gastric ulcer (GU)) and 162 age- and sex-matched controls with PUD-negative endoscopic findings and no history of PUD. Plasma samples were screened for alpha1AT deficiency (PiZ) with an enzyme-linked immunosorbent assay (ELISA) and phenotyped by isoelectric focusing. H. pylori infection was evaluated with an IgG ELISA technique. RESULTS: Among the 262 patients 17 (6.5%) were positive for the PiZ alpha1AT deficiency, a frequency of the same magnitude as in the Swedish general population (4.7%). Of the PiZ carriers 76% (13 of 17) had H...
A negative oral contrast agent (OCA) has been long sought for, to better delineate the bowel and ... more A negative oral contrast agent (OCA) has been long sought for, to better delineate the bowel and visualise surrounding structures. Lumentin® 44 (L44) is a new OCA formulated to fill the entire small bowel. The aim of this study was to compare L44 with positive and neutral conventional OCA in abdominal computed tomography (CT). Forty-five oncologic patients were randomised to receive either L44 or one of the two comparators (MoviPrep® or diluted Omnipaque®). Abdominal CT examinations with intravenous contrast agent were acquired according to standard protocols. The studies were read independently by two senior radiologists. The mean intraluminal Hounsfield units (HU)-values of regions-of-interest (ROIs) for each subsegment of small bowel and treatment group were -404.0 HU for L44, 166.1 HU for Omnipaque®, and 16.7 HU for MoviPrep® (L44 versus Omnipaque, p < 0.001: L44 versus MoviPrep p < 0.001; Omnipaque versus MoviPrep, p = 0.003). Adverse events, only mild, using L44 were num...
Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wirele... more Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wireless capsule-enteroscopy (WCE) has already contributed significantly to the understanding of patients with obscure intestinal symptoms. Series of occult bleeders show that WCE detects lesions in 60%, whereas enterography only in 15%, and push-enteroscopy in 25%. Lesions detected are angiodysplasia in 55%, ulcerations in 14%, aphtoid lesions and erosions in 11%, tumours in 8%. Active bleeding was seen in 43%. In patients with Crohn’s disease further information on extent of disease and type of lesions is gained, mainly seen as erosions in 64%. WCE in hereditary polyposis disclosed more and bigger lesions, and in celiac enteropathy villous atrophy and scalloping of the mucous membrane is readily identified. Software to locate the capsule in the gastrointestinal tract is recently launched together with a graphic display of capsule track and transit times. Soon displays for motility and pressu...
Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wirele... more Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wireless capsule-enteroscopy (WCE) has already contributed significantly to the understanding of patients with obscure intestinal symptoms. Series of occult bleeders show that WCE detects lesions in 60%, whereas enterography only in 15%, and push-enteroscopy in 25%. Lesions detected are angiodysplasia in 55%, ulcerations in 14%, aphtoid lesions and erosions in 11%, tumours in 8%. Active bleeding was seen in 43%. In patients with Crohn’s disease further information on extent of disease and type of lesions is gained, mainly seen as erosions in 64%. WCE in hereditary polyposis disclosed more and bigger lesions, and in celiac enteropathy villous atrophy and scalloping of the mucous membrane is readily identified. Software to locate the capsule in the gastrointestinal tract is recently launched together with a graphic display of capsule track and transit times. Soon displays for motility and pressure will follow. Capsule adaptation for screening for Barrett’s esophagus and colon cancer might come true. (Less)
Journal of magnetic resonance imaging : JMRI, Aug 23, 2016
To study the feasibility and to gauge the potential clinical impact of quantifying small bowel mo... more To study the feasibility and to gauge the potential clinical impact of quantifying small bowel motility using magnetic resonance imaging (MRI) in a larger population with a spectra of gastrointestinal conditions with impaired small bowel motility. Data were gathered retrospectively from a cohort of 127 patients undergoing MR enterography (1.5 Tesla) in 2011. Cine motility sequences were processed with validated motility analysis software and a parametric motility map was generated. Regions of interests were drawn in the jejunum, ileum, and terminal ileum, and Jacobian standard deviation mean motility index' score (MIS) was calculated. Patients were divided into Crohn's disease (CD), ulcerative colitis, irritable bowel syndrome, and healthy subjects. In CD, terminal ileum motility was lower in comparison to healthy subjects (mean difference: -0.1052 arbitrary units, 95% confidence interval: -0.1981--0.0122, P = 0.018). Subgrouping of CD showed that the difference was recogniz...
Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum ar... more Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum are described. Considerable diagnostic delay occurred with the correct diagnosis established first at 3 and 8 months, respectively. Radiologic findings compatible with TCA such as prolonged barium retention, reflux into ileum following barium enema, and foreshortening of colon were not clearly evident initially. Both patients demonstrated multiple acquired colon diverticula which increased both in number and size during the period of observation. These diverticula are probably a late manifestation of the spastic state of the anganglionic colon. Thus demonstration of diverticula supplies a strong evidence of TCA in infants with intestinal obstruction.
In the present study, we examined the effect of a diverting colostomy on the intestinal healing o... more In the present study, we examined the effect of a diverting colostomy on the intestinal healing of colonic anastomosis in the rat. For this purpose, we created a colonic stenosis 2 days prior to the formation of a distal one-layer end-to-end anastomosis with or without a proximal double-barreled deviation colostomy in the rats. Radiological examination of anastomotic leakage was performed daily for 4 days and on day 7 after the operation. We found that anastomotic leakage was markedly increased in rats with a diverting colostomy compared to control animals; i.e. the leakage index (percentage of days with leakage during the experimental period) in colostomy rats was 29%, whereas in animals with no colostomy, the leakage index was only 7%. Interestingly, it was observed that anastomosis formation was associated with a higher mortality rate in rats with colostomy diversion (36%) compared to control animals (7%). However, there was no difference in suture holding capacity on day 7. More...
Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum ar... more Two infants with total colonic aganglionosis (TCA) extending into the distal part of the ileum are described. Considerable diagnostic delay occurred with the correct diagnosis established first at 3 and 8 months, respectively. Radiologic findings compatible with TCA such as prolonged barium retention, reflux into ileum following barium enema, and foreshortening of colon were not clearly evident initially. Both patients demonstrated multiple acquired colon diverticula which increased both in number and size during the period of observation. These diverticula are probably a late manifestation of the spastic state of the anganglionic colon. Thus demonstration of diverticula supplies a strong evidence of TCA in infants with intestinal obstruction.
Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowled... more Sedation and monitoring practice during colonoscopy varies between centers and over time. Knowledge of current practice is needed to ensure quality of care and help focus future research. The objective of this study was to examine sedation and monitoring practice in endoscopy centers internationally. This observational study included consecutive patients referred for colonoscopy at 21 centers in 11 countries. Endoscopists reported sedation and monitoring practice, using a standard questionnaire for each patient. 6004 patients were included in this study, of whom 53 % received conscious/moderate sedation during colonoscopy, 30 % received deep sedation, and 17 % received no sedation. Sedation agents most commonly used were midazolam (47 %) and opioids (33 %). Pulse oximetry was done during colonoscopy in 77 % of patients, blood pressure monitoring in 34 %, and electrocardiography in 24 %. Pulse oximetry was most commonly used for moderately sedated patients, while blood pressure monitoring and electrocardiography were used predominantly for deeply sedated patients. Sedation and monitoring use ranged from 0 % to 100 % between centers. Oxygen desaturation (&lt;/= 85 %) occurred in 5 % of patients, of whom 80 % were moderately sedated. On average, three staff members were involved in procedures. An anesthesiologist was present during 27 % of colonoscopies, and during 85 % of colonoscopies using deep sedation. Internationally, sedation and monitoring practice during colonoscopy varied widely. Moderate sedation was the most common sedation method used and electronic monitoring was used in three-quarters of patients. Deep sedation tended to be more resource-intensive, implying a greater use of staff and monitoring.
BACKGROUND: Most individuals with Helicobacter pylori infection in Western countries have no evid... more BACKGROUND: Most individuals with Helicobacter pylori infection in Western countries have no evidence of peptic ulcer disease (PUD). We therefore assessed the PiZ deficiency variant of the major plasma protease inhibitor alpha1-antitrypsin (alpha1AT) as a risk factor for PUD in H. pylori-infected individuals. METHODS: The cohort comprised 100 patients with endoscopically or surgically proven PUD (30 patients with duodenal ulcer (DU) and 70 patients with gastric ulcer (GU)) and 162 age- and sex-matched controls with PUD-negative endoscopic findings and no history of PUD. Plasma samples were screened for alpha1AT deficiency (PiZ) with an enzyme-linked immunosorbent assay (ELISA) and phenotyped by isoelectric focusing. H. pylori infection was evaluated with an IgG ELISA technique. RESULTS: Among the 262 patients 17 (6.5%) were positive for the PiZ alpha1AT deficiency, a frequency of the same magnitude as in the Swedish general population (4.7%). Of the PiZ carriers 76% (13 of 17) had H...
A negative oral contrast agent (OCA) has been long sought for, to better delineate the bowel and ... more A negative oral contrast agent (OCA) has been long sought for, to better delineate the bowel and visualise surrounding structures. Lumentin® 44 (L44) is a new OCA formulated to fill the entire small bowel. The aim of this study was to compare L44 with positive and neutral conventional OCA in abdominal computed tomography (CT). Forty-five oncologic patients were randomised to receive either L44 or one of the two comparators (MoviPrep® or diluted Omnipaque®). Abdominal CT examinations with intravenous contrast agent were acquired according to standard protocols. The studies were read independently by two senior radiologists. The mean intraluminal Hounsfield units (HU)-values of regions-of-interest (ROIs) for each subsegment of small bowel and treatment group were -404.0 HU for L44, 166.1 HU for Omnipaque®, and 16.7 HU for MoviPrep® (L44 versus Omnipaque, p < 0.001: L44 versus MoviPrep p < 0.001; Omnipaque versus MoviPrep, p = 0.003). Adverse events, only mild, using L44 were num...
Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wirele... more Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wireless capsule-enteroscopy (WCE) has already contributed significantly to the understanding of patients with obscure intestinal symptoms. Series of occult bleeders show that WCE detects lesions in 60%, whereas enterography only in 15%, and push-enteroscopy in 25%. Lesions detected are angiodysplasia in 55%, ulcerations in 14%, aphtoid lesions and erosions in 11%, tumours in 8%. Active bleeding was seen in 43%. In patients with Crohn’s disease further information on extent of disease and type of lesions is gained, mainly seen as erosions in 64%. WCE in hereditary polyposis disclosed more and bigger lesions, and in celiac enteropathy villous atrophy and scalloping of the mucous membrane is readily identified. Software to locate the capsule in the gastrointestinal tract is recently launched together with a graphic display of capsule track and transit times. Soon displays for motility and pressu...
Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wirele... more Since 1,5 years wireless enteroscopy with the GivenM2A-capsule has been tested clinically. Wireless capsule-enteroscopy (WCE) has already contributed significantly to the understanding of patients with obscure intestinal symptoms. Series of occult bleeders show that WCE detects lesions in 60%, whereas enterography only in 15%, and push-enteroscopy in 25%. Lesions detected are angiodysplasia in 55%, ulcerations in 14%, aphtoid lesions and erosions in 11%, tumours in 8%. Active bleeding was seen in 43%. In patients with Crohn’s disease further information on extent of disease and type of lesions is gained, mainly seen as erosions in 64%. WCE in hereditary polyposis disclosed more and bigger lesions, and in celiac enteropathy villous atrophy and scalloping of the mucous membrane is readily identified. Software to locate the capsule in the gastrointestinal tract is recently launched together with a graphic display of capsule track and transit times. Soon displays for motility and pressure will follow. Capsule adaptation for screening for Barrett’s esophagus and colon cancer might come true. (Less)
Journal of magnetic resonance imaging : JMRI, Aug 23, 2016
To study the feasibility and to gauge the potential clinical impact of quantifying small bowel mo... more To study the feasibility and to gauge the potential clinical impact of quantifying small bowel motility using magnetic resonance imaging (MRI) in a larger population with a spectra of gastrointestinal conditions with impaired small bowel motility. Data were gathered retrospectively from a cohort of 127 patients undergoing MR enterography (1.5 Tesla) in 2011. Cine motility sequences were processed with validated motility analysis software and a parametric motility map was generated. Regions of interests were drawn in the jejunum, ileum, and terminal ileum, and Jacobian standard deviation mean motility index' score (MIS) was calculated. Patients were divided into Crohn's disease (CD), ulcerative colitis, irritable bowel syndrome, and healthy subjects. In CD, terminal ileum motility was lower in comparison to healthy subjects (mean difference: -0.1052 arbitrary units, 95% confidence interval: -0.1981--0.0122, P = 0.018). Subgrouping of CD showed that the difference was recogniz...
Uploads
Papers by Thomas Fork