While many school retrofits in Korea tend to focus on energy savings, some school operation pract... more While many school retrofits in Korea tend to focus on energy savings, some school operation practices and policies in the field may cause indoor air quality issues. This study aims to analyze the indoor air quality impact when selected measures of the energy retrofit package are applied to classrooms in a real operation context with actual airflow and contaminant transport characteristics. The selected measures included replacement of envelope windows/doors/hallway-side windows, more airtight enclosures as a byproduct of adding envelope insulation, ventilation systems and air purifiers under various operating conditions, and natural ventilation. Actual classrooms with the ages of 10, 20, and 80 years were selected. Their CONTAM base models were calibrated with the measured airflow and contaminant transport variables per American Society for Testing and Materials (ASTM) D5157. The near-open-air hallways and frequent door opening made ambient PM2.5 in the hallways, which initially ori...
School retrofitting should aim to not only improve its energy performance, but also maintain a go... more School retrofitting should aim to not only improve its energy performance, but also maintain a good IAQ. An optimal combination of retrofitting measures must be selected by considering the transient state changes of the outdoor and built environments. Although a simulation is an effective platform to evaluate a combination of the retrofitting measure candidates, there is a general lack of practical methods for practitioners to collect the field data and prepare a reliable IAQ baseline model within a project timeline. This study suggests a suite of tools to generate a classroom IAQ baseline, which includes standardized diagnostic scenarios based on common retrofitting practices and measurement protocols of classroom IAQs; the diagnostic scenarios intend to quantify the dilution and filtration capabilities of classrooms through deposition, infiltration, and natural/mechanical ventilations when a high concentration is observed; the first principle model is developed to normalize the me...
Energy Efficient Building (EEB) design decisions that have traditionally been made in the later s... more Energy Efficient Building (EEB) design decisions that have traditionally been made in the later stages of the design process now often need to be made as early as the feasibility analysis stage. However, at this very early stage, the design frame does not yet provide sufficient details for accurate simulations to be run. In addition, even if the decision-makers consider an exhaustive list of options, the selected design may not be optimal, or carefully considered decisions may later need to be rolled back. At this stage, design exploration is much more important than evaluating the performance of alternatives, thus a more transparent and interpretable design support model is more advantageous for design decision-making. In the present study, we develop an EEB design decision-support model constructed by a transparent meta-model algorithm of simulations that provides reasonable accuracy, whereas most of the literature used opaque algorithms. The conditional inference tree (CIT) algor...
An integrated geothermal system in which heat pumps for air conditioning and hot water both share... more An integrated geothermal system in which heat pumps for air conditioning and hot water both share the same ground loop was proposed in our previous study. Although this system produced electricity savings of 15% compared to a conventional system in which the two heat pumps operated on their own ground loop, practical requirements regarding further lowering the operation cost of the integrated geothermal system and the possibility of the energy savings being low during winter initiated further investigation into potential energy conservation measures at no initial cost increase, if possible. Outdoor reset control for hot water supply and sequential heat pump operation, both of which could be included at no extra cost, were subsequently targeted as potential measures for greater electricity savings and economic feasibility. When these measures were incorporated into the integrated geothermal system, electricity savings of approximately 25% during the heating season compared to the con...
We propose an integrated geothermal system that consists of air-conditioning and hot water servic... more We propose an integrated geothermal system that consists of air-conditioning and hot water service ground source heat pumps, both of which share a ground water loop. The proposed system increases the COP of the service hot water ground source heat pump by recovering the condensation heat of the air-conditioning ground source heat pump as an evaporator heat source for the hot water service ground source heat pump. Eventually this integration expands the scope and capacity of the evaporator source in addition to the underground water of heat exchangers, which also leads to increase the COP of the air-conditioning ground source heat pump. The integrated geothermal heat pump system was installed in a hotel, and then data were measured for a limited period due to the hotel’s ongoing business activities. A TRNSYS simulation model has been developed as a baseline, and the baseline has been calibrated with the measured data. By running one-year simulations, it turns out that the annual elec...
Guidelines for isolation rooms in hospitals require keeping these rooms at negative pressure diff... more Guidelines for isolation rooms in hospitals require keeping these rooms at negative pressure differential, but the guidelines do not impose a particular ventilation strategy how to achieve this. In principle, one could use variable ventilation regimes responding to interventions that cause a potential contamination risk such as the opening of doors. The variable ventilation regime would temporarily increase the volume offset and hence induce a higher negative pressure differential, whereas during other times the negative pressure differential would be kept at an acceptable minimum. In practice, however, VAV boxes (i.e. damper) are often set to deliver constant air volume. In this paper an adaptive VAV operation is introduced in response to the complaint that current operation is not adequate as it leads to excessive fan energy consumption. The paper evaluates the current practice while demonstrating efficiencies of the adaptive VAV operation, and supporting a rational selection of v...
While many school retrofits in Korea tend to focus on energy savings, some school operation pract... more While many school retrofits in Korea tend to focus on energy savings, some school operation practices and policies in the field may cause indoor air quality issues. This study aims to analyze the indoor air quality impact when selected measures of the energy retrofit package are applied to classrooms in a real operation context with actual airflow and contaminant transport characteristics. The selected measures included replacement of envelope windows/doors/hallway-side windows, more airtight enclosures as a byproduct of adding envelope insulation, ventilation systems and air purifiers under various operating conditions, and natural ventilation. Actual classrooms with the ages of 10, 20, and 80 years were selected. Their CONTAM base models were calibrated with the measured airflow and contaminant transport variables per American Society for Testing and Materials (ASTM) D5157. The near-open-air hallways and frequent door opening made ambient PM2.5 in the hallways, which initially ori...
School retrofitting should aim to not only improve its energy performance, but also maintain a go... more School retrofitting should aim to not only improve its energy performance, but also maintain a good IAQ. An optimal combination of retrofitting measures must be selected by considering the transient state changes of the outdoor and built environments. Although a simulation is an effective platform to evaluate a combination of the retrofitting measure candidates, there is a general lack of practical methods for practitioners to collect the field data and prepare a reliable IAQ baseline model within a project timeline. This study suggests a suite of tools to generate a classroom IAQ baseline, which includes standardized diagnostic scenarios based on common retrofitting practices and measurement protocols of classroom IAQs; the diagnostic scenarios intend to quantify the dilution and filtration capabilities of classrooms through deposition, infiltration, and natural/mechanical ventilations when a high concentration is observed; the first principle model is developed to normalize the me...
Energy Efficient Building (EEB) design decisions that have traditionally been made in the later s... more Energy Efficient Building (EEB) design decisions that have traditionally been made in the later stages of the design process now often need to be made as early as the feasibility analysis stage. However, at this very early stage, the design frame does not yet provide sufficient details for accurate simulations to be run. In addition, even if the decision-makers consider an exhaustive list of options, the selected design may not be optimal, or carefully considered decisions may later need to be rolled back. At this stage, design exploration is much more important than evaluating the performance of alternatives, thus a more transparent and interpretable design support model is more advantageous for design decision-making. In the present study, we develop an EEB design decision-support model constructed by a transparent meta-model algorithm of simulations that provides reasonable accuracy, whereas most of the literature used opaque algorithms. The conditional inference tree (CIT) algor...
An integrated geothermal system in which heat pumps for air conditioning and hot water both share... more An integrated geothermal system in which heat pumps for air conditioning and hot water both share the same ground loop was proposed in our previous study. Although this system produced electricity savings of 15% compared to a conventional system in which the two heat pumps operated on their own ground loop, practical requirements regarding further lowering the operation cost of the integrated geothermal system and the possibility of the energy savings being low during winter initiated further investigation into potential energy conservation measures at no initial cost increase, if possible. Outdoor reset control for hot water supply and sequential heat pump operation, both of which could be included at no extra cost, were subsequently targeted as potential measures for greater electricity savings and economic feasibility. When these measures were incorporated into the integrated geothermal system, electricity savings of approximately 25% during the heating season compared to the con...
We propose an integrated geothermal system that consists of air-conditioning and hot water servic... more We propose an integrated geothermal system that consists of air-conditioning and hot water service ground source heat pumps, both of which share a ground water loop. The proposed system increases the COP of the service hot water ground source heat pump by recovering the condensation heat of the air-conditioning ground source heat pump as an evaporator heat source for the hot water service ground source heat pump. Eventually this integration expands the scope and capacity of the evaporator source in addition to the underground water of heat exchangers, which also leads to increase the COP of the air-conditioning ground source heat pump. The integrated geothermal heat pump system was installed in a hotel, and then data were measured for a limited period due to the hotel’s ongoing business activities. A TRNSYS simulation model has been developed as a baseline, and the baseline has been calibrated with the measured data. By running one-year simulations, it turns out that the annual elec...
Guidelines for isolation rooms in hospitals require keeping these rooms at negative pressure diff... more Guidelines for isolation rooms in hospitals require keeping these rooms at negative pressure differential, but the guidelines do not impose a particular ventilation strategy how to achieve this. In principle, one could use variable ventilation regimes responding to interventions that cause a potential contamination risk such as the opening of doors. The variable ventilation regime would temporarily increase the volume offset and hence induce a higher negative pressure differential, whereas during other times the negative pressure differential would be kept at an acceptable minimum. In practice, however, VAV boxes (i.e. damper) are often set to deliver constant air volume. In this paper an adaptive VAV operation is introduced in response to the complaint that current operation is not adequate as it leads to excessive fan energy consumption. The paper evaluates the current practice while demonstrating efficiencies of the adaptive VAV operation, and supporting a rational selection of v...