Searching for just a few words should be enough to get started. If you need to make more complex queries, use the tips below to guide you.
Article type: Research Article
Authors: Zhang, Jiaruia | Wang, Bod | Liu, Shiyangb; c; * | Zhong, Xinghonga | Chen, Huiqiangb; c
Affiliations: [a] Sichuan Lehan Expressway Co., Ltd., Sichuan, China | [b] College of Civil Engineering, Chongqing Jiaotong University, Chongqing, China | [c] State Key Laboratory of Mountain Bridge and Tunnel Engineering, Chongqing Jiaotong University, Chongqing, China | [d] Sichuan Tibet Expressway Co., Ltd., Chengdu, Sichuan, China
Correspondence: [*] Corresponding author: Shiyang Liu, College of Civil Engineering, Chongqing Jiaotong University, Chongqing 400074, China. E-mail: [email protected].
Abstract: The blocking of tunnel drainage pipe caused by crystals from groundwater calcification is prone to bring about lining cracking and water leakage. In this paper, in order to prevent tunnel drainage pipes from the crystallization, this study proposed a method to prevent the binding of Yin and Yang ions based on the alternating electric field. For the purpose of concluding the crystallization rules of drainage pipes and verifying the feasibility of this method, an indoor orthogonal test was adopted to study the crystallization rules and anti-crystallization efficiency of three drainage pipes under three alternating electric fields at three voltages (6 V, 9 V, 12 V) and at three flows (34.7 ml/s, 76.9 ml/s and 192.0 ml/s). The results showed that: During the test, all the three voltages can reduce the crystallization of drainage pipes, and the anti-crystallization efficiency of all the three tested pipes was optimal at 6 V under each of three alternating electric fields, reaching 22%, 25%, 7%, respectively. Case 2 had the best anti-crystallization effect at 6 V. The reason is that, at 6 V, the crystals had the loosest and minimum grains and the largest interplanar spacing, so they were inclined to be discharged through the pipe under the water flow. At 34.7 ml/s, Case 2 had the best anti-crystallization effect at 12 V; At 76.9 ml/s and 192.0 ml/s, Case 2 had the best anti-crystallization effect at 6 V. The alternating electric field can prevent the tunnel drainage pipe from crystallization and blocking, and different drainage pipes in the alternating electric fields should be selected based on according to the groundwater in tunnel.
Keywords: Karst tunnel, pipe blocked by crystals, alternating electric field, crystallization prevention
DOI: 10.3233/JCM-225979
Journal: Journal of Computational Methods in Sciences and Engineering, vol. 22, no. 3, pp. 737-747, 2022
IOS Press, Inc.
6751 Tepper Drive
Clifton, VA 20124
USA
Tel: +1 703 830 6300
Fax: +1 703 830 2300
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
IOS Press
Nieuwe Hemweg 6B
1013 BG Amsterdam
The Netherlands
Tel: +31 20 688 3355
Fax: +31 20 687 0091
[email protected]
For editorial issues, permissions, book requests, submissions and proceedings, contact the Amsterdam office [email protected]
Inspirees International (China Office)
Ciyunsi Beili 207(CapitaLand), Bld 1, 7-901
100025, Beijing
China
Free service line: 400 661 8717
Fax: +86 10 8446 7947
[email protected]
For editorial issues, like the status of your submitted paper or proposals, write to [email protected]
如果您在出版方面需要帮助或有任何建, 件至: [email protected]