[go: up one dir, main page]

A flow injection electrospray ionization tandem mass spectrometric method for the simultaneous measurement of trimethylamine and trimethylamine N-oxide in urine

J Mass Spectrom. 2008 Apr;43(4):495-9. doi: 10.1002/jms.1339.

Abstract

Key metabolites for the diagnosis of the genetic disorder trimethylaminuria are trimethylamine (TMA) and trimethylamine N-oxide (TMAO). A rapid, automatable flow injection ESI-MS/MS method for their measurement in urine has been developed. The TMA was derivatized with ethyl bromoacetate to form ethyl betaine bromide. The 2 min ESI-MS/MS analysis employed four multiple reaction monitoring (MRM) ion pairs for derivatized TMA (146.1, 118.1), derivatized (2)H(9)-TMA (155.1, 127.1), TMAO (76.1, 58.1) and (2)H(9)-TMAO (85.1, 66.1). In control urine samples (n = 27) referred for suspected metabolic problems TMA was 0.11-1.19 mmol/mol creatinine, TMAO was 13.5-181 mmol/mol creatinine and the TMA/TMAO ratio was 0.0025-0.055. In five patients with diagnosed trimethylaminuria, TMA was 5.3-230 mmol/mol creatinine, TMAO was 0.36-607 mmol/mol creatinine and the TMA/TMAO ratio was 0.20-134.

MeSH terms

  • Humans
  • Metabolism, Inborn Errors / diagnosis
  • Metabolism, Inborn Errors / urine*
  • Methylamines / analysis
  • Methylamines / urine*
  • Odorants
  • Spectrometry, Mass, Electrospray Ionization / methods*

Substances

  • Methylamines
  • trimethyloxamine
  • trimethylamine